İklimlendirilmesi yapılan bir mahalin hız ve sıcaklık dağılımının sayısal ve deneysel olarak incelenmesi

Numerical and experimental investigastion of velocity and temperature distrubution of an air conditioned room

  1. Tez No: 607376
  2. Yazar: ALPER YILDIRIM
  3. Danışmanlar: PROF. DR. COŞKUN ÖZALP
  4. Tez Türü: Doktora
  5. Konular: Makine Mühendisliği, Mechanical Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Osmaniye Korkut Ata Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Havanın odaya verilmesi, dağılması ve emişi menfez ve difüzörler ile sağlanmaktadır. Gerekli hesaplamalar yapıldıktan sonra doğru menfez seçilemez ise termal konfor sağlanamaz. Termal konfor problemi yaşayan binalara incelendiğinde sorunun büyük kısmının uygun olmayan menfez ve difüzör seçiminden kaynaklandığı görülmektedir. Bu da büyük maliyetler oluşturmaktadır. Bu tezde, boyutları 4x3x3,5 metre olan ofis odasını havalandırmak için farklı menfez ve difüzör tipleri (kare, slot, jet) kullanıldığı kabul edilmiştir. Termal konfor, zeminden 0,1, 0,6 ve 1,1 metre yükseklikteki ısıl rahatlık indisi (PMV) ve tahmin edilen yüzde memnuniyetsizliği (PPD) endeksleri ile incelenmiştir. Bu incelemeler hesaplamalı akışkanlar dinamiği (HAD) ile sayısal olarak çözülmüştür. Çözümlemelerde RNG k – ε türbülans modeli kullanılmıştır. Menfez hava çıkış hızı 2,5 m/s olarak hesaplanmış ve odaya klima santrali ile %100 taze hava verildiği kabul edilmiştir. Osmaniye ili yaz şartlarına göre ısı kaybı/kazancı hesabı yapılmış buna göre mahalin duvarlarına, tabana ve tavana ısı akısı verilmiştir. Oda içerisinde buzdolabı, lamba, insan bulunduğu kabul edilerek bunlara da ısı akısı verilmiştir. PMV ve PPD değerleri hesaplanırken hız ve sıcaklık değeri HAD ile hesaplanmış, aktivite seviyesi (metabolik oran), ortalama ışınım sıcaklığı kıyafet termal direnci, bağıl nem değerleri sabit alınmıştır. Farklı menfezlerden elde edilen PMV ve PPD değerleri birbiri ile kıyaslanmıştır. Kıyaslama sonucunda, kare menfezin termal konforu en çok sağladığı belirlenmiştir. Bu tezde ayrıca içerisinde jet nozul bulunan 1/10 ölçeğinde bir ofis modeli yapılarak Parçacık Görüntülemeli Hız Ölçüm (PIV) tekniği kullanarak ofis modeli içerisindeki akış analizi deneysel olarak incelenmiştir. Deneyden ve HAD' dan elde edilen hız değerleri karşılaştırılmış ve sonuçların uyumlu olduğu görülmüştür.

Özet (Çeviri)

The supply, distribution and suction of the air in the room are provided with grilles and diffusers. If the correct grille cannot be selected after the necessary calculations are made, thermal comfort cannot be provided. When the buildings with thermal comfort problems are examined, it is seen that the majority of the problem arises from the choice of inappropriate grills and diffusers. This creates huge costs. In this thesis, it is accepted that different grilles and diffusers (square, slot, jet) are used for ventilation to the office room which is 4x3x3.5 meters in size. Thermal comfort was examined with the predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD) indices at 0.1, 0.6 and 1.1 meters above the ground. These investigations were solved numerically by computational fluid dynamics (CFD). RNG k - ε turbulence model was used in the analyzes. The vent air outlet velocity was calculated as 2.5 m / s and it was assumed that 100% fresh air was supplied to the room by the air handling unit. According to the summer conditions of Osmaniye, heat loss / gain was calculated and heat flux was given to the walls, floor and ceiling of the site. It was assumed that there were refrigerator, lamp and people in the room and they were given heat flux. While PMV and PPD values were calculated, velocity and temperature values were calculated from CFD program, activity level (metabolic rate), average radiation temperature, clothing thermal resistance, relative humidity values were taken constant. PMV and PPD values obtained from different grilles were compared with each other. As a result of the comparison, it was determined that the square grill provides the most thermal comfort. In this thesis, a 1/10 scale office model with a jet nozzle is used and the flow analysis in the office model is investigated experimentally using Particle Imaging Velocity Measurement (PIV) technique. Experimental and CFD velocity results are compatible

Benzer Tezler

  1. Bir mahalin fotovoltaik ve toprak hava ısı değiştirici destekli hava kaynaklı ısı pompası ile iklimlendirilmesi

    Air conditioning of a place with an air source heat pump supported by photovoltaic and earth air heat exchanger

    YUNUS DEMİRTAŞ

    Doktora

    Türkçe

    Türkçe

    2022

    EnerjiHarran Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. HÜSAMETTİN BULUT

  2. Model bir seranın iklimlendirilmesi ve otomasyonu

    Climatization and automation of a model greenhouse

    MURAT AYDINCİOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2004

    ZiraatYüzüncü Yıl Üniversitesi

    Tarım Makineleri Ana Bilim Dalı

    DOÇ.DR. TAMER UÇAR

  3. V-tipi bir stirling motorunun tasarımı ve imali

    Design and manufacturing of a v-type stirling engine

    ATİLLA KOCA

    Doktora

    Türkçe

    Türkçe

    1997

    Eğitim ve ÖğretimGazi Üniversitesi

    Makine Eğitimi Ana Bilim Dalı

    PROF. DR. BİLGE ERDİLLER

  4. A new approach to evaluate the nearly zero energy concept of EPBD recast at district scale

    EPBD recast'ın belirlediği yaklaşık sıfır enerji konseptinin yerleşim ölçeğinde değerlendirilmesi için yeni bir yaklaşım önerisi

    ECE KALAYCIOĞLU

    Doktora

    İngilizce

    İngilizce

    2017

    Mimarlıkİstanbul Teknik Üniversitesi

    Mimarlık Ana Bilim Dalı

    PROF. DR. AYŞE ZERRİN YILMAZ

  5. Investigation of thermal comfort parameters in bus design

    Otobüs tasarımında ısıl konfor değişkenlerinin incelenmesi

    ÜZEYİR PALA

    Doktora

    İngilizce

    İngilizce

    2014

    BiyoteknolojiFatih Üniversitesi

    Biyoteknoloji Ana Bilim Dalı

    PROF. DR. HALİL RIDVAN ÖZ

    PROF. DR. NADER NADA