Radyasyon tedavilerinde kullanılabilen bazı termolüminesans malzemelerin dozimetrik özelliklerinin incelenmesi

Investigation of dosimetric properties of some thermoluminescent materials used in radiation therapy

  1. Tez No: 586820
  2. Yazar: FATMA KAYA SOYKAN
  3. Danışmanlar: DR. ÖĞR. ÜYESİ MEHMET ALTAY ATLIHAN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Physics and Physics Engineering
  6. Anahtar Kelimeler: Radyasyon, Radyometri, Radyoterapi, Termolüminesans, X ışını, Radiation, Radiometry, Radiotherapy, Thermoluminescence, X ray
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Pamukkale Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Fizik Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu tez çalışmasında, radyasyon tedavilerinde yaygın bir şekilde kullanılan TLD-100 (LiF: Mg, Ti), TLD-200 (CaF2:Dy) ve TLD-400 (CaF2:Mn) termolüminesans malzemelerin dozimetrik özellikleri incelenmiştir. TLD'ler, RW3 katı su fantomu ve bolus ile hazırlanan sistem, lineer hızlandırıcı kullanılarak, 6-18 MeV enerjili x-ışınları (foton) ile 0.2 Gy, 1 Gy ve 5 Gy radyasyon dozlarında ışınlanmıştır. Işınlama öncesinde ısıl işlem, ışınlama, ışınlama sonrası ısıl işlem (ön ısıtma) ve lüminesans ölçümü (okuma) beşer defa uygulanarak, her bir dozimetre için element düzeltme (ECC) ve okuyucu kalibrasyon faktörü (RCF) katsayıları belirlenmiştir. Bu veriler kullanılarak, ışınlamalara karşılık gelen termolüminesans (TL) şiddetleri hesaplanmıştır. Elde edilen sonuçlara göre, TLD-100, TLD-200 ve TLD-400 dozimetrelerinin 0.2 Gy, 1 Gy ve 5 Gy doz aralığında lineer bir davranış sergiledikleri belirlenmiştir. 6-18 MeV enerjili x-ışınları ile üç farklı radyasyon doz değerlerinde yapılan ışınlamalar sonucunda elde edilen TL şiddeti verileri TL6MeV/TL18MeV şeklinde oranlandığı zaman, TLD-100 dozimetresinde oranların değiştiği görülmektedir. Buna rağmen, TLD-200 ve TLD-400 dozimetrelerinde oranlar değişmemektedir. Buradan, TLD-100 dozimetresinin enerji bağımlılığının bulunduğunu, TLD-200 ve TLD-400 dozimetrelerinin ise enerji bağımlılıklarının bulunmadığı anlaşılmaktadır. Bununla birlikte, TLD-200 dozimetresinin, TLD-100'den yaklaşık olarak 40 kat, TLD-400'den ise yaklaşık olarak 8 kat daha duyarlı olduğu belirlenmiştir. Son olarak, 6 MeV'den 18 MeV'e enerji değiştirildiğinde, bu enerji değişimine en yüksek duyarlılığı TLD-200/TLD-100 kombinasyonunun, en düşük duyarlılığı ise TLD-400/TLD-200 kombinasyonunun verdiği gözlemlenmiştir.

Özet (Çeviri)

In this thesis, the dosimetric properties of TLD-100 (LiF: Mg, Ti), TLD-200 (CaF2: Dy) and TLD-400 (CaF2: Mn) thermoluminescence materials which are widely used in radiation treatments were investigated. The system which were prepared with TLDs, RW3 solid water phantom and bolus are irradiated with 6-18 MeV energy x-rays (photon) at 0.2 Gy, 1 Gy and 5 Gy radiation doses by used a linear accelerator. Before irradiation, heat treatment, irradiation, post-irradiation heat treatment (pre-heat) and luminescence measurement (reading) were applied five times, element correction (ECC) and reader calibration factor (RCF) coefficients were determined for each dosimeter. Using these data, thermoluminescence (TL) intensities corresponding to irradiations were calculated. According to the results, it was determined that TLD-100, TLD-200 and TLD-400 dosimeters showed linear behavior in 0.2 Gy, 1 Gy and 5 Gy dose ranges. When the TL intensity data obtained as a result of the irradiations made with 6-18 MeV energy x-rays at three different radiation dose values are compared as TL6MeV / TL18MeV, it is seen that the rates change in the TLD-100 dosimeter. However, its seen that the TL6MeV / TL18MeV ratios did not change in the TLD-200 and TLD-400 dosimeters. From this, it is understood that TLD-100 dosimeter has energy dependence and TLD-200 and TLD-400 dosimeters do not have energy dependence. Besides, the TLD-200 dosimeter was determined to be approximately 40 times more sensitive than TLD-100 and approximately 8 times more sensitive than TLD-400. Finally, when the energy from 6 MeV to 18 MeV was changed, it was observed that TLD-200 / TLD-100 combination gave the highest sensitivity and TLD-400 / TLD-200 combination the lowest sensitivity.

Benzer Tezler

  1. Göz brakiterapisinde kullanılan 142Pr radyoizotopunun üretilmesi ve Monte Carlo yöntemiyle doz değerlendirmesi

    Production of 142Pr radioisotope and its dose evaluation by Monte Carlo method in eye brachytherapy applications

    NESLİHAN KOYUNCU

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Nükleer Mühendislikİstanbul Teknik Üniversitesi

    Nükleer Araştırmalar Ana Bilim Dalı

    PROF. DR. İSKENDER ATİLLA REYHANCAN

  2. Konik ışınlı bilgisayarlı tomografi kullanılarak dental implant bölgelerinin cerrahi öncesi değerlendirilmesi

    Pre-surgical assessment of dental implant sites by using cone beam computed tomography

    BİLGE CAN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2019

    Diş HekimliğiNecmettin Erbakan Üniversitesi

    Periodontoloji Ana Bilim Dalı

    DOÇ. DR. ELİF ÖNCÜ

  3. Akciğer kanserinde stereotaktik vücut radyoterapisi tedavilerinde radyal penumbra gözetimi yöntemi kullanılarak farklı tedavi tekniklerinin karşılaştırılması

    Comparison of different treatment techniques using deformed margin drawing method in stereotactic body radiotherapy treatments in lung cancer

    MELEK DEMİR

    Yüksek Lisans

    Türkçe

    Türkçe

    2017

    OnkolojiAcıbadem Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    DOÇ. DR. BANU ATALAR

  4. Kemoradyoterapi alan mide kanserli hastalarda CD133 ve Kİ-67'nin prognostik önemi

    Prognostic significance of CD133 and Ki-67 in the stomach cancer of patient treated with chemoradiotherapy

    İREM SARICANBAZ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2011

    OnkolojiGazi Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF. DR. ERAY KARAHACIOĞLU

  5. Erişkin glial tümör hastalarında prognozu etkileyen epidemiyolojik ve moleküler belirteçlerin izlenmesi: Prospektif-retrospektif tez çalışması

    Monitoring epidemiological and molecular markers affecting prognosis in adult glial tumor patients: A prospective-retrospective thesis study

    EYÜP BAYATLI

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2020

    NöroşirürjiAnkara Üniversitesi

    Nöroşirürji Ana Bilim Dalı

    PROF. DR. HASAN ÇAĞLAR UĞUR