Geri Dön

Miyopik olgularda maküla fonksiyonun anatomik ve elektrofizyolojik olarak değerlendirilmesi

Anatomical and electrophysiological evaluation of macular function in myopic patients

  1. Tez No: 539615
  2. Yazar: YAĞMUR DENİZ
  3. Danışmanlar: PROF. DR. GÜLİZ FATMA YAVAŞ
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Göz Hastalıkları, Eye Diseases
  6. Anahtar Kelimeler: Spektral Domain Optik Koherens Tomografi, pattern elektrografi, miyopi, Anatomi, Elektrofizyoloji, Elektroretinografi, Göz hastalıkları, Makula lutea, Tomografi-optik koherens, Spectral Domain Optical Coherence Tomography, pattern electrography, myopia, Anatomy, Electrophysiology, Electroretinography, Eye diseases, Macula lutea, Tomography-optical coherence
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Hacettepe Üniversitesi
  10. Enstitü: Tıp Fakültesi
  11. Ana Bilim Dalı: Göz Hastalıkları Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı; miyopik olgularda arka segment parametrelerini değerlendirerek makülanın anatomik yapısını spektral domain optik koherens tomografi (SDOKT) ile ve fonksiyonel açıdan pattern elektroretinografi (PERG) ile incelenmek ve aralarındaki korelasyonu saptamaktır. Çalışma grubu 78'i kadın, 40'ı erkek toplam 118 olgudan oluşturuldu. Kırma kusuru derecesine göre olgular 4 gruba ayrıldı. Birinci grup 0.00/-0.75 D arası (kontrol grubu), ikinci grup -1.00/-2.75 D arası, üçüncü grup -3.00/-5.75 D arası, dördüncü grup -6.00 D ve üstü olarak belirlendi. Tüm olgularda peripapiller RSLT kalınlığı, maküla kalınlığı, retina katlarının kalınlığı ve koroid kalınlığı SDOKT kullanılarak ölçüldü ve ardından PERG testi uygulandı. Miyopi derecesi artışı ile T kadran hariç RSLT kalınlığında azalma olduğu gözlendi. Maküler kalınlık ve retina katlarının (dış pleksiform tabaka hariç) kalınlıkları ile miyopi derecesi arasında bir ilişki bulunamadı. Yüksek miyopi grubunda maküler kalınlık ile N95 amplitüdü arasında negatif korelasyon saptandı. Miyopi derecesi ve AU artışı ile subfoveal koroid kalınlığı azalmaktaydı. AU ile subfoveal koroidal kalınlık arasında negatif korelasyon olduğu görüldü. P50 ve N95 dalgalarının amplitüdlerinde yüksek miyopi grubu ile kontrol grubu arasında istatiksel olarak anlamlı fark olduğu bulundu. Miyopi derecesinin artması ile ilişkili olarak P50 ve N95 amplitüdündeki azalma belirginleşiyordu. N95 amplitüdündeki azalma aksiyel uzunluk artışı ile korelasyon göstermekteydi. Maküler retina katlarında anatomik bir değişiklik olmadan ve EİDGK etkilenmemiş iken P50 amplitüdünde azalma olması, fonksiyonel açıdan makülanın yüksek miyop olgularda etkilenebileceğini düşündürmektedir. N95 amplitüdündeki azalmanın ise AU'daki artış ve global peripapiller RSLT kalınlığındaki azalma ile ilişkili olabileceği düşünüldü.

Özet (Çeviri)

The aim of this study is to evaluate the posterior segment parameters, the anatomical structure of macula with Spectral Domain Optic Coherence Tomography (SD-OCT) and electrophysiological function of the macula with pattern electroretinography (PERG) in myopic cases and to determine the correlation between them. The study group included 118 subjects (78 female, 40 male). Cases were divided into four groups according to the degree of refractive errors. The first group was between 0.00 / -0.75 D (control group), the second group between -1.00/ -2.75 D, the third group between -3.00 / -5.75 D and the fourth group as -6.00 D and higher. Peripapillary RNFL thickness, macular thickness, thickness of the retinal layers and choroidal thickness were measured using SD-OCT in all cases and then PERG test was applied. It was found that there was a decrease in RNFL thickness except T quadrant with the increase in degree of myopia. There was no correlation between macular thickness and the thickness of retinal layers (except the outer plexiform layer) and the degree of myopia. Negative correlation was found between macular thickness and N95 amplitude in high myopia group. It was found that subfoveal choroidal thickness decreased with increased degree of myopia and increase in AL. There was a negative correlation between AL and subfoveal choroidal thickness. There was a statistically significant difference between the high myopia group and the control group in the amplitudes of P50 and N95 waves. The decrease in P50 and N95 amplitude was observed to be associated with the increase in the degree of myopia. The decrease in N95 amplitude correlated with the increase in axial length. The decrease in P50 amplitude without an anatomical change in macular retinal layers and without reduction of BCVA is suggestive that macula can be affected in high myopia cases in terms of function. The decrease in N95 amplitude was thought to be related with increase in AL and decrease in global peripapillary RNFL thickness.

Benzer Tezler

  1. Down sendromu olgularında göz bulguları

    Başlık çevirisi yok

    ZUHAL SUYUGÜL

    Doktora

    Türkçe

    Türkçe

    1990

    Göz Hastalıklarıİstanbul Üniversitesi

    PROF.DR. ASIM CENANİ

  2. Tomografi ile saptanan talamik hemorajilerde klinik bulguların analizi

    Başlık çevirisi yok

    VEYSİ ÖZKILIÇ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1991

    NörolojiDicle Üniversitesi

    Nöroloji Ana Bilim Dalı

  3. Katarakt cerrahisinde rijid pupilla ve radyal iridotomi

    Başlık çevirisi yok

    FARUK DEMİRTAŞ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1993

    Göz HastalıklarıSağlık Bakanlığı

    DR. SUNAY DUMAN

  4. Anizometropik ambliopide klinik özellikler

    Başlık çevirisi yok

    SUPHİ ALOLO

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1993

    Göz Hastalıklarıİstanbul Üniversitesi

    Göz Hastalıkları Ana Bilim Dalı