Design and control of a pneumatically driven MRI-compatible tele operated haptic interface

Başlık çevirisi mevcut değil.

  1. Tez No: 588799
  2. Yazar: MELİH TÜRKSEVEN
  3. Danışmanlar: Dr. JUN UEDA
  4. Tez Türü: Doktora
  5. Konular: Makine Mühendisliği, Mechanical Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2016
  8. Dil: İngilizce
  9. Üniversite: Georgıa Instıtute Of Technology
  10. Enstitü: Yurtdışı Enstitü
  11. Ana Bilim Dalı: Belirtilmemiş.
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Özet yok.

Özet (Çeviri)

This thesis presents a pneumatically driven haptic interface for rehabilitation in MRI, and methods for understanding, modeling and control of tele-operated pneumatic actuators. Pneumatic actuators have excellent MRI-compatibility as opposed to conventional electro-mechanic systems. They are also desirable for their inherent compliance and easy-maintenance. However, the actuator and the system drivers cannot be co-located due to the MRI-compatibility requirements. The actuators are driven via long transmission lines, which a ect the system dynamics signi cantly, and the use of commercial pressure sensors are prohibited in MRI rooms. This thesis addresses these challenges in the tele-operation of the pneumatic actuators and introduces novel approaches to mitigate the adverse e ects of long transmission in pneumatic drive. An optical force sensor was designed and prototyped to enable force feedback from the actuator in the MR-scanner. Subsequent analysis on the sensing quality of the designed sensor improved its hysteresis characteristics. Based on the enabled force feedback, a non-linear observer that achieves asymptotical stability was designed. The developed observer was validated experimentally. Finally, a control algorithm that accounts for the pressure dynamics in the transmission lines was introduced. The performance of the controller and its contribution in the force control accuracy were tested on systems with various line lengths. The methods and tools developed in this research are expected to expand the range of applications of tele-operated pneumatic actuators, particularly on rehabilitation in MRI.

Benzer Tezler

  1. Kam yapma aparatı

    Cam milling attachment

    ORHAN UZUN

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Makine MühendisliğiGazi Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DOÇ. DR. FEVZİ ERCAN

  2. Osilaskoplar için dijital hafıza ünitesi sentezi

    Başlık çevirisi yok

    ZİHNİ LİMAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Elektrik ve Elektronik MühendisliğiUludağ Üniversitesi

    Elektronik Ana Bilim Dalı

    PROF. DR. ERGÜR TÜTÜNCÜOĞLU

  3. Helisel yayların statik karakteristiklerini ölçme ve kontrol etme cihazının tasarımı ve imalatı

    Design and manufacture of a device measuringand controlling the static characteristics of helical springs

    MUAMMER MUSULLUOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Makine MühendisliğiGazi Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DOÇ. DR. FEVZİ ERCAN

  4. Sonbahar sera yetiştiriciliğine uygun hıyar çeşit seçimi

    Selecting a cucumber variety suitable for glasshouse production in Autumn

    MESUT OKTAY

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    ZiraatEge Üniversitesi

    PROF. DR. AYTEN SEVGİCAN