Geri Dön

Güncel NiTi döner eğe sistemleri ile kök kanalı şekillendirilmesi sırasında farklı çalışma uzunluklarınin dentinde çatlak oluşumuna etkisinin araştırılması

Investigation of the effects of different working lengths on crack formation during the root canal preparation with current NiTi rotary file systems

  1. Tez No: 567063
  2. Yazar: MÜNİP ÇOLAKOĞLU
  3. Danışmanlar: PROF. DR. RAİF ERİŞEN
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Farklı çalışma uzunlukları, Dentin çatlağı, NiTi döner eğe sistemleri, Dental aygıtlar, Dental pulpa boşluğu, Dental sızma, Dentin, Kök kanal tedavisi, Mikroçatlaklar, Dentinal cracks, NiTi rotary systems, different working lengths, Dental instruments, Dental pulp cavity, Dental leakage, Dentin, Root canal therapy, Microfissuring
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Endodonti Ana Bilim Dalı
  12. Bilim Dalı: Endodonti Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmada, farklı geometrik şekillere, farklı koniklik açılarına ve farklı metaralojik özelliklere sahip güncel olarak kullanılan ProTaper Next (Dentsply, Maillefer, Ballagues, İsviçre), Mtwo (VDW, Munich, Germany), Hyflex CM (Coltene, Allstatten, Switzerland) NiTi döner eğe sistemleri ve Mani Flare NiTi el eğesi (Mani Inc., Tochigi Japan) ile farklı çalışma uzunluklarında çalışıldıklarında dentin üzerinde oluşturdukları çatlaklar gözlemlenmiştir. Çalışmamızın amacı bu değişkenliklerin dentin üzerinde oluşan çatlaklara etkisini gözlemlemektir. Çalışmamızda 260 adet çekilmiş alt çene kesici insan dişi kullanılmıştır. Dişler 12 deney grubu (n:20) ve 2 kontrol grubuna (n:10) rastgele seçilmiştir. Dişlerin kök kanallarının şekillendirilmesi seçilen NiTi döner eğe sistemleri ve NiTi el eğeleri ile 3 farklı çalışma uzunluğunda apikal genişlik 0,30 mm olacak şekilde tamamlanmıştır. Şekillendirme yapılan dişlerden su soğutması altında düşük hızlı testere ile kesitler alındı. Alınan kesitler ve dişlerin apikal yüzeyleri çatlak tespiti için steromikroskop ile incelendi. Çalışma uzunluları değerlendirildiğinde istatiksel olarak anlamlı fark bulunmamasına rağmen AF+1 gruplarında AF ve AF-1 gruplarına göre daha çok çatlak gözlemlenmiştir. Eğe sistemleri değerlendirildiğinde istatiksel olarak anlamlı fark olmamasına rağmen en çok çatlak MT gurubunda (kesitlerde %10,6 apikal yüzeyde %8,3) gözlemlenmiştir. Bunu sırasıyla PTN (kesitlerde %5,6, apikal yüzeyde %5), HF (kesitlerde %3,9 , Apikal yüzeyde %1,7) , Mani Flare NiTi el (kesitlerde %1,1 , apikal yüzeyde %1,7) grupları izlemiştir. Çalışmamızın sonucunda elde edilen bulgular doğrultusunda NiTi döner eğe sistemleri ile apikal foramenden 1 mm kısa şekillendirme yapmanın ve apikal son 1 mm'de şekillendirme yapılırken NiTi el eğelerinin veya geleneksel olmayan NiTi döner eğe sistemlerinin tercih edilmesinin çatlak oluşumunda en güvenilir yöntem olduğu gözlenmiştir.

Özet (Çeviri)

In our study, we observed cracks on the dentin when the root canals were instrumented at different working lengths with ProTaper Next (Dentsply, Maillefer, Ballagues, İsviçre), Mtwo (VDW, Munich, Germany), Hyflex CM (Coltene, Allstatten, Switzerland) NiTi rotary files and Mani Flare NiTi hand files (Mani Inc., Tochigi Japan) which have different geometric shapes, different tapers and different metarological features. The aim of our study was to observe the effects of these variations on the cracks on the dentin. In our study, 260 extracted human mandibular incisor teeth were used. The teeth were randomly selected in 12 experimental groups (n: 20) and 2 control groups (n: 10). Preparation of the root canals of the teeth has been completed with NiTi rotary systems and NiTi hand files with apical width of 0.30 mm at 3 different working lengths. The roots were sectioned horizontally at 3, 6 and 9 mm from the apex. Taken sections and apical surfaces of teeth were examined by a stereomicroscope for crack detection. Although there was no statistically significant difference when the study lengths were evaluated, more cracks were observed in AF + 1 groups than AF and AF-1 groups. Although no statistically significant difference was observed when NiTi systems were evaluated, it was observed that the most cracks were in the MT group (10.6% in the sections, 8,3 %the apical surface). PTN (5.6% in sections, 5% in apical surface), HF (3.9% in sections, 1.7% in Apical surface), Mani Flare NiTi hand file(1.1% in sections, 1.7% in apical surface) were followed respectively. As a result of our study, It is observed that preparate with NiTi rotary file systems, at 1 mm short from the apical foramen and when preparate apical end 1 mm, using NiTi hand files or non-traditional NiTi rotary file systems are the most reliable method for crack formation.

Benzer Tezler

  1. Güncel tek eğe sistemleri ile kök kanalı şekillendirilmesi öncesi rehber yol hazırlanmasının şekillendirme sırasında dentinde defekt oluşumuna etkisinin araştırılması

    Effect of dentinal defect formation during preparation of glide paths before root canal shaping by current single file systems

    MUAMMER KIVANÇ AKSOY

    Doktora

    Türkçe

    Türkçe

    2018

    Diş Hekimliğiİstanbul Üniversitesi

    Endodonti Ana Bilim Dalı

    PROF. DR. SEÇKİN DİNDAR

  2. Türkiye'de endodontistler tarafından endodontik tedavide tercih edilen materyal, yöntem ve tedavi protokolünün belirlenmesi

    Survey of materials, attitudes and treatment methods preferred in root canal therapy by endodontists in turkey

    SERPİYE MERVE GÖRÜR

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2019

    Diş HekimliğiEge Üniversitesi

    Endodonti Ana Bilim Dalı

    PROF. DR. NECDET ERDİLEK

  3. Adolesan intihar girişimlerinin psiko-sosyal nedenleriyle ilgili araştırma

    Başlık çevirisi yok

    NAZMİYE YÜKSEL

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Psikolojiİstanbul Üniversitesi

    Aile Sağlığı Ana Bilim Dalı

    DOÇ. DR. AYSEL EKŞİ

  4. Geleneksel Sivrihisar evleri

    Traditional houses of Sivrihisar

    FİSUN ÖZŞUÇA

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    MimarlıkGazi Üniversitesi

    Mimarlık Ana Bilim Dalı

    YRD. DOÇ. DR. ORHAN CEZMİ TUNCER

  5. He-Ne laserinin yapımı

    Başlık çevirisi yok

    AKİF ÖZBAY

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Fizik ve Fizik MühendisliğiGazi Üniversitesi

    Fizik Ana Bilim Dalı

    DOÇ. DR. ATİLLA ÖZMEN