Bakterilerin polimerik yüzeylerle etkileşimi
Interaction between bacteria and polymeric surface
- Tez No: 66034
- Danışmanlar: PROF. DR. ERHAN PİŞKİN
- Tez Türü: Doktora
- Konular: Biyomühendislik, Bioengineering
- Anahtar Kelimeler: Bakteriler, Biyomalzemeler, Polimerler, Bacteria, Biomaterials, Polymers
- Yıl: 1997
- Dil: Türkçe
- Üniversite: Hacettepe Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Biyomühendislik Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Abstract ABSTRACT The aim of this study is to investigate interactions of bacteria with biomaterials, and to decrease the bacterial adhesion by modification of biomatenal surface with plasma polymerization. Six gram positive and four gram negative bacteria strains were isolated from clinical samples, and identified by several techniques. Hydrophobicities of these bacteria were defined by using contact angles and the percentage of bacteria passed to organic phase (i.e., /j-xylene). Zeta potentials and surface charges of the bacteria were determined as electrostatic properties. Several biodegradable or nondegradable mono or multifiament sutures (i.e., Vicryl, Dexon, Cromic catgut, PDS and PP), a polyvinylchloride (PVC) catheter and a silicone (Si) balloon catheter were evaluated as biomaterials. Surfaces of these biomaterials were modified by plasma polymerization in which dimethylaminoethyl methacrylate (DMAEMA) and acrylic acid (AAc) were used as the active monomers. Plasma modifications were performed for different plasma exposure times (5, 10 and 15 min) and discharge powers (5 and 10 watt). Contact angles of both original and plasma modified biomaterial were obtained by a captive bubble technique. The contact angles of gram positive bacteria were in the range of 48-69°, which means that they are moderately hydrophobic (except the CNS-2 strain which is relatively hydrophilic). While the contact angles of gram negative bacteria were in the range of 43.5-55°, which means that they are moderately hydrophilic. Hydrophobicities of both groups of bacteria defined with the percentage of bacteria passed to /»-xylene phase were obtained in parallel to those defined by contact angles. All bacteria accept CNS-2 and CPS-1 exhibited negative surface charge. Zeta potentials of the gram positive and gram negative bacteria were found in a wide range from +1 8.60 to -650 mV. Only two of the strains, i.e., CNS-2 and CPS-1, exhibited positive zeta potential values which were +18.6 and + 17.5, respectively. For bacterial adhesion studies the optimal concentration of bacteria was obtained as lxl09(cfu/cm2). Bacterial adhesion was found as a function of incubation time. The strains adhesion of some bacteria decreased with respect to time, while for some others increased.Abstract Bacterial adhesion which obtained in dynamic incubation media was higher than those observed in static experimental set up. The maximum bacterial adhesion was observed for Vicryl sutures. In the plasma modification of these sutures, in which DMAEMA and AAc plasma were used, the optimal (corresponding the minimum bacterial adhesion) plasma exposure time and discharge power were obtained at 5 min and 10 watt, respectively. Very similar adhesion behaviours were observed for all biomaterials tested in this study (i.e., Vicryl sutures, PVC catheters and Silicone balloon catheter). The highest gram positive bacterial adhesions were observed for Silicone balloon catheter, while much lower values were found for Vicryl sutures. Among the gram positive bacteria used in this study the highest adhesions were observed for the CNS-1 and S.yug-1 strains. In most of the cases (but not all) there were correlations between the extend of adhesion and surface properties of both the bacteria and the biomaterial. Hydrophobic gram positive bacteria have adhered more to the hydrophobic biomaterial surfaces. While, just opposite, more hydrophilic gram negative bacteria have been found to adhere to more hydrophilic biomaterial surfaces. The main result in respect to the main aim of this study it was shown that in most of the cases, especially for the CNS-1, CNS-2, CPS-1, E.coli-1, E.coli-2 and P.aeru-1 strains plasma modification significantly improved the antibacterial character (means less bacterial adhesion) of all biomaterials tested. The AAc plasma was more succesful than the DMAEMA plasma in this respect.
Özet (Çeviri)
Abstract ABSTRACT The aim of this study is to investigate interactions of bacteria with biomaterials, and to decrease the bacterial adhesion by modification of biomatenal surface with plasma polymerization. Six gram positive and four gram negative bacteria strains were isolated from clinical samples, and identified by several techniques. Hydrophobicities of these bacteria were defined by using contact angles and the percentage of bacteria passed to organic phase (i.e., /j-xylene). Zeta potentials and surface charges of the bacteria were determined as electrostatic properties. Several biodegradable or nondegradable mono or multifiament sutures (i.e., Vicryl, Dexon, Cromic catgut, PDS and PP), a polyvinylchloride (PVC) catheter and a silicone (Si) balloon catheter were evaluated as biomaterials. Surfaces of these biomaterials were modified by plasma polymerization in which dimethylaminoethyl methacrylate (DMAEMA) and acrylic acid (AAc) were used as the active monomers. Plasma modifications were performed for different plasma exposure times (5, 10 and 15 min) and discharge powers (5 and 10 watt). Contact angles of both original and plasma modified biomaterial were obtained by a captive bubble technique. The contact angles of gram positive bacteria were in the range of 48-69°, which means that they are moderately hydrophobic (except the CNS-2 strain which is relatively hydrophilic). While the contact angles of gram negative bacteria were in the range of 43.5-55°, which means that they are moderately hydrophilic. Hydrophobicities of both groups of bacteria defined with the percentage of bacteria passed to /»-xylene phase were obtained in parallel to those defined by contact angles. All bacteria accept CNS-2 and CPS-1 exhibited negative surface charge. Zeta potentials of the gram positive and gram negative bacteria were found in a wide range from +1 8.60 to -650 mV. Only two of the strains, i.e., CNS-2 and CPS-1, exhibited positive zeta potential values which were +18.6 and + 17.5, respectively. For bacterial adhesion studies the optimal concentration of bacteria was obtained as lxl09(cfu/cm2). Bacterial adhesion was found as a function of incubation time. The strains adhesion of some bacteria decreased with respect to time, while for some others increased.Abstract Bacterial adhesion which obtained in dynamic incubation media was higher than those observed in static experimental set up. The maximum bacterial adhesion was observed for Vicryl sutures. In the plasma modification of these sutures, in which DMAEMA and AAc plasma were used, the optimal (corresponding the minimum bacterial adhesion) plasma exposure time and discharge power were obtained at 5 min and 10 watt, respectively. Very similar adhesion behaviours were observed for all biomaterials tested in this study (i.e., Vicryl sutures, PVC catheters and Silicone balloon catheter). The highest gram positive bacterial adhesions were observed for Silicone balloon catheter, while much lower values were found for Vicryl sutures. Among the gram positive bacteria used in this study the highest adhesions were observed for the CNS-1 and S.yug-1 strains. In most of the cases (but not all) there were correlations between the extend of adhesion and surface properties of both the bacteria and the biomaterial. Hydrophobic gram positive bacteria have adhered more to the hydrophobic biomaterial surfaces. While, just opposite, more hydrophilic gram negative bacteria have been found to adhere to more hydrophilic biomaterial surfaces. The main result in respect to the main aim of this study it was shown that in most of the cases, especially for the CNS-1, CNS-2, CPS-1, E.coli-1, E.coli-2 and P.aeru-1 strains plasma modification significantly improved the antibacterial character (means less bacterial adhesion) of all biomaterials tested. The AAc plasma was more succesful than the DMAEMA plasma in this respect.
Benzer Tezler
- Doymamış bakteriyel polyester üzerine metil metakrilatın graft kopolimerizasyonu
Graft copolymerizastion of metylmethacrylate onto bacterial polyester containing unsaturated side chains
SONGÜN İLTER
- Synthesis of polyhydroxybutyrate and its copolymers by alcaligenes latus and alcaligenes eutrophus
Polihidroksibütirat ve kopolimerlerinin alcaligenes latus ve alcaligenes eutrophus ile sentezlenmesi
ZEYNEP GÜMÜŞYAZICI
Yüksek Lisans
İngilizce
1999
BiyoteknolojiOrta Doğu Teknik ÜniversitesiBiyoteknoloji Ana Bilim Dalı
PROF. DR. GÜRDAL ALAEDDİNOĞLU
- Bazı böcek patojeni bakterilerin çeşitli immobilizasyon teknikleriyle özelliklerinin modifikasyonu
Modification of some insect pathogene bacteria's characteristics by several immobilization techniques
Y. MURAT ELÇİN
- Isolation of monobromoacetate and dichlaroacetate degrading bacteria from polluten seawater and analysis of haloacid de halogenaze geofypes by using polymerase choun reaction (PCR)
Monobromoasetat ve dikloroasetat parçalayan bakterilerin kirlenmiş deniz suyundan izolasyonu ve haloasit dehalogenaz genotiplerinin polimeraz zincir reaksiyonu ile analizi
BANU FIRAT
Yüksek Lisans
İngilizce
2000
BiyolojiOrta Doğu Teknik ÜniversitesiBiyoloji Ana Bilim Dalı
PROF. DR. SEMRA KOCABIYIK
- Çeşitli bakterilerde ERM (eritromisin rezistans metilazı) geninin polimeraz zincir reaksiyonu (PCR) yöntemi ile saptanması
Detection of ERM (erythromycin resistance methylase) gene by polymerase chain reaction
U. BERKAND KANRA