Yeni sürmüş çürüksüz daimi birinci molar dişlerde farklı içerikli fissür örtüleme materyallerinin klinik etkinliklerinin değerlendirilmesi
Clinical efficacy of different fissur sealant materials in the newly erupted non-carious first permanent molars
- Tez No: 673770
- Danışmanlar: DOÇ. DR. MERVE AKÇAY
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Fissür örtücü, geleneksel cam iyonomer, giomer, lazer floresans, rezin modifiye cam iyonomer, sürmekte olan dişler, Azı dişleri, Cam iyonomer çimentoları, Diş çıkarma, Dişler, Lazerler, Çukur ve fissür örtücüler, Conventional glass ionomer, fissure sealant, giomer, laser fluorescence, newly erupted teeth, resin modified glass ionomer, Molar, Glass ionomer cements, Dentition, Teeth, Lasers, Pit and fissure sealants
- Yıl: 2021
- Dil: Türkçe
- Üniversite: İzmir Katip Çelebi Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Pedodonti Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Bu çalışmanın amacı, sürmekte olan çürüksüz daimi birinci büyük azı dişlerinin fissür örtülemesinde kullanılan iki farklı yapıdaki rezin modifiye cam iyonomer (Fuji II LC; Clinpro XT Varnish) ve giomer içerikli fissür örtücü materyallerinin (Beautifil Flow), cam iyonomer içerikli fissür örtücü materyaliyle (Fuji Triage) ve birbirleriyle klinik retansiyon oranları, kenar adaptasyonu, kenar renklenmesi ve sekonder çürük oluşumu açısından karşılaştırılmasıdır. Gereç ve Yöntem: Bu randomize kontrollü, tek kör, bölünmüş ağız tasarımlı çalışmaya, yaşları 5-9 arasında değişen ve alt çenesinde iki adet, çürüksüz sürmekte olan daimi birinci büyük azı dişi bulunan 182 hastaya ait 384 adet diş dahil edildi. ICDAS II sınıflandırmasına göre 0 ve 1 kodlarına sahip dişler ve lazer floresans değerlendirmesine göre 0-13 arasında değer veren dişler araştırma kapsamına alındı. Çalışmaya dâhil edilen hastalar, Grup 1; Fuji II LC/Fuji Triage (Kontrol) (62 hasta), Grup 2; Clinpro XT Varnish/Fuji Triage (Kontrol) (60 hasta), Grup 3; Beautifil Flow/Fuji Triage (Kontrol) (60 hasta) olacak şekilde üç ana gruba ayrıldı. Klinik uygulamalar sonrası dişler 6. 12. ve 18. aylarda sürmekte olan dişlerde modifiye USPHS kriterleri kullanılarak retansiyon, kenar adaptasyonu, kenar renklenmesi ve sekonder çürük oluşumu açısından, ayrıca lazer floresans yöntem kullanılarak remineralizasyon etkisi açısından değerlendirildi. Okluzal ve bukkal yüzeylerde değerlendirmeler ayrı olarak gerçekleştirildi. Çalışma kapsamında yapılan tüm klinik değerlendirmeler, körleştirilmiş iki farklı araştırmacı tarafından birbirinden bağımsız ve habersiz olarak gerçekleştirildi. Elde edilen veriler istatistiksel olarak analiz edildi (α=0,05). Bulgular: Çalışmanın retansiyon sonuçları incelendiğinde: materyallerin okluzal yüzeylerdeki başarı oranları Grup 1'de Fuji II LC için %93,6, Fuji Triage için %66 (p=0,001); Grup 2'de Clinpro XT Varnish için %56,8, Fuji Triage için %77,3 (p=0,070); Grup 3'te Beautifil Flow için %95,7, Fuji Triage için %67,4 (p=0,001) 153 olarak belirlendi. Materyallerin bukkal yüzeylerdeki başarı oranları Grup 1'de Fuji II LC için %85,1, Fuji Triage için %46,8 (p<0,001); Grup 2'de Clinpro XT Varnish için %43,2, Fuji Triage için %77 (p=0,005); Grup 3'te Beautifil Flow için %67,4, Fuji Triage için %65,2 (p>0,05) olarak belirlendi. Kenar adaptasyonuna ait bulgular incelendiğinde okluzal yüzeylerde; Grup 1 ve Grup 2'de uygulanan materyaller arasında fark saptanmazken, Grup 3'te Beautifil Flow ve Fuji Triage arasındaki fark anlamlı bulundu (p=0,017). Sekonder çürük ve renklenme parametreleri incelendiğinde, tüm materyaller başarılı bulundu. Materyallerin okluzal yüzeylerde retansiyon oranı yönünden 18. ay sonundaki kümülatif yaşam yüzdesi Fuji II LC materyali için %95,7; Clinpro XT Varnish materyali için %50,5; Beautifil Flow materyali için %95,7; Fuji Triage materyali içinse %60,4 olarak bulundu. Materyaller kümülatif olarak değerlendirildiğinde, 18 ayın sonundaki okluzal/bukkal yüzeylerdeki retansiyon oranlarının karşılaştırılmasında sadece Beautifil Flow materyalinde iki yüzey arasındaki fark istatistiksel olarak anlamlı bulundu (p=0,001). Lazer floresans yöntemi kümülatif olarak değerlendirildiğinde, sadece Fuji Triage materyalinin DIAGNOdent ölçüm ortalamalarını zamana göre anlamlı derecede düşürdüğü belirlendi (p<0,001). Cohen'in Kappa testine göre, birinci ve ikinci gözlemcinin kendi içinde uyumu sırasıyla 0,90 ve 0,93; gözlemciler arası uyum ise 0,85 olarak hesaplandı. Sonuç: Sürmekte olan daimi azı dişlerinde rezin modifiye cam iyonomer içerikli Fuji II LC materyalinin uygulanan diğer materyallere göre retansiyon yönünden daha başarılı olduğu görüldü. Ayrıca cam iyonomer içerikli Fuji Triage materyalinin düşük retansiyon oranları göstermesine rağmen remineralizasyon etkisinin diğer materyallere göre daha yüksek olduğu belirlendi.
Özet (Çeviri)
Objective: The aim of this study is to compare the clinical retention rates, marginal adaptation, marginal discoloration and secondary caries formation of two different types of resin-modified glass ionomers (Fuji II LC; Clinpro XT Varnish) and giomercontaining fissure sealant materials (Beautifil Flow) with glass ionomer-containing fissure sealant material (Fuji Triage) used on newly erupted non-carious first permanent molars as a fissure sealant. Materials and Methods: This randomized controlled, single-blinded, split-mouth designed clinical trial included, 384 teeth belonging to 182 patients aged between 5 to 9 years old, who had two newly erupted mandibular permanent first molars. Teeth with codes 0 and 1 according to ICDAS II classification and with values between 0- 13 depending on laser fluorescence evaluation were included in the study. Patients included in the study were divided into 3 groups: Group 1; Fuji II LC/Fuji Triage (Control) (62 patients), Group 2; Clinpro XT Varnish/Fuji Triage (Control) (60 patients), Group 3; Beautifil Flow/Fuji Triage (Control) (60 patients). After clinical applications, all samples were evaluated in terms of retention, marginal adaptation, marginal discoloration and for secondary caries formation using modified USPHS criteria in 6th, 12th and 18th months. Also samples were evaluated in terms of remineralization effect using the laser fluorescence method. Evaluations on occlusal and buccal surfaces were performed separately. All clinical evaluations were performed by two blind observers. The data were analyzed statistically (α=0.05). Results: The retention results of the study were examined and the success rates of materials on occlusal surfaces were 93.6% for Fuji II LC and 66% for Fuji Triage in Group 1 (p=0.001); 56.8% for Clinpro XT Varnish and 77.3% for Fuji Triage in Group 2 (p=0.070); 95.7% for Beautifil Flow and 67.4% for Fuji Triage in Group 3 (p=0.001). Success rates of materials on buccal surfaces were 85.1% for Fuji II LC and 46.8% for Fuji Triage in Group 1 (p<0.001); 43.2% for Clinpro XT Varnish and 77% for Fuji Triage in Group 2 (p=0.005); 67.4% for Beautifil Flow and 65.2% for 155 Fuji Triage in Group 3 (p>0.05). When the findings of marginal adaptation were examined, there were no difference between the materials applied in Group 1 and Group 2. However, the difference between Beautifil Flow and Fuji Triage was found significant in Group 3 (p=0.017) on occlusal surface. Secondary caries and marginal discolaration parameters were examined and all materials were found successful. The cumulative survival rate was found to be 95.7% for Fuji II LC; 50.5% for Clinpro XT Varnish; 95.7% for Beautifil Flow; 60.4% for Fuji Triage in terms of retention rate on occlusal surfaces of the materials at the end of the 18th month. When the materials were evaluated cumulatively, the difference between the occlusal/buccal surface retention rates were found to be statistically significant only in the Beautifil Flow material at the end of 18 months (p=0.001). Laser fluorescence method was evaluated cumulatively and it was determined that only Fuji Triage material significantly reduced the DIAGNOdent measurement averages over time (p<0.001). The intra-observer agreement between the two examiners was 0.90 and 0.93. The inter-observer agreement was 0.85 for Cohen's Kappa. Conclusion: It was observed that the resin modified glass ionomers containing Fuji II LC material was more successful in terms of retention in newly erupted permanent first molars when compared to other applied materials. Whereas the glass ionomer containing Fuji Triage material showed low retention rates, it was determined that the remineralization effect was higher than the other materials.
Benzer Tezler
- A hermeneutic approach to the English translation of Bilge Karasu's Göçmüş Kediler Bahçesi and Uzun Sürmüş Bir Günün Akşamı
Bilge Karasu'nun Göçmüş Kediler Bahçesi ve Uzun Sürmüş Bir Günün Akşamı eserlerinin İngilizce çevirileri üzerine yorumbilimsel bir inceleme
NACİYE TAŞDELEN
Yüksek Lisans
İngilizce
2014
Mütercim-TercümanlıkHacettepe Üniversitesiİngilizce Mütercim Tercümanlık Ana Bilim Dalı
PROF. DR. ASALET ERTEN
- Yeni Assur başkentlerinde tapınak inşa politikası
Temple building policy in the New Assur capitals
BİRTANE BAYLAN
- Alman yeni nesnellik (Neue Sachlichkeit) akımının çağdaş resme yansımaları ve leipzig okulu sanatçıları
Influence of The German new objectivity (Neue Sachlichkeit) on contemporary painting and the leipzig school painters
HAMDİ GÖKOVA
Sanatta Yeterlik
Türkçe
2015
Güzel SanatlarDokuz Eylül ÜniversitesiResim Ana Sanat Dalı
PROF. MÜMTAZ SAĞLAM
- Yeni muhafazakarlar, Irak savaşı ve İslamofobi
Neo-conservatives, Iraq war and Islamophobia
MUHAMMED ÇAĞRI GÜLER
Yüksek Lisans
Türkçe
2019
Siyasal BilimlerBaşkent ÜniversitesiSiyaset Bilimi ve Uluslararası İlişkiler Ana Bilim Dalı
PROF. DR. MENDERES ÇINAR
- Yeni Kafkasya mecmuasına göre Rusya`nın Azerbaycan politikası
Başlık çevirisi yok
CEM KARAKILIÇ
Yüksek Lisans
Türkçe
2005
TarihGazi ÜniversitesiTürkiye Cumhuriyeti Tarihi Ana Bilim Dalı
Y.DOÇ.DR. MEHMET ALİ ÇAKMAK