Farklı yerleştirme açısının ve sterilizasyon sonrası yeniden kullanımın titanyum ve paslanmaz çelik minividaların primer stabiliteleri üzerine etkilerinin incelenmesi

Evaluation of the effects of different placement angles and reusage after sterilization process on the primer stabilities of tianium and stainless stell miniscrews

  1. Tez No: 559364
  2. Yazar: AYŞE KARKAÇ
  3. Danışmanlar: DR. ÖĞR. ÜYESİ NİSA GÜL AMUK
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: ortodontik minivida, primer stabilite, rezonans frekans analizi, paslanmaz çelik, titanyum alaşım, yeniden kullanım, Frekans analizi, Kemik vidaları, Ortodonti, Ortodontik aygıtlar, Rezonans, Titanyum, Yeniden kullanma, orthodontic miniscrews, primary stability, resonance frequency analysis, stainless steel, titanium alloys, reusage, Frequency analysis, Bone screws, Orthodontics, Orthodontic appliances, Resonance, Titanium, Reuse
  7. Yıl: 2018
  8. Dil: Türkçe
  9. Üniversite: Erciyes Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı, 60° ve 90° açılarda yerleştirilmiş paslanmaz çelik ve titanyum minividaların, ilk kullanım ve sterilizasyon döngüsü sonrası yeniden kullanımının primer stabilite, yerleştirme torku ve çıkarma torku açısından değerlendirmek ve karşılaştırmaktır. Çalışmamızda self-drilling özelliğe sahip 50 adet paslanmaz çelik, 50 adet titanyum minivida kullanılmıştır. Minividalar sığır kalça kemiğinden elde edilen kemik bloklarına uygulanmıştır. Minivida yerleştirilecek olan kortikal kemik alanlarının belirlenmesi amacıyla kemik blokları bilgisayarlı tomografi ile incelenmiştir. Uygulama noktalarındaki kortikal kemik kalınlığı 1 ile 1,8 mm arasında olan kemik blokları seçilerek minividalar yerleştirilmiştir. Gruplar paslanmaz çelik ve titanyum alaşımdan oluşan minividaların 60 ve 90 açıda, ilk kullanım ve recycled kullanımındaki primer stabilitelerinin inceleneceği 8 farklı gruptan oluşmaktadır. Primer stabilite, immediat kuvvet uygulamadan önce yapılan ilk ölçüm ve kuvvet uygulandıktan sonra yapılan ölçümler olarak farklı zaman aralıklarında değerlendirilmiştir. Minivida yerleştirilirken yerleştirme torku, 24 saat sonra yapılan son rezonans frekans analizi (RFA) ölçümünden sonra da çıkarma torku değerleri ölçülmüştür. Gruplar karşılaştırıldığında, RFA ve tork değerlerine göre minividaların açıdan bağımsız olarak materyale göre ilk kullanımda primer stabilitelerinde anlamlı bir fark bulunmamıştır. Minividaların recycled kullanımında açıdan bağımsız olarak materyale göre primer stabilite karşılaştırmasında paslanmaz çelik materyalin hem RFA hem de tork değerleri daha yüksek bulunmuştur (p<0.001). 60'de yerleştirilen paslanmaz çelik ve titanyum alaşımdan üretilmiş mininividaların primer stabiliteleri arasında hem recycled hem de ilk kullanımda RFA ve yerleştirme tork ölçümü sonuçlarına göre anlamlı fark bulunmamaktadır. 90 açıda yerleştirilen titanyum ve paslanmaz çelik alaşımdan üretilen minividaların primer stabilitesinde RFA ve tork değerlerinde anlamlı fark bulunmuştur (p<0.001). Sonuç olarak, minividaların ilk kullanımında paslanmaz çelik ve titanyum minividalar benzer primer stabilite gösteririrken, recycled kullanımda paslanmaz çelik materyal titanyumdan daha üstündür. Minividaların 90 açıda uygulamasında paslanmaz çelik materyal daha iyi primer stabilite sağlamıştır.

Özet (Çeviri)

The aim of this in-vitro study was to evaluate the primary stability of stainless steel and titanium miniscrews placement at 60° and 90° angles, at the first use and re-use after sterilization cycle using measurements of placement torque, removal torque and resonance frequency analysis (RFA). In this study, 50 stainless steel and 50 titanium miniscrews were inserted to bone blocks prepared from ilium of bovine via self-drilling procedure. Bone blocks were examined by computed tomography to determine the cortical bone thickness at the miniscrew placement areas. Bone blocks which had cortical bone thickness between 1 and 1.8 mm were selected at the points where the miniscrews were applied. The study was composed of 8 different groups for evaluation of the primary stability of the stainless steel and titanium miniscrews inserted with 60 and 90 angle at the first and recycled use. The primary stability evaluation was performed by measurements the resonance frequency analysis (RFA) at the immediate force application period and at different time intervals after the force application. Insertion torque was measured at the time of miniscrew placement and the removal torque values were measured after 24 hours. When the groups were compared, there was no significant difference at the primary stability with respect to the material in the first use of the miniscrews according to RFA and torque values. In the comparison of the primary stability of recycled stainless steel and titanium miniscrews, both the RFA and torque values of stainless steel material were higher than titanium (p<0.001). There was no significant difference between the primary stability of the miniscrews made of stainless steel and titanium placed at 60, both in the recycled and in the first use, according to the results of RFA and placement torque measurement. Significant difference was found between the primary stability of the miniscrews made of titanium and stainless steel alloy placed at 90° angle (p<0.001). As the conclusion, in the first use of the miniscrews, stainless steel and titanium miniscrews showed similar primary stability, whereas in recycled use, stainless steel material was superior to titanium. The stainless steel material provided higher primary stability in the 90° angle placement of the miniscrews.

Benzer Tezler

  1. Farklı yöntemler ile imal edilen minividalarda üretim materyalinin, yerleştirme açısının ve sterilizasyon sonrası yeniden kullanımın primer stabilite üzerine etkilerinin karşılaştırılması

    Comparison of the effects of manufacturing material, insertion angle and post-sterilization reuse on primary stability in miniscrews manufactured by different methods

    MERİÇ ÖZTÜRK YAŞAR

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2023

    Diş HekimliğiErciyes Üniversitesi

    Ortodonti Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ CELAL IRGIN

  2. Dört farklı ortodontik mini vidanın yerleştirme torku ve stabilite değerlerinin karşılaştırılması

    The comparison of insertion torque and stability values of four different orthodontic mini-screws

    MOHAMMED ABDO MOHAMMMED AL-RAAWI

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2017

    Diş HekimliğiÇukurova Üniversitesi

    Ortodonti Ana Bilim Dalı

    PROF. DR. MUSTAFA SERDAR TOROĞLU

  3. Atrofik tam dişsiz maksillada farklı açı ve çaplarda yerleştirilmiş pterygoid implantlar üzerine uygulanan hibrit protezlerin sonlu elemanlar stres analiz yöntemi ile incelenmesi

    Investigation of hybrid prostheses prepared on pterygoid implants placed at different angles and diameters in atrophic total edentulous maxilla by finite element stress analysis method

    FATİH OKTAY

    Doktora

    Türkçe

    Türkçe

    2024

    Diş HekimliğiAtatürk Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. FUNDA BAYINDIR

  4. Geogrid donatılı istinat duvarı tasarımında ön yüz eğim açısının geogridlerin kopmaya ve sıyrılmaya karşı güvenlik katsayıları üzerindeki etkisinin araştırılması

    Investigation of the effect of the face batter angle on the factors of safety against both rupture and pullout of the geogrids in the geogrid reinforced retaining wall design

    SERAY GÜL BERSU ÖZEL

    Yüksek Lisans

    Türkçe

    Türkçe

    2025

    İnşaat MühendisliğiGazi Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    PROF. DR. MUSTAFA ÖZER

  5. Eksenel akılı sürekli mıknatıslı generatörlerde mıknatıs açısı ve gruplama tekniğinin vuruntu momenti üzerine etkisi

    The effect of magnetic angle and grouping technique on cogging torque in axial flux permanent magnet generators

    AYKAN MUTLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2020

    Elektrik ve Elektronik MühendisliğiKırklareli Üniversitesi

    Enerji Sistemleri Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ ENGİN HÜNER