İmplant hastalarında iki farklı konik ışın demetli bilgisayarlı tomografi ve ultrasonografi ile implant bölgesi diş eti dokularının değerlendirilmesi
Accuracy of high resolution ultrasound for soft tissue thickness mesurementin edentulous patients prior to implant placement
- Tez No: 624691
- Danışmanlar: PROF. DR. KIVANÇ KAMBUROĞLU
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Dental implantasyon, Dental implantlar, Gingiva, Konik ışınlı bilgisayarlı tomografi, Ultrasonografi, Dental implantation, Dental implants, Gingiva, Cone-beam computed tomography, Ultrasonography
- Yıl: 2019
- Dil: Türkçe
- Üniversite: Ankara Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Ağız, Diş ve Çene Radyolojisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Giriş: Yumuşak doku kalınığını ölçmek için, histolojik kesit alma, periodontal sond, endodontik eğeler veya enjeksiyon iğnesi kullanarak transgingival sondlama gibi pek çok invaziv tenik kullanılmıştır. Son yıllarda bilgisayarlı tomografi (BT), konik ışın demtli bilgisayarlı tomografi ve ultrasonografi gibi non-invaziv yöntemler olarak yumuşak doku kalınlığı belirlemede kullanılmıştır. Bu çalışmanın amacı, dişsiz hastalarda implant yerleştirilmesi öncesinde yumuşak doku kalınığı ölçümünde, yüksek çözünürlüklü US'nin etkinliğinin değerlendirlmesi ve iki farklı KIBT cihazı ve klinik periodontal değerlendirme ile karşılaştırılmasıdır. Gereç ve Yöntem: 40 adet implant bölgesine ait dişeti kalınlığı (16 anterior ve 14 posterior) dar görüntüleme alanına sahip KIBT görüntüleri ve US görüntüleri periodontal sond ölçümleri ile karşılaştırılarak prospektif olarak değerlendirilmiştir.20 hasta'nın KIBT görüntüleri Planmeca Promax 3D max KIBT cihazı (Planmeca, Helsinki, Finlandiya) ile diğer 20 hastanın KIBT görütüleri Morita 3D Accuitomo 170® KIBT cihazı (J Morita, Kyoto, Japonya) ileakrilik dudak ekartörü kullanılarak elde edilmiştir. Herbir implant bölgesinin, bukkal yumuşak doku kalınlığı alveoler krete dik olarak ölçülmüştür ve her bir implant bölgesi için alveolar kret tepesi ve tabanında2 ölçüm gerçekleştirilmiştir. US incelemesi ACUSON S 2000 (Siemens, Munich, Germany) yüksek çözünürlüklü ultrasonografi cihazı ile yapılmıştır. İnceleme sırasında 15 MHz hokey sopası prob kullanılarak longitudinal düzlemde, prob pozisyon sürekli değiştirilerek yeterli kalitede krosseksiyonel görüntü elde edilene kadar yapılmıştır. Her implant bölgesi için metrik ölçümler KIBT görüntülerinde değerlendirilen aynı noktalarda gerçekleştirilmiştir. Her bir implant bölgesi yumuşak doku kalınğı aynı referans noktalarda klinik olarak, enjeksiyon iğnesi ve yumuşak silikon disk yardımıyla lokal anestezi altnda ölçülmüştür. 3 farklı teknik kullanarak elde edilen yumuşak doku kalınlığı ölçümleri, tek yönlü varyans analizi ile değerlendirilmiştir. Altın standart yöntemi olan klinik ölçüm ile ultrasonografi ve KIBT ölçüm (Morita ve Planmeca) grupları arasındaki ölçüm farklarının dağılımı Tek Örneklem Testi ile incelendi. Analizler için SPSS 14.01 paket programından yararlanıldı. Tüm istatistiksel kararlarda P<0.05 ölçütü kullanıldı. Bulgular: Transgingival sondlama, KIBT ve US görüntülerinde tepe ve taban bölgesi için elde edilen ortalama diş eti kalınlığı ölçümleri karşılaştırıldığında, her iki bölge için istatiksel olrakak alamlı fark bulunamamıştır(p=0.519 ve p=0.346). Teknikler arası uyum göz önüne alındığında, klinik ölçüm ile ultrasonografi görüntülerinden elde edilen ölçümler arasında istatiksel olarak anlamlı fark tespit edilememiştir(p>0.05). Ancak taban bölgesi ölçümleri için, klinik yöntem ile Morita KIBT cihazı ile elde edilen ölçümler arasında istatiksel olarak anlamı fark tespit edilmiştir(p=0,014). Buna ek olarak tepe bölgesi için, klinik yöntem ve her iki KIBT cihazı(Planmeca ve Morita) ile elde edilen ölçümler arasında istatiksel olarak anlamlıfark bulunmuştur (p=0,012 ve 0,018). Sonuç: Yüksek çözünürlüklü ultrasonografi, dişsiz hastalarda implant yerleştirilmesi öncesinde yumuşak doku kalınlık ölçümlerinde doğru ölçümler sağlamıştır. Düşük maliyet, non-invaziv ve non-iyonize doğası gereği ultrasonografik görüntüleme, implant bölgesi yumuşak dokuların değerlendirilmesinde umut vadeden bir tekniktir.
Özet (Çeviri)
Introduction: Various invasive methods have been utilized in order to measure soft tissue thickness, such as; histological sectioning, transgingival probing by using a periodontal probe, using an endodontic reamer or an injection needle under local anesthesia. Recently, computerized tomography (CT), cone beam computerized tomography (CBCT) and ultrasonography have been used as non-invasive methods for the measurement of soft tissue thickness. Our aim was therefore to evaluate and compare the accuracy of high resolution US by usingtwo different CBCT units and clinical periodontal assessment for measuring soft tissue thickness in edentulous patients prior to implant placement. Materials and Methods: We prospectively evaluated gingival thickness in 40 implant region (16 anterior and 14 posterior) by using limited FOV CBCT images and US images in comparison with periodontal sond measurements.CBCT images of 20 patient were obtained by using a Planmeca Promax 3D max CBCT unit (Planmeca, Helsinki, Finland) and CBCT images of other 20 patients were obtained by using Morita 3D Accuitomo 170® (J Morita, Kyoto, Japan) with an acrylic lip retractor placed. For each implant site, soft tissue thickness measurements were performed at 2 different points; top of alveolar crest and bottom of alveolar crest on CBCT images by using inbuilt software. US examinations were conducted by using an ACUSON S 2000 (Siemens, Munich, Germany) with a 15MHz hockey probe on the longitudinal plane, with the probe position changed constantly to obtain sufficient crossectional images on the monitor. For each implant site, metric measurement of soft tissue thickness was performed at the same 2 points that were already calculated on CBCT images. Thicknesses of the soft tissues of each implant site were also measured clinically at the same reference points by using an injection needle with a stopper. Soft tissue thickness obtained by using 3 different techniques were compared with one way variance analysis. In order to compare measurement differences between techniques one sample t-test was used. All statiscal analysis were performed by using SPSS 14.01. Significance level was set P<0.05. Results: There was no statistically significant differences between CBCT, US imaging and transginvival probing for both measurements obtain from top (p=0.519). and bottom(p=0.346) of alveolar crest measurements. When agreement between different techniques for measuring soft tissue thickness was taken into consideration, no statistically significantdifferences were found between clinical measurements and US measurements(p>0.05). However there were statistically significant differences between clinical measurements and CBCT measurements obtained with Morita CBCT unit for measurements conducted at the bottom of alveolar crest (p=0,014). In addition, statistically significant differences were found between clinical measurements and CBCT measurements 65 obtained from both CBCT units (Planmeca and Morita) for measurements conducted at the top of alveolar crets(p=0,012 and 0,018). Conclusion: High resolution US provided accurate information for the measurement of soft tissue thickness in edentulous patients prior to implant placement. Due to it is low cost, non- invasive and non-ionized nature, US imaging is a promising technique, for preoperative soft tissue evaluation implant site.
Benzer Tezler
- Farklı verici sahalardan alınan bağ dokusu greftinin immediyat implantasyonda peri-implanter dokular üzerine etkisinin değerlendirilmesi
Evaluation of the effect of different connective tissue donor sites on peri-implant tissues in immediate implantation
ŞİVE ERCAN
Doktora
Türkçe
2017
Diş HekimliğiEge ÜniversitesiPeriodontoloji Ana Bilim Dalı
PROF. DR. AHMET TUNÇ İLGENLİ
- Deneysel diabetiklerde ER:YAG lazerin kemik üzerine etkisinin histolojik incelenmesi
Histologic evaluation of the effects of ER:YAG laser on bone in experimental diabetics
UTKAN AKYOL
Doktora
Türkçe
2008
Diş HekimliğiAtatürk ÜniversitesiAğız, Diş ve Çene Cerrahisi Ana Bilim Dalı
DOÇ. DR. METİN GÜNGÖRMÜŞ
- Agresif periodontitis hastalarında implant çevresi kemik seviyelerinin uzun dönem takibi
Long-term evaluation of dental implants in patients treated for aggressive periodontitis
IŞIL MİNOĞLU ŞAYLAN
Doktora
Türkçe
2010
Diş Hekimliğiİstanbul ÜniversitesiPeriodontoloji Ana Bilim Dalı
PROF. DR. ÖZEN TUNCER
- Üst çene arka grup dişsiz hastalarda görülen sinüs patolojilerinin konik ışınlı bilgisyarlı tomografi ve panoramik radyografi ile değerlendirilmesi
Evaluation of sinus pathologies seen in maxillary posterior edentulous patients with cone beam computed tomography and panoramic radiography
OĞUZHAN DEMİREL
Doktora
Türkçe
2015
Diş HekimliğiGazi ÜniversitesiAğız, Diş ve Çene Radyolojisi Ana Bilim Dalı
PROF. DR. CEMİLE ÖZLEM ÜÇOK
- Foramen zygomatıcofacıale'nin konik ışınlı bilgisayarlı tomografi görüntülerinde anatomik olarak incelenmesi
Anatomical investigation of zygomaticofacial foramen on cone beam computed tomography images
TUĞBA AY
Yüksek Lisans
Türkçe
2025
AnatomiGaziantep ÜniversitesiAnatomi Ana Bilim Dalı
PROF. DR. PİRAYE KERVANCIOĞLU
DR. ÖĞR. ÜYESİ SALİHA SEDA ADANIR