Farklı dayanak materyallerinin hemen yükleme sonrası implant çevresi dokulara etkisinin karşılaştırılması: in vivo çalışma
Compari̇son of the effects of di̇fferent temporary abutment materi̇als on peri̇-i̇mplant ti̇ssues after i̇mmedi̇ate loadi̇ng: in vivo study
- Tez No: 658595
- Danışmanlar: PROF. DR. MUSTAFA ZORTUK
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Hemen Yükleme, PEEK, Titanyum, Dayanak, Dental implantasyon, Dental implantlar, Dental materyaller, Dental restorasyon, Takma diş tabanları, İn vivo, Immediate Loading, PEEK, Titanium, Abutment, Dental implantation, Dental implants, Dental materials, Dental restoration, Denture bases, In vivo
- Yıl: 2019
- Dil: Türkçe
- Üniversite: Hatay Mustafa Kemal Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Farklı Dayanak Materyallerinin Hemen Yükleme Sonrası İmplant Çevresi Dokulara Etkisinin Karşılaştırılması: İn Vivo Çalışma Giriş ve Amaç:Titanyum; mükemmel üstün fiziksel ve mekanik özellikleri göz önüne alınarak, dayanak materyalleri açısından altın standart olarak kabul edilmektedir. Ancak günümüzde titanyum, estetiğin ön planda olduğu bölgelerde, sahip olduğu metalik rengin implant çevresi mukozada oluşturduğu grimsi yansıma nedeniyle estetik bakımdan yetersiz kalmaktadır. Bu çalışmanın amacı, hemen yükleme protokolüyle titanyum dayanaklar üzerine hazırlanan geçici restorasyonlara alternatif olarak, PEEK dayanak kullanılarak hazırlanan geçici restorasyonların, implant çevresi kemikte meydana gelen kemik kaybına ve implant çevresindeki dokulara etkisinin in vivo olarak incelenmesidir. Gereç ve Yöntem: Bu çalışma, 21 hastaya (13 kadın, 8 erkek) uygulanan 32 implant üzerine titanyum ve PEEK dayanaklar kullanarak (14 titanyum ve 18 PEEK) hazırlanan geçici restorasyonlar ile gerçekleştirildi. İmplantların cerrahi olarak yerleştirilmesinden önce, hastanın ağız içi, ağız dışı ve radyografik muayeneleri yapıldı. Hastalar titanyum dayanak grubu (Grup Ti) ve PEEK dayanak grubu (Grup PEEK) olacak şekilde iki gruba ayrıldı. Her iki grupta da tüm implantlar, üretici firmanın önerileri doğrultusunda, cerrahi olarak kemiğe yerleştirildi. Cerrahi işlem bitiminde implantların ölçüsü kapalı kaşık ölçü tekniği ile polivinilsiloksan ölçü maddesi kullanılarak implant seviyesinde alındı. Model üzerinde oluşturulması düşünülen dişeti kazınarak gruplara göre uygun titanyum veya PEEK dayanaklar analoğun üzerine vidalandı ve geçici restorasyon hazırlanarak hastaya uygulandı. İmplant çevresi kemik seviyesi, ISQ değerleri, sondalama derinliği, kanama indeksi, gingival indeks, plak indeksi ve keratinize dişeti yüksekliği miktarları; operasyon günü, 1. ay sonunda ve 3. ay sonunda olacak şekilde ölçülerek kaydedildi. Çalışmamızda elde edilen verilerin normalitesi Shapiro-Wilks testi kullanılarak p=0,05 anlamlılık düzeyinde değerlendirildi. Ölçülen kemik kaybı ve ISQ değerleri ve bu değerler üzerine faktör etkileşimleri tekrarlanan ölçümler ANOVA testi ve Bonferroni düzelmesi kullanılarak Post-Hoc Tukey HSD testi ile p=0,05 anlamlılık düzeyinde değerlendirildi. Hastalardan elde edilen niceliksel verilerin birbirleriyle olan ilişkileri ise; p=0,05 anlamlılık düzeyinde Pearson korelasyon analizi kullanılarak değerlendirildi. Bulgular: Yapılan istatistiksel değerlendirmeler doğrultusunda, dayanak çeşidinin ISQ değerleri üzerine anlamlı bir etkisinin olmadığı (p>0,05), dayanak çeşidinden bağımsız şekilde implant çapının ISQ değerleri üzerinde etkili olduğu (p<0,05) görüldü. PEEK dayanak kullanılan grupta titanyum dayanak grubuna göre daha az marjinal kemik kaybı gözlendiği (p<0,05). Periodontal skorlar bakımından iki grupta da benzer sonuçlar elde edildiği (p>0,05) görüldü. Sonuçlar: Bu çalışmanın limitasyonları dahilinde; PEEK dayanak kullanılan hasta grubunda daha az kemik kaybı olduğu (p<0,05), PEEK ve titanyum dayanaklar arasında ISQ değerleri ve klinik değerlendirmeler bakımından farklılık gözlenmediği (p>0,05) implant boyunun ISQ değerleri üzerine anlamlı bir etkisi olmadığı (p>0,05) implant çapının ISQ değerleri üzerine anlamlı bir etkisi olduğu görüldü. (p<0,05).Uygun dayanak materyali seçimi, implantların uzun dönem başarısı üzerine etkili olduğu gözlendi.
Özet (Çeviri)
ABSTRACT Comparison of the Effects of Different Temporary Abutment Materials on Peri-implant Tissues After Immediate Loading: In Vivo Study Introduction and Aim: Titanium is considered to be the gold standard among the abutment materials, given its excellent superior physical and mechanical properties.However, it is insufficient in aesthetic areas due to the grayish reflection caused by metallic color around the implant.The aim of this study was to evaluate the effect of PEEK abutments, an alternative to titanium abutments, with acrilic temporary restorations using immediate loading protocol on the marginal bone loss and periimplant tissues. Materials and Methods:This study was performed with temporary restorations using 32 titanium and PEEK abutments (14 titantum and 18 PEEK) on 32 implants performed on 21 patients (13 females, 8 males). Before surgical placement of the implants, intraoral and radiographic examinations were performed. The patients were divided into two groups as titanium abutment group (Grup Ti) and PEEK abutment group (Grup PEEK).In both groups, all implants were placed according to the manufacturer's recommendations. After surgery, impressions were taken using polyvinyl siloxane impression material and closed spoon impression technique.The gingiva which is thought to be formed on the model was scraped and screwed onto the appropriate titanium or PEEK abutment analogue according to the groups and temporary restoration was prepared and applied on the implant.The data were evaluated using repeated measures ANOVA and Post-Hoc Tukey HSD test with Bonferroni correction(a:0.05) at a significance level of p=0.05.The relationships between the quantitative data were evaluated using Pearson correlation analysis at p=0.05 significance level. Results:.The results of the statistical analysis show that abutment type have no significant effect of the abutment type on ISQ values (p> 0.05), but the diameter of implant significantly affected ISQ values independently from abutment type (p <0.05). Less marginal bone loss was observed in the PEEK abutment group compared to the titanium abutment group (p <005), and similar results were obtained in both groups in terms of periodontal scores (p> 0.05). Conclusions:Within the limitations of this study; there was less bone loss in the PEEK abutment group (p <0.05). There was no difference between PEEK and titanium abutments in terms of ISQ values and clinical evaluations (p> 0.05). Implant length did not have a significant effect on ISQ values (p> 0.05), and implant diameter had a significant effect on ISQ values. (P <0.05). Suitable abutment material selection is effective on the long-term success of implants.
Benzer Tezler
- Mandibular iki implant destekli overdenturelarda kantilever peek bar tasarımının implantlar etrafındaki strese etkisi
The effect of cantilever peek bar design on stress around implants in mandibular two implant supported overdenture prostheses
NAZLICAN GÜNEŞ
Doktora
Türkçe
2026
Diş HekimliğiEge ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. AYŞE GÖZDE TÜRK
- Performance tests of hybrid membrane bioreactor (IFAS MBR) system in different sludge and hydraulic retention time
Hibrit membran biyoreaktor (IFAS MBR) sisteminin farklı çamur yaşı (SRT) ve hidrolik bekletme (HRT) sürelerinde performans testlerinin yapılması
ELİF CEREN ESEN
Yüksek Lisans
İngilizce
2024
Çevre Mühendisliğiİstanbul Teknik ÜniversitesiÇevre Mühendisliği Ana Bilim Dalı
DR. ÖĞR. ÜYESİ TÜRKER TÜRKEN
- Farklı materyallerden üretilen implant dayanaklarının fibroblast hücreleri üzerine sitotoksik etkilerinin araştırılması
Investigation of cytotoxic effects of implant abutments manufactured from different materials on fibroblast cells
ELİF AYGÜN ÇİMENTEPE
Doktora
Türkçe
2022
Diş HekimliğiEge ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. EBRU KARABECE ÇAL
- Farklı CAD/CAM adeziv restorasyon uygulamalarında dinamik-yaşlandırma işleminin bağlanma dayanıklılığına etkisinin incelenmesi
Effect of dynamic-aging on bond strength of different types of CAD/CAM adhesive restorations
İREM BÜYÜKATEŞ
Doktora
Türkçe
2025
Diş HekimliğiAnkara ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. SADULLAH ÜÇTAŞLI
- Farklı jig kalınlıklarının ve materyallerinin dentoalveolar yapılara etkisinin sonlu elemanlar analizi ile değerlendirilmesi
Evaluation of the effect of different jig thicknesses and materials on dentoal veolar structures using finite element analysis
TUĞBA ISLAK
Diş Hekimliği Uzmanlık
Türkçe
2025
Diş HekimliğiBolu Abant İzzet Baysal ÜniversitesiOrtodonti Ana Bilim Dalı
DR. ÖĞR. ÜYESİ MUSA BULUT
DOÇ. DR. YASİN HEZENCİ