Farklı yüzey tasarımları ve titanyum içeriğine sahip dayanaklar ile implant üstü restorasyonlar arasındaki retansiyon kuvvet değerlerinin karşılaştırmalı olarak incelenmesi
Comparative study of alteration in retention force values of different titanium grades and abutment designs with implant-supported crowns
- Tez No: 665729
- Danışmanlar: DR. ÖĞR. ÜYESİ MELİH ÜLGEY
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Abutment, Retansiyon, İmplant, Oluk Tasarımı, Dental bonding, Dental destekler, Dental implantasyon, Dental materyaller, Dental protez-implant destekli, Dental restorasyon, Titanyum, Yüzey pürüzlülüğü, Abutment, Retention, Implant, Groove Design, Dental bonding, Dental abutments, Dental implantation, Dental materials, Dental prosthesis-implant supported, Dental restoration, Titanium, Surface roughness
- Yıl: 2021
- Dil: Türkçe
- Üniversite: Sivas Cumhuriyet Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Desimantasyon; protezlerin, dayanaklara olan tutuculuklarındaki kayıp nedeniyle meydana gelen, önemli bir klinik problemdir. Yapay dişin dayanağa olan tutuculuğu; seçilen siman tipine, dayanak geometrisine, dayanak yüzeyindeki retansiyon oluklarının geometrisine, dayanak yüzey pürüzlülük değerine göre farklılıklar gösterebilmektedir. Dayanak üzerinde bulunan retansiyon oluklarının tasarımı ve sayısı, yapay dişin tutuculuğunu primer olarak etkiler. Bu çalışmanın amacı, farklı grade tiplerine ve farklı retansiyon oluklarına sahip abutment dayanaklara, üretilen restorasyonun tutuculuğunun in vitro ortamda araştırılmasıdır. Çalışmamızda her birinden 32 örnek olacak şekilde, Grade-4, Grade-5, Grade-23 titanyumdan dayanak üretimi yapıldı. Her grup; retansiyon oluklarının tasarımlarındaki farklılıklara göre (yatay, dikey, çapraz ve S-formunda) 4 alt gruba ayrıldı. Dayanaklara uygun üst yapı üretimleri dijital iş akışı ile gerçekleştirildi ve üretilen üst yapılar çinko polikarboksilat simanla dayanaklara simante edildi. Çekme testi, dikey yönde 5 mm/dk hız ile gerçekleştirildi. Tüm veriler Newton cinsinden kaydedildi. Verilerin istatistiksel analizi iki yönlü ANOVA ve Tukey post hoc testi ile gerçekleştirildi. Titanyum grade türündeki değişimlerin, bağlantı dayanımında istatistiksel olarak anlamlı bir etki yaratmadığı (p>0.05), retansiyon oluğu tasarımındaki değişimlerin ise istatistiksel olarak anlamlı bir etki yarattığı bulundu (p<0.05) ve alt analizlere geçildi. Grade-4 titanyumdan üretilen dayanaklar incelendiğinde; yatay retansiyon oluğu grubu bağlantı dayanımı değeri, dikey, çapraz ve S-formu gruplarının bağlantı dayanımı değerlerine göre anlamlı derecede yüksek bulundu (p<0.05). Grade-5 titanyumdan üretilen dayanaklar incelendiğinde; yatay retansiyon oluğu grubu ile dikey retansiyon oluğu grubunun bağlantı dayanımı değerleri arasında istatistiksel anlamlılık saptanmadı (p>0.05). Ancak hem yatay hem de dikey retansiyon oluğu gruplarının bağlantı dayanımları, çapraz ve S-formu retansiyon oluğu gruplarının bağlantı dayanımı değerlerine göre istatistiksel olarak anlamlı derecede yüksek bulundu (p<0.05). Grade-23 titanyumdan üretilen dayanaklar incelendiğinde, yatay retansiyon oluğu grubu ile dikey retansiyon oluğu grubunun bağlantı dayanımı değerleri arasında istatistiksel anlamlılık saptanmadı (p>0.05) ancak çapraz ve S-formu retansiyon oluğu gruplarının bağlantı dayanımı değerlerine göre istatistiksel olarak anlamlı derecede yüksek bulundu (p<0.05). Sonuç olarak; aynı retansiyon oluğu tasarımında farklı grade tipi kullanımı, tutuculuk değerini değiştirmedi. Grade-4 ve grade-23 titanyum dayanaklarda yatay, grade-5 titanyum dayanakta yatay veya dikey retansiyon oluğu tasarımı tercih edilmelidir. Çapraz veya S-formu dayanak tasarımı, tutuculuğa olumlu katkı sağlamamaktadır.
Özet (Çeviri)
The problem of desimentation, which is seen due to the loss of adhesion of prostheses to abutments, is an important clinical problem. The adhesion of the artificial tooth to the abutment can vary depending on many factors: The selected cement type, abutment geometry, geometry of retention grooves on the abutment surface, abutment surface roughness value. The design and number of retention grooves on the abutment primarily affect the retention of the artificial tooth. The aim of this study is to investigate the retention of the produced restoration on abutment abutments with different grade types and different retention grooves in vitro. In our study, Grade 4, Grade 5, Grade 23 titanium abutments, with 32 samples from each, were produced. Each group is divided into 4 subgroups according to the differences in the retention grooves design (horizontal, vertical, cross, and S form). The abutments were scanned with a laboratory scanner and transferred to the system, superstructures suitable for abutments were designed and produced by the laser sintering method. The restorations were cemented to the abutments with zinc polycarboxylate cement. All samples were placed in the tensile test device. The test was carried out by applying a pulling speed of 5 mm/min in the vertical direction. All data are recorded in Newtons. Data were carried out with two-way ANOVA and Tukey post hoc test. It was found that changes in titanium grade type did not have a statistically significant effect on bond strength (p>0.05). It was found that the changes in retention groove design had a statistically significant effect (p<0.05) and sub-analyzes were made. When the abutments made of Grade 4 titanium were examined; the bond strength value of the horizontal retention groove group was significantly higher than the bond strength values of the vertical, cross and S form groups (p<0.05). When the abutments made of Grade 5 titanium were examined; there was no statistically significant difference between the bond strength values of the horizontal retention groove group and the vertical retention groove group (p>0.05). But the connection strength of both horizontal and vertical retention groove groups was statistically significantly higher compared to the connection strength values of cross and S form retention groove groups (p<0.05). When the abutments made of Grade 23 titanium were examined, no statistical significance was found between the bond strength values of the horizontal retention groove group and the vertical retention groove group (p>0.05), but it was found to be statistically significantly higher than the bond strength values of the cross and S form retention groove groups (p<0.05). As a result; using different grade type in the same retention groove design does not change the retention value. Horizontal retention groove design should be preferred for grade 4 and grade 23 titanium abutments, horizontal or vertical for grade 5 titanium abutments. Cross or S form abutment design does not contribute positively to adhesion.
Benzer Tezler
- Hibrit kompozitlerde farklı metal bağlantılarının yapıştırma özelliklerinin belirlenmesi
Determination of adhesive bonding properties of different metals in hybrid composites
HANDE OSMANOĞLU
Yüksek Lisans
Türkçe
2018
Makine Mühendisliğiİstanbul Teknik ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
PROF. DR. MUSTAFA BAKKAL
- Controlled drug released in a microfludic system using mesoporous silica nanoparticles
Mikroakışkan sistem içerisinde gözenekli silika yardımıyla kontrollü ilaç salımı
İPEK İREM AYKIN
Yüksek Lisans
İngilizce
2019
Mühendislik Bilimleriİstanbul Teknik ÜniversitesiNanobilim ve Nanomühendislik Ana Bilim Dalı
PROF. DR. HÜSEYİN KIZIL
- Havacılık endüstrisinde kullanılan malzemelerin farklı özelliklerdeki kesici takımlar ile işlenmesi ve performanslarının incelenmesi
Machining of materials used in aviation industry with cutting tools of different properties and investigation of their performance
ANIL YILMAZ
Yüksek Lisans
Türkçe
2022
Makine MühendisliğiEskişehir Osmangazi ÜniversitesiHavacılık Bilimi ve Teknolojileri Ana Bilim Dalı
DR. ÖĞR. ÜYESİ ZERRİN SERT
- Dijital ölçü aşamasında kullanılan titanyum ve peek tarama gövde materyallerinin yer değiştirmeye bağlı hassasiyetinin değerlendirilmesi
Evaluation of displacement precision of titanium and peek scan body materials used in digital impression
EMRE DİKER
Diş Hekimliği Uzmanlık
Türkçe
2021
Diş HekimliğiAnkara ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. SEDAT HAKAN TERZİOĞLU
- Ti6Al4V titanyum alaşımlarının minimum miktarda yağlama (MMY) tekniği ile tornalanmasında kullanılan bitkisel yağlara hBN nanoparçacık katkısının işleme performansına etkisi
The effect of hbn nanoparticle addition on processing performance to vegetable oils used in turning ti6al4v titanium alloy's with minimum quantity lubrication (mql) technique
MUHAMMET ÇELİK
Yüksek Lisans
Türkçe
2022
Makine MühendisliğiZonguldak Bülent Ecevit ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
DR. ÖĞR. ÜYESİ AYŞEGÜL ÇAKIR ŞENCAN