Geri Dön

Manyetik rezonans görüntüleme yapılan hastalarda gürültünün periferik işitme organına olası etkisinin otoakustik emisyon cihazı ile değerlendirilmesi

Evaluation of the possible effect of noise on theperipheral hearing organ on magnetic resonance i̇maging patients with autoacoustic emmission device

  1. Tez No: 609931
  2. Yazar: CEVAHİR BULUT TURAY
  3. Danışmanlar: PROF. DR. HATİCE SEYRA ERBEK
  4. Tez Türü: Yüksek Lisans
  5. Konular: Kulak Burun ve Boğaz, Otorhinolaryngology (Ear-Nose-Throat)
  6. Anahtar Kelimeler: Manyetik Rezonans Görüntüleme (MRG), İşitme Yüksek Frekans Odyometrisi, Transient Evoked Otoakustik Emisyon (TEOAE), Distorsion Product Otoakustik Emisyon (DPOAE), Distorsiyon, Gürültü, Manyetik rezonans görüntüleme, Odyometri, Otoakustik emisyonlar, İşitme, Magnetic Resonance Imaging (MRI), Hearing, High Frequency Audiometry, Transient Evoked Otoacoustic Emissions (TEOAE), Distortion Product Otoacoustic Emissions (DPOAE), Distortion, Noise, Magnetic resonance imaging, Audiometry, Otoacoustic emissions
  7. Yıl: 2020
  8. Dil: Türkçe
  9. Üniversite: Başkent Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Kulak Burun Boğaz Hastalıkları Ana Bilim Dalı
  12. Bilim Dalı: Odyoloji Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı, sağlıklı işiten bireylerde manyetik rezonans görüntüleme (MRG) gürültüsü maruziyeti öncesi ve sonrasında işitmeyi objektif ve subjektif odyolojik yöntemler ile değerlendirerek MRG cihazının yaydığı gürültünün işitme üzerine etkisini saptamaktır. Çalışmaya 18-50 yaş arası, otoskopik muayenesi ve timpanogramı normal olan, işitme kaybı olmayan toplam 38 hasta dahil edildi. Tüm hastaların muayeneleri yapıldıktan sonra MRG öncesi ve sonrası saf ses odyometrisi, konuşma odyometrisi yüksek frekans odyometrisi, transient evoked otoakustik emisyon (TEOAE) ve distorsion product otoakustik emisyon (DPOAE) testleri yapıldı. Çalışmamızda TEOAE, saf ses odyometrisi, konuşma odyometrisi, yüksek frekans odyometrisi sonuçları karşılaştırıldığında hastaların MRG öncesi ve sonrası, işitme eşiklerinde anlamlı bir farklılık gözlenmedi. DPOAE ölçümlerinde; 4 kHz frekansta sol kulakta MRG öncesi ortanca değeri 13,6 SNR iken MRG sonrası 15,7 SNR olarak bulunmuştur (p>0,05). Sağ kulakta ise MRG öncesi ortanca değeri 14,1 SNR iken MRG sonrası 13,2 SNR olarak bulunmuştur (p<0,05). Diğer frekanslarda ise MRG öncesi ve sonrası ölçümler arasında anlamlı fark bulunamamıştır. DPOAE ölçümleri sonucunda elde ettiğimiz 4kHz frekansındaki etkilenmeye göre MRG esnasında kullanılan kulak üstü kulaklıkların hastaları gürültüden korumada ne derece etkin olduğunun araştırılması gerektiğini düşünmekteyiz. MRG cihazının yarattığı gürültünün işitmeye olan etkisini tam olarak anlayabilmek daha kapsamlı çalışmalar yapılmalıdır.

Özet (Çeviri)

The aim of this study is to evaluate the effect of noise produced by magnetic resonance imaging (MRI) device on hearing by using objective and subjective audiological assesments. A total of 38 patients between the ages of 18 and 50, who had normal otoscopic examination and normal tympanogram wtihout hearing loss were included. After otoscopic examination; pure tone audiometry, speech audiometry, high requency audiometry, transient evoked otoacoustic emissions (TEOAE) and distortion product otoacoustic emission (DPOAE) tests were performed before and after MRI to all patients. There was no statistically significant differences in TEOAE, pure tone audiogram, high frequency audiogram and speech audiogram tresholds before and after MRI. DPOAE results at 4kHz were significantly differerent before and after MRI. On left ear median values were 13,6 and 15,7 before and after MRI consecutively. On the right ear median values were 14,1 and 13,2 before and after MRI consecutively. There was no statistically significant difference in other frequencies in DPOAE. Based on the difference at 4 kHz frequency on DPOAE; earphones may be sufficiently protect the patients from the MRI noise and this issue should deserve further research. In order to completely undertstand the effect of MRI noise on hearing; more comprehensive studies should be performed

Benzer Tezler

  1. Çok ince yapı teorisi

    Theory of hyperfine structure

    ŞEMSETTİN ALTINDAL

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Fizik ve Fizik MühendisliğiGazi Üniversitesi

    DOÇ. DR. ATİLLA ÖZMEN

  2. Manisa-Demirci-Köseler plaserinden titan minerallerinin kazanılması ve pigment üretimine katkı araştırmaları

    Recovery of the titanium minerals from Manisa-Demirci-Köseler plocer sands and examination of their use in prgment production

    SADULLAH ERTEKİN

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Kimya MühendisliğiGazi Üniversitesi

    Kimya Mühendisliği Ana Bilim Dalı

    DOÇ. DR. NİYAZİ DELİORMANLI

  3. Ni-B ikili alaşım sisteminde Ni zengin bazı ara fazların manyetik özellikleri

    Magnetic properties of some Ni rich intermediate phases in Ni-B binary alloy system

    R.HALUK MUTLU

    Doktora

    Türkçe

    Türkçe

    1987

    Fizik ve Fizik MühendisliğiAnkara Üniversitesi

    Fizik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ARSIN AYDINURAZ

  4. Nükleer magnetik rezonansın kuvantum ilkelerine giriş

    Başlık çevirisi yok

    H.HANDAN GÜRBÜZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Fizik ve Fizik Mühendisliğiİstanbul Üniversitesi

    Fizik Ana Bilim Dalı

    PROF. DR. HAYATİ BUDAK