Geri Dön

Anjiyografi ve girişimsel radyoloji ünitesinde çalışan personelin radyasyon maruziyeti

Radiation exposure of personnel working in angiography and interventional radiology unit

  1. Tez No: 574262
  2. Yazar: CEMİLE AVCI AKAN
  3. Danışmanlar: PROF. DR. HASAN GÜMÜŞ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Physics and Physics Engineering
  6. Anahtar Kelimeler: Radyasyon, Radyasyon etkileri, Radyoloji-girişimsel, X ışını, Radiation, Radiation effects, Radiology-interventional, X ray
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Ondokuz Mayıs Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Fizik Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Girişimsel radyoloji incelemeleri doz ölçümü yönünden son derece karmaşıktır. Kullanılan projeksiyon, diğer bir deyişle hastanın ışınlanan bölgesi sürekli değişir; ayrıca hasta yatağının ve görüntü güçlendiricinin hareketleri nedeniyle ışınlama geometrisinin değişimi önemli diğer bir faktördür. Işınlama sürekli (floroskopik) veya birbirini takip eden statik görüntüler şeklinde elde edilir. Bu ışınlamalarda sistemin kVp, mA ve ışınlama süresi hasta kalınlığına bağlı olarak sürekli değişir. Bu çalışmada amacımız Ondokuz Mayıs Üniversitesi Tıp Fakültesi Radyoloji Anabilim Dalı çalışanlarının ve hastaların radyoloji incelemelerinde maruz kaldıkları radyasyon dozu OSL dozimetreler kullanılarak belirlenmiştir. Yapılan çalışmada girişimsel radyoloji ünitesinde toplam üç hekimi iki radyoteknolog ve 129 hastanın doz değerleri belirlenmeye çalışılmıştır. Çalışanların radyasyon dozlarını değerlendirmek üzere altı aylık süre içinde OSL dozimetreleri ile radyasyon dozlarının ölçümü yapılmıştır. Hastaların işlem sırasındaki dozları ayrı ayrı ölçülmüştür. Hekimler için göğüs (yaka), cilt (kemer) ve bilek olmak üzere iki aylık toplam doz miktarları OSL dozimetreleri yardımıyla ölçüm alınmıştır. Aynı şekilde radyoteknologların göğüs (yaka) ve cilt (kemer) olmak üzere iki aylık toplam doz miktarları ölçülmüştür. Radyolojik girişimlerde floroskopi süresinin tanısal anjiyografilere göre birkaç misli olduğu ve dolayısıyla hasta ve radyoloğun çok daha fazla radyasyona maruz kaldığı görülmüştür. Maruz kalınan radyasyon dozu, hem floroskopi de hem de çekimlerde saniyedeki kare (frame) sayısı azaltılarak önemli miktarda azaltılabilir.

Özet (Çeviri)

Interventional radiology examinations are extremely complex in terms of dose measurement. The projection used, that is, the irradiated region of the patient, changes continuously; further, the variation of the irradiation geometry due to the movements of the patient bed and image amplifier is another important factor. Irradiation is obtained as continuous (fluoroscopic) or sequential static images. In these irradiations the kVp, mA and irradiation time of the system change continuously depending on the patient thickness. The aim of this study was to determine the radiation dose of Ondokuz Mayıs University Faculty of Medicine Department of Radiology by using OSL dosimeters. In this study, it was tried to determine the dose values of three physicians, two radiotechnologists and 129 patients in interventional radiology unit. In order to evaluate the radiation doses of the employees, radiation doses were measured with OSL dosimeters over a period of six months. The doses of the patients during the procedure were measured separately. OSL dosimeters were used to measure the total dose for two months: chest (collar), skin (belt) and wrist. In the same way, the total dose amounts of radiotechnologists for two months, chest (collar) and skin (belt) were measured. The duration of fluoroscopy in radiological interventions was several times higher than that of diagnostic angiography, and therefore the patient and radiologist were exposed to more radiation. The exposure radiation dose can be significantly reduced by reducing the number of frames per second during both fluoroscopy and shots.

Benzer Tezler

  1. Böbrek anjiyomiyolipomlarının endovasküler tedavisi: Orta ve uzun dönem sonuçları

    Endovascular treatment of renal angiomyolipomas: Mid-term and long-term results

    JAVID AHMADOV

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2018

    Radyoloji ve Nükleer TıpHacettepe Üniversitesi

    Radyoloji Ana Bilim Dalı

    PROF. DR. BORA PEYNİRCİOĞLU

  2. Karotis arter stenozlarında endovasküler tedavi etkinliğinin belirlenmesi

    Determination of carotid artery endovascular treatment effects in carotid artery stenosis

    PELİN ZEYNEP BEKİN SARIKAYA

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2014

    Radyoloji ve Nükleer TıpBaşkent Üniversitesi

    Dahili Tıp Bilimleri Bölümü

    YRD. DOÇ. DR. ALİ HARMAN

  3. Anevrizma kesesinde ve parent arterde peroperatif basınç ölçümlerinin kanamış ve kanamamış hastalarda karşılaştırılması

    The comparison of perioperative pressure measurements in intra-aneurysmal and parent artery in ruptured and unruptured aneuryms

    SEDA KANBAĞLI

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2013

    Radyoloji ve Nükleer TıpDokuz Eylül Üniversitesi

    Radyoloji Ana Bilim Dalı

    PROF. DR. SÜLEYMAN MEN

  4. İntrakraniyal anevrizmaların endovasküler tedavisinde akım çevirici silk stent kullanımının etkinlik ve güvenilirliliği

    Efficacy and safety of use of flow diverting silk stent in endovascular treatment of intracranial aneurysms

    ESHGIN SAHIBLI

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2022

    Radyoloji ve Nükleer Tıpİstanbul Üniversitesi

    Radyoloji Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ MEHMET BARBUROĞLU

  5. Pediatrik hastalara yerleştirilen portların takip sonuçlarının değerlendirilmesi

    Evaluation of the follow-up results of pediatric central venous ports

    ÇİĞDEM SAMUR SALBAŞ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2013

    Radyoloji ve Nükleer TıpNecmettin Erbakan Üniversitesi

    Radyoloji Ana Bilim Dalı

    DOÇ. DR. OSMAN KOÇ