Geri Dön

Farklı yaşlandırma tekniklerinin farklı kalınlıktaki tam seramik materyallerin renk değişimi üzerine etkisinin incelenmesi

Investigation of the effect of different aging techniques on the color change of full ceramic materials at different thicknesses

  1. Tez No: 534202
  2. Yazar: TUĞBA TEMİZCİ
  3. Danışmanlar: PROF. DR. ALİ RIZA TUNÇDEMİR
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Renk değişimi, Tam seramikler, Yaşlandırma, Dental materyaller, Dental porselen, Diş renk değişikliği, Takma diş-tam, Aging, All-ceramics, Color differences, Dental materials, Dental porcelain, Tooth discoloration, Denture complete, Ageing
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Necmettin Erbakan Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Çalışmanın amacı; üç farklı yaşlandırma yönteminin, iki farklı kalınlıkta hazırlanan üç farklı tam seramik sistemindeki renk değişimi üzerine etkilerini incelemektir. 0.5 ve 1.0 mm'lik kalınlıklarda hazırlanan Zirkonya Katana UTML (ZK), Prettau Anterior (PA) ve IPS-emax pres (EP) tam seramik materyallerine in vitro hızlandırılmış yaşlandırma (AAA) (Atlas Xenontest Alpha high energy weather device, Chicago, USA) ISO 7491, termal siklus (TC) (SD Mechatronik Thermocycler) ISO TR 11450 ve otoklavda yaşlandırma (AA) (Melag Vacuklav 23B+, Berlin, Almanya) ISO 6474-2 standard protokolleriyle yaklaşık 1 yıllık yaşlandırma uygulanmıştır. Test edilen yaşlandırma yöntemlerinin tam seramik örneklerinin renk [(Commission Internationale d'Eclairage) CIE L*a*b*)] değişimlerine (∆E) etkileri spektrofotometre (Lovibond RT Series Reflectance Tintometer UK) ile ölçülmüş, varyans analizi (ANOVA) ile değerlendirilmiştir. Çalışmamızda kullanılan her üç yaşlandırma yöntemi de tam seramik örneklerinde önemli renk değişimine neden olmuştur. Yaşlandırma yöntemleri (AAA, TC ve AA) seramik sistemlerinin ΔE değerlerini farklı düzeylerde (0.86-3.60 aralığında) etkilemiştir. En büyük ∆E değeri 0.5 mm kalınlıkta hazırlanan TC testi uygulanan EP seramik sisteminde (3.60) belirlenmiştir. 0.5 mm lik EP grubunu harici tutup bir genelleme yapacak olursak yaşlandırma yöntemleri arasında en fazla renk değişimi gösteren yöntem hızlandırılmış yaşlandırma, sonra termal siklus en sonda otoklavda yaşlandırma uygulaması olmuştur. Seramik kalınlıklarının ΔE değerlerine etkileri her üç yaşlandırma yönteminde de önemli bulunmuştur. Yaşlandırma uygulamaları ile oluşan ∆E değerlerinin çok yönlü varyans analizi sonuçlarına göre yaşlandırma yöntemleri, seramik kalınlıkları ve seramik sistemleri birlikte değerlendirildiğinde istatistiki olarak önemli bulunmuştur. PA seramik sistemine AAA testi uygulananları dışında, tüm seramik örneklerinde, seramik kalınlığı arttıkça mutlak değer olarak ∆E değerlerinin azaldığı belirlenmiştir. Test edilen seramik materyallerin genelinde ∆E değerleri klinik olarak algılanabilir düzeyin altında kalmıştır (∆E <3.5). Sonuç olarak, tam seramik örneklerinde in vitro yaşlandırma uygulamalarıyla renk değişimleri karşılaştırılırken uygulanacak yaşlandırma protokolü, seramik tipi ve seramik kalınlığı birlikte değerlendirilmelidir.

Özet (Çeviri)

The aim of the study is to investigate the effects of three different aging methods on color change in three different full ceramic systems prepared in two different thicknesses. Zirconia Katana UTML (ZK), Prettau Anterior (PA) and IPS-emax press (EP) prepared in 0.5 and 1.0 mm thickness were tested by in vitro accelerated aging (AAA) (Atlas Xenontest Alpha high energy weather device, Chicago) ISO 7491, thermocycling, (TC) (SD Mechatronic Thermocycler) ISO TR 11450 and autoclave aging (AA) (Melag Vacuklav 23B +, Berlin, Germany) ISO 6474-2 standard protocols. The effects on the color (CIE L* a* b*)] changes (∆E) were determined by spectrophotometer (Lovibond RT Series Reflectance Tintometer UK) of all-ceramic samples of the tested aging methods and evaluated by analysis of variance (ANOVA). All three aging methods used in our study also resulted in significant color difference in full ceramic samples. Aging methods (AAA, TC and AA) affected the ∆E values of ceramic systems at different levels (in the range 0.86-3.60). The largest ∆E value was prepared in 0.5 mm thickness and was determined in EP ceramic system (3.60) with TC test. If a generalization is made excluding the 0.5 mm EP group, among the methods of aging, the most color change method was accelerated aging, then the thermal cycling was finally autoclave aging. The effects of ceramic thickness on ∆E values were found to be significant in all three aging methods. According to the results of multivariate analysis of variance of ∆E values formed by aging applications, aging methods, ceramic thickness and ceramic systems were found statistically significant. In addition to the AAA test applied to PA ceramic system, it was determined that ∆E values decreased in absolute value as the ceramic thickness increased in all ceramic samples. In general, the ∆E values of the ceramic materials tested were below the clinically detectable level (∆E <3.5). As a result, aging protocol, ceramic type and ceramic thickness should be evaluated together when comparing color changes with in vitro aging applications in full ceramic samples.

Benzer Tezler

  1. Investigation of the effect of heat treatments on the formability of the 6061 Al alloy

    Isıl işlemlerin 6061 Al alaşımının şekillendirilebilirliğineetkisinin incelenmesi

    RAŞİD AHMED YILDIZ

    Doktora

    İngilizce

    İngilizce

    2019

    Makine Mühendisliğiİstanbul Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. ŞAFAK YILMAZ

  2. Farklı üretim teknikleri ile hazırlanmış co-cr metal altyapıların dental porselen ile bağlanma dayanımlarının yaşlandırma işlemi sonrası incelenmesi

    Evaluation of the bond strengths of co-cr metal frameworks prepared using by different manufacturing methods with dental porcelain after thermal aging process

    ELİF ECE ÜZEL

    Doktora

    Türkçe

    Türkçe

    2018

    Diş HekimliğiAkdeniz Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. ULVİYE ŞEBNEM BÜYÜKKAPLAN

  3. Yerli imalat yumuşak metal blok kullanılarak üretilen metal altyapıların seramik bağlanma ilişkisinin değerlendirilmesi ve farklı tekniklerle üretilen metal altyapılarla karşılaştırılması

    The evaluation of bond strength between dental ceramic and metal framewoks fabricated by using domestic manufactured soft metal block and comparing with different manufacturing techniques

    BETÜL KOÇAK KARAHAN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2020

    Diş HekimliğiErciyes Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. HASAN ÖNDER GÜMÜŞ

  4. A Low bit rate video coding algorithm

    Düşük bit hızlı video sıkıştırma algoritması

    GÜRDAL ÖRÜKLÜ

    Yüksek Lisans

    İngilizce

    İngilizce

    1998

    Elektrik ve Elektronik MühendisliğiBoğaziçi Üniversitesi

    Elektrik Mühendisliği Ana Bilim Dalı

    PROF. DR. AVNİ MORGÜL

  5. Farklı kompozisyonlardaki cad/cam bloklara uygulanan mekanik parlatma ve glaze işlemlerinin renklenme üzerindeki etkisinin değerlendirilmesi

    Evaluation of the effect of polishing and glaze techniques on the color stainability of cad/cam blocks with different microstructures

    DENİZ YILMAZ

    Doktora

    Türkçe

    Türkçe

    2017

    Diş HekimliğiAnkara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. LALE KARAAĞAÇLIOĞLU