Acil serviste intravenöz sıvı verilmesi planlanan hastalarda sıvı yanıtlılığını öngörmede ultrasonografik inferior vena kava, sol ventrikül çıkış yolu ve ana karotis arter ölçümlerinin karşılaştırılması
Comparison of sonographic measurements of inferior vena cava, left ventricular outflow tract and common carotid artery in patients planned to be given iv fluid for prediction of fluid responsiveness in emergency department
- Tez No: 683184
- Danışmanlar: DOÇ. DR. FUNDA KARBEK AKARCA
- Tez Türü: Tıpta Uzmanlık
- Konular: İlk ve Acil Yardım, Emergency and First Aid
- Anahtar Kelimeler: Acil servis-hastane, Karotis arterleri, Sıvı tedavisi, Ultrasonografi, Vena cava inferior, Ventriküler fibrilasyon, Emergency service-hospital, Carotid arteries, Fluid therapy, Ultrasonography, Vena cava inferior, Ventricular fibrillation
- Yıl: 2021
- Dil: Türkçe
- Üniversite: Ege Üniversitesi
- Enstitü: Tıp Fakültesi
- Ana Bilim Dalı: Acil Tıp Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Bu çalışmada acil serviste spontan soluyan, 500 cc IV bolus sıvı uygulanması kararı verilen hastalarda; pasif bacak kaldırma (PBK) manevrası ve sıvı bolusu ile sağlanan ultrasonografik hız zaman integrali (VTI), atım hacmi (SV), debi (CO), inferior vena kava kollapsibilite indeksi (İVKKİ), düzeltilmiş karotis akış zamanı (cCFT), karotis kan akışı (CBF) ve elektrokardiyografik akış zamanı (EKGFT) ölçümlerindeki değişikliklerin sıvı yanıtlılığını öngörmedeki başarılarının karşılaştırılması amaçlanmıştır. Gereç ve Yöntem: Prospektif, gözlemsel ve metodolojik nitelikteki bu çalışma Ege Üniversitesi Tıp Fakültesi (EÜTF) Acil Servis hasta bakım alanlarında, Ocak 2020 – Eylül 2020 tarihleri arasında gerçekleştirilmiştir. Acil servise başvuran 18 yaş üstü, hekimi tarafından 500 cc IV bolus %0,9 NaCl solüsyonu verilmesi planlanan hastalar çalışmaya dahil edilmiştir. Çalışmaya katılan hastalara sıvı bolusundan önce ve sonra PBK uygulanmış olup; PBK öncesi ve sonrası VTI, SV, CO, İVKKİ, cCFT, CBF, EKGFT ölçümleri yapılmış olup, ölçümler ve ölçüm süreleri olgu rapor formuna kaydedilmiştir. Bulgular: Çalışmaya 94 hasta seçildi. 1 hasta aort çapının 4 cm'den büyük olması nedeniyle, 3 hasta apikal 5 boşluk penceresinin görüntülenememesi nedeniyle, 11 hasta VTI ölçümleri yorumlanamadığı için çalışmadan çıkarılarak analizler 79 hasta ile yapıldı. Sıvı bolusu sonrası VTI değerlerinde %15 ve üzeri artış olanlar (n=20, %25) sıvı yanıtlı olarak değerlendirildi. Yaş, cinsiyet, sıvı verilme süresi, boy, ağırlık ve toplam vücut suları (TVS) açısından, sıvı yanıtlı ve yanıtsız grupta bir fark saptanmadı. Sıvı yüklemesi sonucu oluşan VTI değerlerindeki değişim ile; vital parametreler, cCFT, CBF ve EKGFT'deki değişimler arasında korelasyon gözlenmedi. İVKKİ ile sıvı bolusuna karşı oluşan VTI değişimi arasında düşük-orta derece korelasyon saptandı (r=0,35; p<0,05). PBK ve sıvı bolusu ile oluşan VTI değişimleri arasında orta dereceli korelasyon görüldü (r=0,58; p<0,001). ROC analizi ile yapılan değerlendirme sonucunda; PBK ile oluşan VTI değişiminin sıvı yanıtlılığını öngörmede tanısal değerinin (AUC: 0,82; %95GA: 0,70-0,94; p<0,001), İVKKİ'nin tanısal değerinden (AUC: 0,69; %95GA: 0,56-0,81; p=0,018) daha yüksek olduğu saptandı. PBK sonrası VTI ölçümü 90 sn. içinde yapılan hasta grubunda (n=58) sağlanan TVS'na göre normalize edilen VTI değişiminin sıvı yanıtlılığını göstermede en yüksek tanısal değere (AUC: 0,92; %95GA: 0,84-0,99; p<0,001) sahip olduğu görülmüştür. Sonuç: PBK ile sağlanan VTI değişimi ile 500cc sıvı bolusu sonrası oluşan VTI değişimi arasında orta dereceli korelasyon saptanmıştır. PBK sonrası VTI ölçümünün 90 sn. içinde yapılması ve oluşan değişimlerin TVS'na göre normalize edilmesi PBK ile sağlanan VTI değişiminin sıvı yanıtlılığını öngörme başarısını arttırmaktadır. İVKKİ sıvı yanıtını değerlendirmede düşük derecede başarı gösterirken cCFT, CBF ve EKGFT ölçümleri ise yetersiz kalmıştır.
Özet (Çeviri)
Objectives: In the present study, we aimed to see the accuracy of ultrasonographic velocity time integral (VTI), stroke volume (SV), inferior vena cava collapsibility index(IVCCI), cardiac output (CO), corrected carotid systolic flow time (cCFT), carotid blood flow (CBF) and corrected flow time via electrocardiography (ECGFT) measurements in detecting fluid responsiveness after administration of passive leg raising (PLR) and fluid therapy on patients admitted to emergency department with spontaneous breathing and 500 ml IV fluid administered for treatment. Methods: The current single-center prospective, observational study was conducted in Department of Emergency Medicine, Ege University from January to September 2020. The inclusion criteria were: age ≥18 years, spontaneously breathing, and had ordered 500 ml 0.9% NaCl fluid replacement by the treating physician. Before and after fluid administration PLR maneuver was performed. VTI, SV, CO, IVCCI, cCFT, CBF, ECGFT were measured and recorded during the procedure. Results: A total of 94 patients were screened for inclusion. Among them, 15 patients were excluded because 3 patients did not have appropriate echocardiographic views, one patient had >4 cm aortic diameter, 11 patients had uninterpretable measurements. Among the included 79 patients were classified according to their hemodynamic response to fluid administration. Responders had a VTI increase of at least 15%. There were no statistically significant differences in age, sex, height, weight, duration of measurements, and total body water (TBW) between the responders and non-responders. Changes in VTI are not correlated with vital signs, cCFT, CBF, and ECGFT after fluid challenge. A weak correlation was found between IVCCI and VTI changes after fluid challenge (r=0,35; p<0,05). The VTI changes induced by PLR correlated moderately with VTI changes after fluid challenge (r=0,58; p<0,001). With a receiving operating characteristics (ROC) curve, VTI changes induced by PLR have better predictive value on determining fluid responsiveness (AUC: 0,82; %95CI: 0,70-0,94; p<0,001) than IVCCI (AUC: 0,69; %95CI: 0,56-0,81; p=0,018). The best measurement to predict fluid responsiveness was found PLR induced VTI changes normalized by TBW in patients that measurement performed within 90 seconds (AUC: 0,92; %95CI: 0,84-0,99; p<0,001). Conclusions: A moderate correlation was found between VTI changes induced by PLR and VTI changes after 500 ml fluid administration. Measurement of VTI that was performed within 90 seconds after PLR and normalized by TBW increase the accuracy of PLR induced VTI changes measurement to predict fluid responsiveness. IVCCI had low accuracy for predicting fluid responsiveness while cCFT, CBF, and ECGFT were found inadequate.
Benzer Tezler
- Perfüzyon indeksi ve pletismografik değişkenlik indeksi ölçütlerinin volüm değişikliğini öngörme yeteneklerinin değerlendirilmesi
Evaluation of the ability of perfusion index and pleth variablity index to predict volume changes
ELİF DİLEK ÇAKAL
Tıpta Uzmanlık
Türkçe
2016
İlk ve Acil YardımEge ÜniversitesiAcil Tıp Ana Bilim Dalı
DOÇ. DR. MURAT ERSEL
- 1985-1986 yıllarında Polatlı Devlet Hastanesine kaza nedeniyle başvuranların incelenmesi
Başlık çevirisi yok
FERHAN ŞENOL
Yüksek Lisans
Türkçe
1986
İlk ve Acil YardımGazi ÜniversitesiKazaların Çevresel ve Teknik Araştırması Ana Bilim Dalı (disiplinlerarası)
DOÇ. DR. HİKMET PEKCAN
- Organize sanayi bölgelerinde iş güvenliği sorunlarının teknik ve bilimsel araştırılmasında bir yöntem önerisi
Başlık çevirisi yok
MEHMET ALİ YILDIRIM
Yüksek Lisans
Türkçe
1986
Çalışma Ekonomisi ve Endüstri İlişkileriGazi ÜniversitesiKazaların Çevresel ve Teknik Araştırması Ana Bilim Dalı (disiplinlerarası)
DOÇ. DR. İBRAHİM BOYNUKALIN
- Türkiye'de trafik kazalarının epidemiyolojisi
Başlık çevirisi yok
HARUN KARACA
Yüksek Lisans
Türkçe
1985
UlaşımGazi ÜniversitesiKazalarda Acil Yardım ve Rehabilitasyon Ana Bilim Dalı
DOÇ. DR. HİKMET PEKCAN
- Türkiye'de trafik kazalarının nedenleri ve acil yardım organizasyonu
Başlık çevirisi yok
VEYSEL HAVUÇ
Yüksek Lisans
Türkçe
1986
UlaşımGazi ÜniversitesiAcil Yardım ve Rehabilitasyon Ana Bilim Dalı
PROF. DR. ÖVSEV DÖRTLEMEZ