Ortodontik model analizinde kullanılan pont, schwartz ve andrew element III model analizlerinin sonuçlarının karşılaştırılması
Comparison of results of pont, schwartz and andrew ele-ment III model analysis used in orthodontic model analysis
- Tez No: 664758
- Danışmanlar: DR. ÖĞR. ÜYESİ SEDEN AKAN BAYHAN
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Alveolar kenar artırılması, Maksilla, Maksilla hastalıkları, Model geçerliliği, Ortodonti, Çene, Alveolar ridge augmentation, Maxilla, Maxillary diseases, Model validation, Orthodontics, Jaw
- Yıl: 2021
- Dil: Türkçe
- Üniversite: Altınbaş Üniversitesi
- Enstitü: Lisansüstü Eğitim Enstitüsü
- Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
- Bilim Dalı: Ortodonti Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
AMAÇ: Bu çalışmanın amacı, üst çenenin transversal darlık miktarını ölçen model analiz yöntemlerinden Pont, Schwartz ve Andrew Element III model analizlerinin sonuçlarının karşılaştırılmasıdır. GEREÇ VE YÖNTEM: Altınbaş Üniversitesi Diş Hekimliği Fakültesi Ortodonti Anabilim Dalı'na ortodontik tedavi amacıyla başvuran maksiller darlığa sahip 60 hastanın ortodontik modelleri üzerinde model analiz yöntemleri uygulanmıştır. Pont, Andrew ve Schwartz formülleri ile, 60 ortodontik çalışma modeli üzerinde premolarlar 'Ka' ve molarlar 'Ba' arası transversal genişlik miktarı hesaplanmış ve olması gereken ideal transversal genişlik miktarından çıkarılarak darlık miktarları ölçülmüştür. Schwartz model analizi yapılırken hastaların yüz indisi ölçüme dahil edilmiştir. İstatiksel analiz amacıyla, Kolmogorov-Smirnov, ANOVA ve Kruskal Wallis testleri kullanılmıştır. BULGULAR: Pont 'Ka'-'Ka' ile Schwarz 'Ka'-'Ka' ölçümleri arasındaki ilişki istatistiksel olarak anlamlı doğrusal, pozitif ve çok güçlü (r= 0,928, p<0,05), Pont 'Ba'-'Ba' ile Schwarz 'Ba'-'Ba' ölçümleri arasındaki ilişki istatistiksel olarak anlamlı doğrusal pozitif ve güçlüdür (r=0,767, p<0,05). ). Pont 'Ba'-'Ba' ile Andrew 'Ba'-'Ba' ölçümleri arasındaki ilişki ile Schwarz 'Ba'-'Ba' ile Andrew 'Ba'-'Ba' ölçümleri arasındaki ilişki istatistiksel olarak anlamlı doğrusal pozitif ve zayıf bulunmuştur (r=0,491, p<0,05) (r=0,439, p<0,05). SONUÇ: Pont ve Schwartz model analizlerinin sonuçları arasındaki ilişki güçlü-anlamlıyken, Andrew model analizinin sonuçlarının Pont ve Schwartz model analizlerinin sonuçlarıyla arasındaki ilişki zayıftır.
Özet (Çeviri)
OBJECTIVE: The aim of this study was to compare the results of Pont, Schwartz and Andrew Element III model analyses, which are among the model analysis methods that measure the amount of transversal deficiency of the upper jaw. MATERIAL AND METHOD: Model analysis methods were applied on the orthodontic models of 60 patients who applied to Altınbaş University Faculty of Dentistry Department of Orthodontics for orthodontic treatment. Using Pont, Andrew and Schwartz formulas, the amount of transversal width between premolars 'Ka' and molar 'Ba' was calculated on 60 orthodontic models and the amount of stenosis was measured by subtracting the ideal transversal width amount. While the Schwartz model analysis was performed, the face index of the patients was included in the measurement. Kolmogorov-Smirnov, ANOVA and Kruskal Wallis tests were used for statistical analysis. RESULTS: The relationship between Pont 'Ka' - 'Ka' and Schwarz 'Ka' - 'Ka' measurements was statistically significant, linear, positive and very strong (r = 0.928, p <0.05), the relationship between Pont 'Ba' - 'Ba' and Schwarz 'Ba' - 'Ba' measurements was statistically significant, linear positive and strong (r = 0.767, p <0.05). The relationship between Pont 'Ba' - 'Ba' and Andrew 'Ba' - 'Ba' measurements and the relationship between Schwarz 'Ba' - 'Ba' and Andrew 'Ba' - 'Ba' measurements were found to be statistically significant, linearly positive and weak (r = 0.491, p <0.05) (r = 0.439, p <0.05). CONCLUSION: While the relationship between the results of Pont and Schwartz model analysis was strong-significant, the relationships between the results of the Andrew model analysis and the results of the Pont and Schwartz model analysis were weak.
Benzer Tezler
- Sayısal ortodontik model analizinde kullanılan farklı yazılımların tekrarlanabilirlik, güvenilirlik ve hassasiyet açılarından karşılaştırılması
Comparison of accuracy, reliability, and reproducibility of 3 different digital model softwares
AYDAN COŞKUN ATEŞ
- Farklı üst çene genişletme aygıtlarının tedavi etkinliklerinin ve maksilla ve mandibula üzerine olan etkilerinin karşılaştırmalı olarak incelenmesi
Evaluation of treatment efficiency and effects with different rapid maxillary expansion devices on maxilla and mandible
SELİN CANAN
Doktora
Türkçe
2015
Diş HekimliğiSüleyman Demirel ÜniversitesiOrtodonti Ana Bilim Dalı
YRD. DOÇ. NESLİHAN EBRU ŞENIŞIK
- Bracket position differences in digital indirect bonding vs manual indirect bonding technique
Dijital ve manuel indirekt braketleme tekniklerinde braket pozisyonlandırma farklıllıklarının değerlendirilmesi
FRANTZESKA KARKAZI
Yüksek Lisans
İngilizce
2022
Diş HekimliğiMarmara ÜniversitesiOrtodonti Ana Bilim Dalı
YRD. DOÇ. ECE ABUHAN
- Kemik destekli cerrahi hızlı maksiller genişletme ile diş destekli ardışık hızlı aktivasyon-deaktivasyon yönteminin mid-fasiyal bölge üzerindeki etkisinin sonlu elemanlar analizi ile karşılaştırılması
Comparison of the effect of bone-borne surgical rapid maxillary expansion and tooth-borne sequential rapid activation-deactivation on the mid-facial region with finite element analysis
ECEM EFE
- Jones jig ile distal jet apareylerinin iskeletsel ve dentoalveoler etkilerinin sefalometrik olarak karşılaştırılması
Jones jig versus distal jet appliance: cephalometrically skeletal and dentalveolar comparison
OSAMA QASRAWI