Geri Dön

Farklı yöntemlerle üretilmiş nikel titanyum döner aletlerin kanal içi sıcaklıkta döngüsel yorgunluk dirençlerinin karşılaştırılması

Comparison of cyclic fatigue resistance of rotary nickel titanium instruments produced by different manufacturing methods at intracanal temperature

  1. Tez No: 628037
  2. Yazar: GÖZDE BAŞ
  3. Danışmanlar: PROF. DR. UĞUR İNAN
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Hyflex EDM, WaveOne Gold, OneCurve, Döngüsel yorgunluk, Statik test modeli, Nikel Titanyum, Dental aygıtlar, Kök kanal tedavisi, Metal yorgunluğu, Nikel, Titanyum, Hyflex EDM, WaveOne Gold, OneCurve, Cyclic fatigue, Static test model, Nickel-Titanium, Dental instruments, Root canal therapy, Metal fatique, Nickel, Titanium
  7. Yıl: 2020
  8. Dil: Türkçe
  9. Üniversite: Ondokuz Mayıs Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Endodonti Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Farklı yöntemlerle üretilmiş NiTi tek eğe döner sistemlerin kanal içi sıcaklıkta döngüsel yorgunluğa bağlı kırılma dirençlerinin karşılaştırılmasıdır. Materyal ve Metot: Çalışma kapsamında HyFlex EDM, WaveOne Gold ve One Curve döner eğe sistemlerinin her birinden 20'şer adet olmak üzere toplamda 60 adet eğe kullanıldı. Tüm eğeler statik model döngüsel yorgunluk deney düzeneğinde, 60°'lik kurvatür açısına, 5 mm yarıçapa ve 1,4 mm kanal iç çapına sahip seramik yapay kanallarda ve 37°C'de kırılıncaya kadar kullanıldı. Eğelerin kırılma zamanı dijital kronometre ile kaydedildi ve dönme hızı ile çarpılarak kırılıncaya kadarki tur sayıları sayısal olarak hesaplandı. Kırık yüzeyler kırık tipinin belirlenmesi amacıyla taramalı elektron mikroskobu ile incelendi ve eğelerin faz transformasyon sıcaklıkları ise diferansiyel taramalı kalorimetre cihazında analiz edildi. Normal dağılım göstermediği saptanan verilerin analizi için Kruskal-Wallis H testi uygulandı. Weibull analizi yapılarak eğelerin tahmini sağlam kalma oranı belirlendi. Bulgular: Çalışmamızın istatiksel analiz sonuçlarına göre, kırılıncaya kadar geçen süre ve ortalama tur sayıları bakımından her 3 eğe grubu arasında anlamlı fark bulunmuştur (p<0.05). Eğelerin döngüsel yorgunluk dirençleri yüksekten düşüğe; Hyflex EDM, WaveOne Gold, One Curve olarak sıralanmıştır. SEM kullanılarak yapılan kırık yüzeylerin analizi ile kırılmaların döngüsel yorgunluk sonucu oluştuğu belirlenmiştir. DSC analizi ise, HyFlex EDM eğelerin klinik koşullarda tamamen martensit fazda olduğunu, austenit faz içermediğini göstermiştir. WaveOne Gold ve One Curve eğeler ise austenit, R-fazı ve martensit faz içermektedir. Sonuç: Çalışmamızın sonucuna göre üretim şekilleri, alaşımın özellikleri ve eğelerin kanal içi sıcaklıkta hangi fazda bulundukları gibi faktörler eğelerin döngüsel yorgunluk direncini etkilemektedir.

Özet (Çeviri)

Aim: To compare the cyclic fatigue resistance of NiTi single file rotary systems, produced using different methods at the intracanal temperature. Material and Methods: In this study, total of 60 files were used- 20 files each from Hyflex EDM, WaveOne Gold and One Curve rotary systems. All files were rotated using a static-model cyclic-fatigue testing device within an artificial ceramic canal with a 60° angle of curvature, 5 mm radius of curvature and 1.4 mm internal diameter at 37°C. The time to fracture of the files was recorded with a digital chronometer and the number of cycles to fracture was calculated by multiplying the time to fracture and rotations per minute. The fracture faces of the files were examined using a scanning electron microscope (SEM) to determine the fracture type and the phase-transformation temperatures were analyzed using a differential scanning calorimeter (DSC). Kruskal-Wallis H test was used for the data that were not normally distributed. The probability of survival for each file group was determined using Weibull analysis. Results: According to statistical analysis conducted in this study, significant differences among three file groups were found in terms of time and mean number of cycles to fracture (p<0.05). The order of cyclic fatigue resistance of the files, from highest to lowest, was Hyflex EDM, WaveOne Gold and One Curve. Fractographic analysis with SEM confirmed that the cause of fracture was cyclic fatigue. DSC analysis showed that Hyflex EDM files were martensitic at clinical conditions and did not include austenite phase. WaveOne Gold and One Curve files included austenite, R-phase and martensite phases. Conclusion: Our study found that factors such as manufacturing methods, alloy properties and the phase of the files at the intracanal temperature affect the cyclic fatigue resistance.

Benzer Tezler

  1. Farklı yöntemlerle üretilmiş orijinal ve muadil döner sistem eğelerin standardizasyon ve döngüsel yorgunluk dirençlerinin karşılaştırılması

    Comparison of standardization and cyclic fatigue resistance of original and replica-like files produced by different manufacturing methods

    MÜBERRA KARADAYI

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2024

    Diş HekimliğiOndokuz Mayıs Üniversitesi

    Endodonti Ana Bilim Dalı

    PROF. DR. UĞUR İNAN

  2. Doğal gaz boru hatlarında orbital kaynak teknolojisi kullanılarak yapılan kaynakların mekanik ve mikroyapı özelliklerinin incelenmesi

    Characterization of microstructure and mechanical properties of girth welds welded with orbital welding technology in the natural gas pipelines

    HANİFE DİDEM GENÇKAN

    Doktora

    Türkçe

    Türkçe

    2014

    Metalurji Mühendisliğiİstanbul Teknik Üniversitesi

    Metalurji ve Malzeme Mühendisliği Ana Bilim Dalı

    PROF. DR. FİLİZ ŞAHİN

  3. Endodontide kullanılan nikel–titanyum esaslı kullanılmış döner diş eğelerinden metalik değerlerin geri kazanımı

    Recovery of metallic values from disposed nickel–titanium rotary endodontic files

    MUHAMMED İHSAN ÖZGÜN

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    Metalurji Mühendisliğiİstanbul Teknik Üniversitesi

    Metalurji ve Malzeme Mühendisliği Ana Bilim Dalı

    PROF. DR. MAHMUT ERCAN AÇMA

    DR. ÖĞR. ÜYESİ YASİN RAMAZAN EKER

  4. Magnezyum alaşımlarının farklı yöntemlerle hidroksiapatit kaplanarak korozyon hızının belirlenmesi

    Corrosion behaviour of ha coatings on AZ31 and AZ91 magnesium alloys

    SERKAN BAŞLAYICI

    Doktora

    Türkçe

    Türkçe

    2021

    Metalurji Mühendisliğiİstanbul Teknik Üniversitesi

    Metalurji ve Malzeme Mühendisliği Ana Bilim Dalı

    PROF. DR. MAHMUT ERCAN AÇMA

  5. Titanyum kaynağı ve mekanik özellikler üzerine etkisinin incelenmesi

    Titanium welding and investigation of effect on mechanical properties

    MURAT SÖNMEZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Mühendislik Bilimleriİstanbul Gedik Üniversitesi

    Savunma Teknolojileri Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ POLAT TOPUZ