Geri Dön

Bulk-fill kompozitler ile restore edilen sınıf II kavitelerin termo-mekanik yükleme sonrası servikal mikrosızıntısının değerlendirilmesi

Evaluation of the cervical integrity during thermo-mechanical loading of class II box cavities restored with bulk-fill composites

  1. Tez No: 522575
  2. Yazar: BİLGE ERSÖZ
  3. Danışmanlar: PROF. DR. GÜRKAN GÜR
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Bulk-fill composite, Microleakage, Thermo-mechanical loading, Dental materyaller, Dental restorasyon, Dental sızma, Kompozit reçineler, Polimerleşme, Bulk-fill composite, Microleakage, Thermo-mechanical loading, Dental materials, Dental restoration, Dental leakage, Composite resins, Polymerization
  7. Yıl: 2018
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Diş Hastalıkları ve Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu in-vitro çalışmanın amacı; bulk-fill kompozitler ile restore edilen proksimal kutu kavitelerin termo-mekanik yükleme sonrası mikroszıntı miktarını araştırmaktır. Bu çalışma için restoratif materyallerin dört farklı kombinasyonu (geleneksel akışkan kompozit+ geleneksel kompozit, geleneksel kompozit, akışkan bulk-fill kompozit + geleneksel kompozit+ bulk-fill kompozit) değerlendirilmiştir. Yeni çekilmiş üçüncü molar dişlere 160 adet proksimal kavite hazırlanmıştır. Mezial proksimal kavitelerin gingival kenarı mine-semet birleşiminin 1mm altında, distal proksimal kavitelerin gingival kenarı mine-sement birleşiminin 1mm üzerinde sonlanacak şekilde kaviteler prepare edilmiştir. Termo-mekanik yükleme öncesi ve sonrası (240.000 x 50 N, 5 ile 55 ° C arasında 2500 termosiklus), dişler 24 saat boyunca 23 ° C'de % 0.5'lik bazik fuksin boyasına batırılmıştır. Örneklerden alınan kesitler stereomikroskopta incelenmiştir ve mikrosızıntı skorları, üç yollu Kruskal-Wallis H ve Mann-Whitney-U testleri ile istatistiksel olarak değerlendirilmiştir (p<0,05). Dentin-sementte sonlanan restorasyonlar, mine-dentinde sonlanan restorasyonlara göre daha yüksek mikrosızıntı değeri göstermiştir. Termomekanik yüklemeye maruz kalan örneklerin mikrosızıntı miktarı artmıştır. Mine-dentinde sonlanan restorasyonlar, dentin-sementte sonlanan restorasyonlara göre termo-mekanik yüklemeden daha az etkilenmiştir. Restoratif materyallerin dört farklı kombinasyonu kıyaslandığında, kavitenin dentin-sementte sonlandığı ve termo-mekanik yükleme uygulandığı durumda; bulk-fill kompozitler, geleneksel kompozitlere göre mikrosızıntıyı önlemede daha başarılı olmuştur. Ancak geleneksel kompozitin altına kavite tabanına akışkan kompozit yerleştirildiğinde benzer mikrosızıntı sonuçları izlenmiştir.

Özet (Çeviri)

The purpose of this in vitro study was to evaluate the effects of thermo-mechanical loading on microleakage of proximal box cavities, which restored with bulk-fill composites. Four different combinations of restorative materials (conventional flow-able composite + conventional paste-like composite, conventional paste-like composite, bulk-fill flow-able composite + conventional paste-like composite, bulk-fill paste-like composite) were evaluated. One hundred sixty proximal box cavities were prepared in freshly extracted third molars. Gingival margins of the mesial proximal box cavities were terminated at the 1mm below the cemento-enamel junction and distal proximal box cavities were 1 mm above. Before and after thermo-mechanical loading (240,000 x 50 N, 2500 thermocycles between 5 and 55 °C), the teeth were immersed in a 0.5% basic fuchsin dye at 23°C for 24 hours. Sectioned samples were examined under a stereomicroscope. The results of cervical gingival microleakage scores were statistically evaluated using Kruskal-Wallis H and Mann-Whitney U tests (p<0.05). The restoration that ended at the dentin had a higher value of microleakage than the restorations that ended at the enamel. The amount of microleakage increased in samples exposed to thermomechanical loading. The restorations that ended at the enamel were less affected by the thermo-mechanical load than the restorations that ended at the dentin. When four different combinations of restorative materials are compared, when the cavity ends in a dentin and thermo-mechanical loading is applied, bulk-fill composites have been more successful in preventing microleakage than traditional composites. However, similar microleakage results have been observed when a flowable composite is placed underneath the conventional composite.

Benzer Tezler

  1. Isıtılmış kompozitlerle simante edilen indirekt inley restorasyonların gap oluşumu ve kırma dayanımının in vitro olarak değerlendirilmesi

    In vitro evaluation of gap formation and fracture resistance of indirect inlay restorations cemented with preheated composite resins

    ENGİN IŞIK

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2024

    Diş HekimliğiBezm-İ Alem Vakıf Üniversitesi

    Restoratif Diş Tedavisi Ana Bilim Dalı

    PROF. DR. EVRİM DALKILIÇ

  2. Süt dişlerinde bulk-fill kompozit rezinlerin mekanik özelliklerinin karşılaştırmalı değerlendirilmesi

    Comparative Evaluation of Mechanical Properties of Bulk-Fill Composite Resins in Primary Teeth

    GÖKÇE ŞAHİN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2017

    Diş HekimliğiEskişehir Osmangazi Üniversitesi

    Çocuk Diş Hekimliği Ana Bilim Dalı

    PROF. DR. ŞULE BAYRAK

  3. Rezin kompozit ve bulk fill cam hibrit restorasyon materyallerinin daimi dişlerde klinik ve radyografik olarak karşılaştırmalı değerlendirilmesi

    Clinical and radiographic comparative evaluation of resin composite and bulk fill glass hybrid restoration materials in permanent teeth

    FATMA ÜZÜMCÜ UYUMAZ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2021

    Diş HekimliğiNecmettin Erbakan Üniversitesi

    Pedodonti Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ MERVE ABAKLI İNCİ

  4. Derin marjin elevasyonu yapılan ve CAD/CAM inleyler ile restore edilen molar dişlerde mikro sızıntının değerlendirilmesi: Bir mikro BT çalışması

    Evaluation of microleakage in molars restored with CAD/CAM inlays following deep margin elevation: A micro-CT study

    BÜŞRA BAZNA

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2026

    Diş HekimliğiAtatürk Üniversitesi

    Restoratif Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. ÖMER SAĞSÖZ

  5. Direkt ve indirekt yöntemlerle uygulanan üç yüzlü kompozit restorasyonların termomekanik yükleme sonrası kenar uyumu ve mikrosızıntı açısından değerlendirilmesi

    Evaluation of mod restorations which are prepared with direct and indirect methods in terms of thermomechanical post-loading edge compatibility and microleakage

    AYŞE ASLI ŞENOL

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2020

    Diş HekimliğiMarmara Üniversitesi

    Restoratif Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. PINAR YILMAZ ATALI