Farklı yaşlandırma tekniklerinin farklı kalınlıktaki tam seramik materyallerin renk değişimi üzerine etkisinin incelenmesi
Investigation of the effect of different aging techniques on the color change of full ceramic materials at different thicknesses
- Tez No: 534202
- Danışmanlar: PROF. DR. ALİ RIZA TUNÇDEMİR
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Renk değişimi, Tam seramikler, Yaşlandırma, Dental materyaller, Dental porselen, Diş renk değişikliği, Takma diş-tam, Aging, All-ceramics, Color differences, Dental materials, Dental porcelain, Tooth discoloration, Denture complete, Ageing
- Yıl: 2019
- Dil: Türkçe
- Üniversite: Necmettin Erbakan Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Çalışmanın amacı; üç farklı yaşlandırma yönteminin, iki farklı kalınlıkta hazırlanan üç farklı tam seramik sistemindeki renk değişimi üzerine etkilerini incelemektir. 0.5 ve 1.0 mm'lik kalınlıklarda hazırlanan Zirkonya Katana UTML (ZK), Prettau Anterior (PA) ve IPS-emax pres (EP) tam seramik materyallerine in vitro hızlandırılmış yaşlandırma (AAA) (Atlas Xenontest Alpha high energy weather device, Chicago, USA) ISO 7491, termal siklus (TC) (SD Mechatronik Thermocycler) ISO TR 11450 ve otoklavda yaşlandırma (AA) (Melag Vacuklav 23B+, Berlin, Almanya) ISO 6474-2 standard protokolleriyle yaklaşık 1 yıllık yaşlandırma uygulanmıştır. Test edilen yaşlandırma yöntemlerinin tam seramik örneklerinin renk [(Commission Internationale d'Eclairage) CIE L*a*b*)] değişimlerine (∆E) etkileri spektrofotometre (Lovibond RT Series Reflectance Tintometer UK) ile ölçülmüş, varyans analizi (ANOVA) ile değerlendirilmiştir. Çalışmamızda kullanılan her üç yaşlandırma yöntemi de tam seramik örneklerinde önemli renk değişimine neden olmuştur. Yaşlandırma yöntemleri (AAA, TC ve AA) seramik sistemlerinin ΔE değerlerini farklı düzeylerde (0.86-3.60 aralığında) etkilemiştir. En büyük ∆E değeri 0.5 mm kalınlıkta hazırlanan TC testi uygulanan EP seramik sisteminde (3.60) belirlenmiştir. 0.5 mm lik EP grubunu harici tutup bir genelleme yapacak olursak yaşlandırma yöntemleri arasında en fazla renk değişimi gösteren yöntem hızlandırılmış yaşlandırma, sonra termal siklus en sonda otoklavda yaşlandırma uygulaması olmuştur. Seramik kalınlıklarının ΔE değerlerine etkileri her üç yaşlandırma yönteminde de önemli bulunmuştur. Yaşlandırma uygulamaları ile oluşan ∆E değerlerinin çok yönlü varyans analizi sonuçlarına göre yaşlandırma yöntemleri, seramik kalınlıkları ve seramik sistemleri birlikte değerlendirildiğinde istatistiki olarak önemli bulunmuştur. PA seramik sistemine AAA testi uygulananları dışında, tüm seramik örneklerinde, seramik kalınlığı arttıkça mutlak değer olarak ∆E değerlerinin azaldığı belirlenmiştir. Test edilen seramik materyallerin genelinde ∆E değerleri klinik olarak algılanabilir düzeyin altında kalmıştır (∆E <3.5). Sonuç olarak, tam seramik örneklerinde in vitro yaşlandırma uygulamalarıyla renk değişimleri karşılaştırılırken uygulanacak yaşlandırma protokolü, seramik tipi ve seramik kalınlığı birlikte değerlendirilmelidir.
Özet (Çeviri)
The aim of the study is to investigate the effects of three different aging methods on color change in three different full ceramic systems prepared in two different thicknesses. Zirconia Katana UTML (ZK), Prettau Anterior (PA) and IPS-emax press (EP) prepared in 0.5 and 1.0 mm thickness were tested by in vitro accelerated aging (AAA) (Atlas Xenontest Alpha high energy weather device, Chicago) ISO 7491, thermocycling, (TC) (SD Mechatronic Thermocycler) ISO TR 11450 and autoclave aging (AA) (Melag Vacuklav 23B +, Berlin, Germany) ISO 6474-2 standard protocols. The effects on the color (CIE L* a* b*)] changes (∆E) were determined by spectrophotometer (Lovibond RT Series Reflectance Tintometer UK) of all-ceramic samples of the tested aging methods and evaluated by analysis of variance (ANOVA). All three aging methods used in our study also resulted in significant color difference in full ceramic samples. Aging methods (AAA, TC and AA) affected the ∆E values of ceramic systems at different levels (in the range 0.86-3.60). The largest ∆E value was prepared in 0.5 mm thickness and was determined in EP ceramic system (3.60) with TC test. If a generalization is made excluding the 0.5 mm EP group, among the methods of aging, the most color change method was accelerated aging, then the thermal cycling was finally autoclave aging. The effects of ceramic thickness on ∆E values were found to be significant in all three aging methods. According to the results of multivariate analysis of variance of ∆E values formed by aging applications, aging methods, ceramic thickness and ceramic systems were found statistically significant. In addition to the AAA test applied to PA ceramic system, it was determined that ∆E values decreased in absolute value as the ceramic thickness increased in all ceramic samples. In general, the ∆E values of the ceramic materials tested were below the clinically detectable level (∆E <3.5). As a result, aging protocol, ceramic type and ceramic thickness should be evaluated together when comparing color changes with in vitro aging applications in full ceramic samples.
Benzer Tezler
- Investigation of the effect of heat treatments on the formability of the 6061 Al alloy
Isıl işlemlerin 6061 Al alaşımının şekillendirilebilirliğineetkisinin incelenmesi
RAŞİD AHMED YILDIZ
Doktora
İngilizce
2019
Makine Mühendisliğiİstanbul Teknik ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
PROF. DR. ŞAFAK YILMAZ
- Farklı üretim teknikleri ile hazırlanmış co-cr metal altyapıların dental porselen ile bağlanma dayanımlarının yaşlandırma işlemi sonrası incelenmesi
Evaluation of the bond strengths of co-cr metal frameworks prepared using by different manufacturing methods with dental porcelain after thermal aging process
ELİF ECE ÜZEL
Doktora
Türkçe
2018
Diş HekimliğiAkdeniz ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. ULVİYE ŞEBNEM BÜYÜKKAPLAN
- Yerli imalat yumuşak metal blok kullanılarak üretilen metal altyapıların seramik bağlanma ilişkisinin değerlendirilmesi ve farklı tekniklerle üretilen metal altyapılarla karşılaştırılması
The evaluation of bond strength between dental ceramic and metal framewoks fabricated by using domestic manufactured soft metal block and comparing with different manufacturing techniques
BETÜL KOÇAK KARAHAN
Diş Hekimliği Uzmanlık
Türkçe
2020
Diş HekimliğiErciyes ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. HASAN ÖNDER GÜMÜŞ
- A Low bit rate video coding algorithm
Düşük bit hızlı video sıkıştırma algoritması
GÜRDAL ÖRÜKLÜ
Yüksek Lisans
İngilizce
1998
Elektrik ve Elektronik MühendisliğiBoğaziçi ÜniversitesiElektrik Mühendisliği Ana Bilim Dalı
PROF. DR. AVNİ MORGÜL
- Farklı kompozisyonlardaki cad/cam bloklara uygulanan mekanik parlatma ve glaze işlemlerinin renklenme üzerindeki etkisinin değerlendirilmesi
Evaluation of the effect of polishing and glaze techniques on the color stainability of cad/cam blocks with different microstructures
DENİZ YILMAZ
Doktora
Türkçe
2017
Diş HekimliğiAnkara ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. LALE KARAAĞAÇLIOĞLU