CAD/CAM sistemleri kullanılarak üretilen üç üyeli implant destekli sabit bölümlü protez altyapılarının marjinal ve internal uyumlarının karşılaştırılması
Comparison of marginal and internal adaptation in the frameworks of three-unit implant supported fixed partial denture produced by using CAD/CAM systems
- Tez No: 646006
- Danışmanlar: DOÇ. DR. SABİT MELİH ATEŞ
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: CAD/CAM, Dental implant, İnternal uyum, Marjinal aralık, Sabit bölümlü protezler, Dental implantasyon, Dental implantlar, Dental protezler, Protezler ve implantlar, CAD/CAM, Dental implant, Internal adaptation, Marginal fit, Fixed partial denture, Dental implantation, Dental implants, Dental prosthesis, Prostheses and implants
- Yıl: 2020
- Dil: Türkçe
- Üniversite: Recep Tayyip Erdoğan Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Bu çalışmanın amacı, implant destekli sabit protezlerde farklı teknik ve malzemeler kullanılarak üretilen altyapıların marjinal ve internal uyumunu karşılaştırmaktır. Gereç ve Yöntem: Kısmi dişsizliği temsil etmek amacıyla epoksi rezinden hazırlanmış alt çene modeli üzerindeki 35 ve 37 numaralı dişler bölgesine iki adet dental implant yerleştirildi ve üzerine simante dayanaklar vidalandı. Elde edilen ana model laboratuvar tarayıcısı ile tarandı ve altyapı üretimi için tasarım programına aktarıldı. Altı farklı altyapı tipi için her gruptan 10'ar tane olmak üzere toplam 60 adet altyapı üretildi (n=10). Grup 1; Geleneksel döküm yöntemi ile üretilen Co-Cr altyapıyı (kontrol), Grup 2; CAD/CAM freze ile üretilen Co-Cr altyapıyı, Grup 3; Direk metal lazer sinterizasyonu (DMLS) ile üretilen Co-Cr altyapıyı, Grup 4; CAD/CAM ile üretilen titanyum altyapıyı, Grup 5; CAD/CAM ile üretilen zirkonyum altyapıyı ve Grup 6; CAD/CAM ile üretilen polietereterketon (PEEK) altyapıyı temsil etmektedir. Marjinal ve internal uyumu değerlendirmek için silikon replika tekniği kullanıldı. Altyapıların marjinal ve internal uyum değerlendirmeleri stereomikroskop ile yapıldı. Bu görüntülerden elde edilen marjinal ve internal aralık değerleri için gruplar arası karşılaştırmalar tek yönlü ANOVA testi ve Tukey's Post Hoc testi (çoklu karşılaştırma testi) ile, destek dişler arasındaki farklılıklar ise İndependent T testi (bağımsız örneklem t testi) ile gerçekleştirildi. Sonuçlar p˂0.05 anlamlılık düzeyinde değerlendirildi. Bulgular: Çalışma sonuçlarına göre, marjinal aralık ölçümlerinde PEEK ile titanyum grupları arasındaki istatistiksel olarak anlamlı fark bulunurken (p˂0.05), diğer gruplar arasında istatistiksel olarak anlamlı fark bulunmadı (p˃0.05). İnternal aralık ölçümlerinde, PEEK ile DMLS ve CAD/CAM freze ile üretilen Co-Cr grupları arasında istatistiksel olarak anlamlı fark bulunurken (p˂0.05), diğer gruplar arasındaki fark istatistiksel olarak anlamlı bulunmadı (p˂0.05). Destek dişler arasında ise sadece titanyum grupları arasında istatiksel olarak anlamlı fark bulunurken (p˂0.05), diğer gruplar arasındaki fark istatiksel olarak anlamlı bulunmadı (p˂0.05). Sonuç: Geleneksel döküm ve CAD/CAM teknikleri ile üretilen tüm altyapıların marjinal ve internal uyum değerlerinin literatürde kabul edilen klinik sınır değerler içinde olduğu tespit edildi.
Özet (Çeviri)
Purpose: The purpose of this study was to compare the marginal fit and internal adaptation of frameworks produced with different techniques in implant supported fixed partial denture. Material and Method: In order to exemplify the partial edentulism, two dental implants were implanted into the teeth region number 35 and 37 on the lower jaw made of epoxy resin, and then cemented abutments were screwed on the implants. The obtained master model was scanned by the laboratory scanner and transferred to the design programme for the production of the framework. For six different types of frameworks, totally sixty pieces of frameworks were produced having ten of each group (n=10). These frameworks were produced by using different CAD/CAM systems. Group 1 represents the Co-Cr framework produced by using traditional metal casting method (control group). Group 2 represents the Co-Cr framework produced by using CAD/CAM milling. Group 3 represents the Co-Cr framework produced by direct metal laser sintering (DMSL). Group 4 represents the titanium (Ti) framework produced by CAD/CAM. Group 5 represents zirconium (Zr) framework produced by CAD/CAM. Group 6 represents the polyether ether ether ketone (PEEK) framework produced by CAD/CAM. The silicone replica technique was implemented so as to evaluate the marginal and internal adaptation of the frameworks. The measurements for evaluation was carried out by a stereomicroscope (at ×20 magnification). An intergroup comparison was made in concern with the marginal and internal gap obtained from the photomicrographs. Intergroup comparisons were made by using ANOVA test and Tukey's Post Hoc Test (multiple comparison test). As for the differences between the abutment teeth, Independent T Test was carried out. Results were evaluated at a significance level of p<0.05. Results: According to the result of this study, significant differences were observed between PEEK and titanium groups in the marginal gap (p<0.05). On the other hand a statistically significant difference was not found among the other groups (p>0.05). A significant difference in the measurement of internal gap was found among the groups of PEEK, DMLS and Co-Cr framework produced by CAD/CAM milling (p<0.05), whereas no significant difference was found among the other groups (p>0.05). However, only for the titanium groups statistically significant difference was observed in abutment teeth (p<0.05), no significant difference was found among the other groups (p>0.05). Conclusion: All of the marginal and internal adaptation values, which were acquired by traditional metal casting method and CAD/CAM techniques, were within the clinical limit values as affirmed in the literature.
Benzer Tezler
- Tek seans CAD-CAM blokların farklı siman sistemleri ve yaşlandırma işlemi sonrasında dentine bağlanma dayanımının in vitro olarak değerlendirilmesi
Evaluation of dentin bondi̇ng strength in vitro after different cement systems and aging of chair-side CAD-cam blocks
SEDA ÜSTÜN
Diş Hekimliği Uzmanlık
Türkçe
2019
Diş HekimliğiKaradeniz Teknik ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. ELİF AYDOĞAN AYAZ
- Farklı yüzey uygulamalarının ve farklı rezin simanların cad/cam freze tekniği ile üretilen zirkonya post sisteminde retansiyona ve dirence etkilerinin invitro olarak değerlendirilmesi
Evaluating the effects of different surface treatments and different resin luting agents in the zirconia post system which produced by CAD/CAM copy-milling fabricating techniques for retention and resistance: Invitro study
DERYA TOPRAK
Doktora
Türkçe
2011
Diş HekimliğiDicle ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. ZELAL SEYFİOĞLU POLAT
- Architecture of constraints: A mass customization oriented approach for housing design
Kısıtlarla tanımlanan mimarlık: Kitlesel özelleştirme odaklı konut tasarımı
BENGİSU İLKSOY
Yüksek Lisans
İngilizce
2015
Mimarlıkİstanbul Teknik ÜniversitesiMimarlık Ana Bilim Dalı
DOÇ. DR. MİNE ÖZKAR KABAKÇIOĞLU
- Bilyalı anahtar şifreleme makinası konstrüksiyonu
Key bitting machine design
UMUT MURAT GÖK
Yüksek Lisans
Türkçe
2011
Makine Mühendisliğiİstanbul Teknik ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
YRD. DOÇ. DR. VEDAT TEMİZ
- Ergitmeli yığma yöntemiyle üretim yapan 3D yazıcılarda çift filament süren ekstruder tasarımı
Double filament extruder design for 3D fused deposition modelling printer
KEMAL OKTAY
Yüksek Lisans
Türkçe
2015
Mühendislik Bilimleriİstanbul Teknik ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
YRD. DOÇ. DR. VEDAT TEMİZ