Geri Dön

Bilgisayarlı tomografi ile optik sinir kılıf çapı ölçümünde acil tıpta uzmanlık öğrencilerinin değerlendiriciler arası güvenilirliğinin araştırılması

Interrater reliability of emergency medicine residents in measurement of optic nerve sheath diameter with computed tomography

  1. Tez No: 637136
  2. Yazar: İREM OLCAY YILMAZ
  3. Danışmanlar: PROF. DR. ERSİN AKSAY
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Nöroloji, İstatistik, Neurology, Statistics
  6. Anahtar Kelimeler: Acil tıp, Beyin, Güvenilirlik, Optik sinir, Tomografi-x ışınlı-bilgisayarlı, Tıpta uzmanlık eğitimi, İntörnlük ve asistanlık, Emergency medicine, Brain, Reliability, Optic nerve, Tomography-x ray-computed, Internship and residency
  7. Yıl: 2020
  8. Dil: Türkçe
  9. Üniversite: Dokuz Eylül Üniversitesi
  10. Enstitü: Tıp Fakültesi
  11. Ana Bilim Dalı: Acil Tıp Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Giriş ve Amaç Optik sinir kılıf çapının (OSKÇ) kafa içi basıncını artıran durumlarda arttığı ve bu artışın kötü klinik sonlanımla ilişkili olduğu bilinmektedir. Ölçüm sonuçlarının kişiler arasında farklılık gösterebilmesi nedeniyle, son yıllarda ultrasonografik ölçümlerde değerlendiriciler arası güvenilirlik çalışmaları yapılmaya başlandı. Biz, Medline taramamızda birincil sonlanım olarak bilgisayarlı tomografi ile OSKÇ ölçümlerinde değerlendiriciler arası güvenilirlik belirlemeyi hedefleyen bir çalışma bulamadık. Bu çalışmamızda birinci amacımız bilgisayarlı beyin tomografisinde OSKÇ ölçümünde acil tıpta uzmanlık öğrencilerinin değerlendiriciler arası güvenilirliğinin araştırılması, ikinci amacımız ise değerlendiriciler arası güvenilirliğe etki eden faktörleri ortaya koymak ve altın standart kabul edilen radyolojik ölçümle olan uyumunu değerlendirmektir. Gereç ve Yöntem Çalışmamızda OSKÇ artmış (≥5.5 mm) ve OSKÇ normal olan toplam 20 bilgisayarlı beyin tomografisinde 12 acil tıpta uzmanlık öğrencisi (altı kıdemli, altı kıdemsiz) ve bir radyoloji öğretim üyesi tarafından OSKÇ ölçüldü. Acil tıpta uzmanlık öğrencilerinin, aksiyel ve sagittal beyin tomografisi kesitlerinde ölçtükleri OSKÇ değerlerinin, kendi aralarında karşılaştırılarak değerlendiriciler arası güvenilirliği ve radyoloji öğretim üyesi tarafından yapılan ölçümlerle karşılaştırılarak tanısal doğruluğu belirlendi. Değerlendiriciler arası güvenilirlik intraclass coefficients correlations (ICC), kategorik değişimlerde uyum düzeyi ise kappa (ĸ) analizleri yapılarak hesaplandı. ATUÖ'nin yaş ortalaması ve yapılan ölçümlerin normal dağılıma uygunluğu Kolmogorov-Smirnov testi ile belirlendi. Normal dağılıma uyan veriler ortalama ile, uymayan veriler ortanca ve IQR (çeyreklikler arası genişlik) ile gösterildi. Tüm analizler %95 güven aralığında değerlendirildi ve p değeri <0.05 istatistiksel anlamlı değişiklik olarak kabul edildi. Bulgular Acil tıpta uzmanlık öğrencilerinin OSKÇ ölçümünde değerlendiriciler arası güvenilirliğini 'iyi' (ICC 0.798; %95 GA 0.777-0.818) düzeyde bulduk. Kıdemli acil tıpta uzmanlık öğrencilerinin değerlendiriciler arası güvenilirliğini 'iyi' (ICC 0.824; %95 GA 0.781-0.858), kıdemsiz acil tıpta uzmanlık öğrencilerinin değerlendiriciler arası güvenilirliğini 'orta' (ICC 0.748; %95 GA 0.687-0.797) düzeyde bulduk. Değerlendiriciler arası güvenilirlik aksiyel kesitten yapılan ölçümlerde 0.812 (%95 GA 0.7833-0838) ve sagittal kesitten yapılan ölçümlerde 0.783 (%95 GA 0.750-0.813) idi. Acil tıpta uzmanlık öğrencilerinin ölçümleri, radyoloji öğretim üyesi ölçümleriyle karşılaştırıldığında; değerlendiriciler arası güvenilirliği 'iyi' (ICC 0.891; %95 GA 0.865-0.911); uyumu ise 'iyi' (ĸ:0.688; p<0.001) düzeyde bulduk. Sonuç Acil tıpta uzmanlık öğrencilerinin bilgisayarlı beyin tomografisinde yaptıkları OSKÇ ölçümleri kendi içerisinde iyi derecede güvenilirdir, altın standart ölçümleri ile iyi derecede uyumludur. Acil tıpta uzmanlık öğrencileri, bilgisayarlı beyin tomografisi görüntülerinde güvenilir bir şekilde OSKÇ ölçümü yapabilir.

Özet (Çeviri)

Introduction It is known that optic nerve sheath diameter enlargement relates with increased intracranial pressure; also worsened clinical outcome. Due to differences between measurements among raters, recently there are some studies which evaluates interrater reliability with ultrasonographical techniques. We were unable to find a study which aims interrater reliability as primary outcome in measurement of optic nerve sheath diameter with computed brain tomography in Medline search. In this study our primary aim is evaluating interrater reliability in measurement of optic nerve sheath diameter with computed brain tomography, our secondary aim is determining the factors that affects interrater reliability and define reliability to the measurement of faculty of radiology which is gold standard. Materials and Methods Measurements of 10 enlarged optic nerve sheath diameter (≥5.5 mm) and 10 normal optic nerve sheath diameter (<5.5 mm) on brain computed tomography had been performed by one faculty of radiology and 12 residents of emergency medicine (six seniors, six juniors) from axial and sagittal planes of the left eye, behind 3 mm of optic disc. Interrater reliability of measurements of post graduate residents and their accuracy to the gold standard had been defined. measurements were made either sagittal or axial computed tomography plain, with normal and enlarged optic nerve sheath diameter. Interrater reliability is calculated using intraclass coefficients correlations (ICC), reliability on categorical variable is analyzed with kappa (ĸ). Mean age of post-grad residents and relevance of measurements to normal distribution had been defined by Kolmogorov-Smirnov test. The data that relates to normal distribution are shown by mean, and unrelated data are shown by median and IQR. All analysis were made in 95% confidence interval and p value <0.05 is statistically significant. Results We found that the interrater reliability is 'good' (ICC 0.798; 95 CI 0.777-0.818) among emergency medicine physicians in optic nerve sheath diameter measurements. Interrater reliability is 'good' (ICC 0.824; 95% CI 0.781-0.858) among senior physicians and 'moderate' (ICC 0.748; 95% CI 0.687-0.797) among junior residents. Interrater reliability among residents is; 0.812 (95% CI 0.7833-0838) on axial plane, 0.783 (95% CI 0.750-0.813) on sagittal plane. Interrater reliability between faculty of radiology and residents was found 'good' (ICC 0.891; 95% CI 0.865-0.911), accuracy is 'good' (ĸ:0.688; p<0.001). Conclusion Optic nerve sheath diameter measurements of post-grad residents on computed brain tomography highly reliable in itself, and they are well compatible with the gold standard measurements. Emergency medicine physicians can reliably measure optic nerve sheath diamter on computed brain tomography images.

Benzer Tezler

  1. Acil servise başvuran non-travmatik subaraknoid kanamalı olgularda optik sinir kılıf çapının mortalite ile ilişkisi

    Relation of optic nerve sheath diameter with mortality in non-traumatic subarachnoid hemorrhagic patients presenting to the emergency department

    AHMET YILMAZ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2020

    NöroşirürjiOndokuz Mayıs Üniversitesi

    Acil Tıp Ana Bilim Dalı

    PROF. DR. AHMET BAYDIN

  2. Acil servise başvuran üremik ensefalopatili hastalarda bilgisayarlı tomografi ile optik sinir kılıf çapı ölçümünün prognostik değerliliği

    Başlık çevirisi yok

    AYÇA ESRA BALTACIOĞLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2023

    Acil TıpSağlık Bakanlığı

    Acil Tıp Ana Bilim Dalı

    DOÇ. DR. GÜLŞEN ÇIĞŞAR

  3. Acil servise baş ağrısı şikayeti ile başvuran hastalarda optik sinir kılıf çapı ölçümünün bilgisayarlı beyin tomografisi çekim kararı verilmesindeki tanısal rolü

    Diagnostic role of optic nerve sheath diameter measurement in decision making computed brain tomography in patients presenting with headache in emergency department

    AYŞEGÜL İŞLEK YÜKSEL

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2019

    İlk ve Acil YardımSağlık Bilimleri Üniversitesi

    Acil Tıp Ana Bilim Dalı

    ÖĞR. GÖR. FATİH SELVİ

  4. Acil servise başvuran hastaların bilgisayarlı tomografi ile ölçülen optik sinir kılıf çapının normal ve patolojik bulgular arasındaki farkın belirlenmesi

    Determination of the difference between normal and pathological findings of optic nerve sheath diameter measured by computerized tomography of patients applying to the emergency room

    İLKER ŞALLI

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2020

    İlk ve Acil YardımDokuz Eylül Üniversitesi

    Acil Tıp Ana Bilim Dalı

    DOÇ. DR. RIDVAN ATİLLA

  5. Acil servise iskemik inme ile başvuran hastalarda bilgisayarlı beyin tomografisinde optik sinir kılıfı çapı ölçümünün prognozu öngörmede etkinliği

    Effectiveness of measuring optic nerve sheath diameter in predicting prognosis at computerized brain tomography in patients admitted to the emergency department with ischemic stroke

    CEM ÇİMEN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2021

    İlk ve Acil YardımSağlık Bilimleri Üniversitesi

    Acil Tıp Ana Bilim Dalı

    DOÇ. DR. MEHMET NURİ BOZDEMİR