Özet

Özet yok.

Özet (Çeviri)

Knowing the electrical conductivity and current density distribution inside the human brain will be useful in various biomedical applications, i.e. for improv-ing the efficiency of non-invasive brain stimulation (NIBS) techniques, the ac-curacy of electroencephalography (EEG) and magnetoencephalography (MEG) source localization, or localization of pathological tissues. For example, the ac-curacy of electric field simulations for NIBS techniques is currently reduced by assigning inaccurate ohmic conductivity values taken from literature to differ-ent brain tissues. Therefore, the knowledge of individual ohmic conductivity values may open up the possibility of creating more realistic and accurate head models, which may ameliorate the simulations and practical use of NIBS tech-niques. Magnetic resonance current density imaging (MRCDI) and magnetic resonance electrical impedance tomography (MREIT) are two emerging methods for cal-culating the current flow and for reconstructing the ohmic conductivity distri-bution inside the human brain. Both methods use measurements of the magnetic field ΔBz,c that are induced by weak currents applied via surface electrodes. The sensitivity of the measurements directly affects the accuracy of the current flow estimations and the quality of the reconstructed conductivity images. It in-creases with increasing strength of the injected currents that are limited to 1-2 mA for in-vivo human brain applications. Therefore, sensitivity improvements of the underlying MRI methods are crucial for implementing MRCDI and MREIT in neuroscience and clinical applications. In this thesis, systematic sensitivity and efficiency analyses of two different MRI pulse sequences, multi-echo spin echo (MESE) and steady-state free pre-cession free induction decay (SSFP-FID), are performed in order to optimize these sequences for in-vivo application in the human brain. The simulations are validated by comprehensive phantom experiments. Secondly, the optimized se-quences are tested for in-vivo human brain applications, and adapted to increase their robustness to physiological noise. The current-induced magnetic field ΔBz,c inside the brain is measured in different individuals, revealing inter-indi-vidual ΔBz,c differences due to anatomical variability. Finally, volume conduc-tor models of the individuals are created and used to simulate the current-in-duced ΔBz,c images and the current flow distributions. Comparison of the ΔBz,c and current flow simulations and measurements demonstrates a good corre-spondence. In summary, the results presented in this thesis pave the way for employing the optimized MRI sequences in future studies to improve the effi-ciency of NIBS techniques.

Benzer Tezler

  1. Normal popülasyonda miyokardiyal T1, T2 ve T2* değerlerinin yaş, cinsiyet ve kardiyak segmentlere göre analizi

    Analysis of myocardial T1, T2, and T2* values in normal population by age, gender, and cardiac segments

    ÇAĞRI ÖZCAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2023

    Radyoloji ve Nükleer TıpSağlık Bilimleri Üniversitesi

    Radyoloji Ana Bilim Dalı

    PROF. DR. HASAN YİĞİT

  2. Alzheimer demans hastalarında beyin manyetik rezonans görüntüleme volumetri ölçümleri ile nöropsikolojik testlerin ve beyin omurilik sıvısı biyobelirteçlerinin karşılaştırılması

    CSF biomarkers, neuropsychologic assessment (NPA) and magnetic resonance imaging (MRI) volumetry in Alzheimer's disease

    ANIL TANBUROĞLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2014

    NörolojiDokuz Eylül Üniversitesi

    Dahili Tıp Bilimleri Bölümü

    PROF. DR. GÖRSEV YENER

  3. Implantable sub-cm wireless resonators for MRI: From circuit theory to medical imaging

    MRG için implant edilebilir kablosuz cm-altı çınlaçlar: Devre teorisinden tıbbi görüntülemeye

    SAYIM GÖKYAR

    Doktora

    İngilizce

    İngilizce

    2017

    Mühendislik Bilimleriİhsan Doğramacı Bilkent Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    PROF. DR. HİLMİ VOLKAN DEMİR