Kan varlığında veya yokluğunda kök ucuna yerleştirilen farklı endodontik tamir materyallerinin dentine bağlanma dayanımlarının değerlendirilmesi
Evaluation of the bond strengths to dentine of root-end placed different endodontic repair materials in the presence / absence of blood contamination
- Tez No: 656917
- Danışmanlar: DOÇ. DR. HÜDA MELİKE BAYRAM
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Dental bonding, Dental materyaller, Kan, Kök kanal dolgu materyalleri, Kök kanal tedavisi, Kök kanalını tıkama, Mikrobiyal kirlilik, Mineral trioksit agregat, Dental bonding, Dental materials, Blood, Root canal filling materials, Root canal therapy, Root canal obturation, Microbial contamination, Mineral trioxide aggregate
- Yıl: 2021
- Dil: Türkçe
- Üniversite: Tokat Gaziosmanpaşa Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Endodonti Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Bu in vitro çalışmanın amacı; kan kontaminasyonu varlığında veya yokluğunda kök ucuna yerleştirilen MTA Repair HP, RetroMTA ve MTA Flow'un dentine bağlanma dayanımlarının değerlendirilmesidir. Materyal ve Metod: Bu çalışmada tek köklü 90 adet maksiler santral diş kullanıldı. Dişlere endodontik tedavi uygulandıktan sonra kök uçları 3 mm rezeke edildi ve kök ucu kaviteleri hazırlandı. Öncelikle örnekler, kavitelerin kanla kontaminasyonuna göre (+/-) 2 gruba ayrıldı. Daha sonra kök ucu dolgu malzemelerine göre (MTA Repair HP, RetroMTA, MTA Flow) üç alt gruba ayrıldı (n=15) ve bu malzemeler üreticinin talimatları doğrultusunda karıştırılarak kaviteye yerleştirildi. Örnekler 21 gün boyunca 37°C'de %100 nemli ortamda bekletildikten sonra her bir dişin kök ucundan 1 adet olmak üzere 1.0±0.1 mm'lik dilimler elde edildi, üniversal test cihazıyla push-out bağlanma dayanımı testi yapıldı. Başarısızlık tipini değerlendirmek için her dilim stereomikroskop altında incelendi. Veriler, tek yönlü varyans analizi ve Bağımsız Örneklem T Testi kullanılarak analiz edildi. Bulgular: Dentine bağlanma dayanımı, kan kontaminasyonunun varlığından önemli ölçüde olumsuz yönde etkilendi (p<0.05). En yüksek ort. bağlanma dayanımı değeri MTA Flow (-) grubunda, en düşük ort. bağlanma dayanımı değeri ise MTA Repair HP (+) grubunda gözlendi. Hem kanla kontamine olan grupta hem de kanla kontamine olmayan grupta MTA Repair HP en düşük bağlanma dayanımını gösterirken MTA Flow ve RetroMTA arasında anlamlı farklılık bulunamadı. Sonuç: Sonuç olarak kan kontaminasyonunun dentine bağlanma dayanımını azalttığı, materyaller arasında en yüksek bağlanma dayanımını MTA Flow'un, en düşük bağlanma dayanımını MTA Repair HP'nin gösterdiği bulunmuştur.
Özet (Çeviri)
Objective: The aim of this in vitro study is evaluation of bond strength to dentin of root end placed MTA Repair HP, RetroMTA and MTA Flow in the presence or absence of blood contamination. Materials and Methods: In this study, ninety single-rooted maxillary central teeth were used. After endodontic treatment was applied to the teeth, the root end were resected 3 mm and retrograd cavities were prepared. First, samples were divided into (+/-) 2 groups according to the contamination with blood of the cavities. Later, samples was divided into three subgroups (n=15) according to the root end filling materials (MTA Repair HP, RetroMTA, MTA Flow) and these materials were prepared and applied to the cavity according to the manufacturer's instructions. After the samples were kept at 37°C in 100% humid environment for 21 days, 1.0±0.1 mm slices were obtained from the root end of each tooth, and they were subjected to the push-out bond strength test with the universal test device. Each slice was examined under a stereomicroscope to evaluate the failure mode. The data were analyzed using one‑way analysis of variance and Independent Sample T Test. Results: Bond strength to dentin was significantly negatively affected by the presence of blood contamination (p <0.05). The highest average bond strength value was observed in the MTA Flow (-) group and the lowest average bond strenght value was observed in the MTA Repair HP (+) group. No significant difference was found between MTA Flow and RetroMTA while MTA Repair HP showed the lowest bond strength in both the blood contaminated group and the non-blood contaminated group. Conclusion: As a result, it has been found that blood contamination reduces the bond strength to dentin, MTA Flow shows the highest bond strength and MTA Repair HP shows the lowest bond strength among the materials.
Benzer Tezler
- Smear tabakası"'nın varlığında ve yokluğunda doldurulan kök kanallarında apikal sızıntının incelenmesi
Başlık çevirisi yok
IŞIL KARAGÖZ KÜÇÜKAY
Doktora
Türkçe
1990
Diş Hekimliğiİstanbul ÜniversitesiDiş Hastalıkları ve Tedavisi Ana Bilim Dalı
PROF.DR. GÜNDÜZ BAYIRLI
- Akraba dışı hematopoetik kök hücre nakli yapılan hastaların uzun dönem takibi ve klinik seyir
Long term follow-up and clinical outcomes of unrelated hematopoetic stem cell transplantation
ELİF AKSOY
Tıpta Uzmanlık
Türkçe
2020
Hematolojiİstanbul Üniversitesiİç Hastalıkları Ana Bilim Dalı
DOÇ. İPEK YÖNAL HİNDİLERDEN
- Investigation of the effect of ATP13A2 (PARK9) frameshift mutation on the protein function
ATP13A2 (PARK9) çerçeve kayması mutasyonunun protein fonksiyonuna etkisinin incelenmesi
KORAY KIRIMTAY
Doktora
İngilizce
2021
Genetikİstanbul Teknik ÜniversitesiMoleküler Biyoloji-Genetik ve Biyoteknoloji Ana Bilim Dalı (disiplinlerarası)
PROF. DR. ARZU KARABAY KORKMAZ
- Glial tümörlerde kan ve tümör mikroçevresindeki innate lenfoid hücrelerin (ılc) karakterize edilmesi
Characterization of innate lymphoid cells (ilc) in the blood and tumor microenvironment in glial tumors
ŞERİFE ERDEM