Küçük alanlara ait dozimetrik parametrelerin farklı detektörlerle ölçülmesi
Measurement of parameters for small field dosimetry with various detectors
- Tez No: 515306
- Danışmanlar: DOÇ. DR. HİLAL ACAR DEMİR
- Tez Türü: Yüksek Lisans
- Konular: Fizik ve Fizik Mühendisliği, Onkoloji, Physics and Physics Engineering, Oncology
- Anahtar Kelimeler: Dedektörler, Doz-cevap ilişkisi-radyasyon, Penumbra, Radyometri, Radyoterapi, Detectors, Dose-response relationship-radiation, Penumbra, Radiometry, Radiotherapy
- Yıl: 2018
- Dil: Türkçe
- Üniversite: İstanbul Medipol Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Sağlık Fiziği Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Küçük alan dozimetrisinde, detektör boyutunun alan boyutuna eşit ya da büyük olması, penumbra ve detektör duyarlı hacminin kesişmesine yol açmaktadır. Ayrıca, lateral elektron dengesizliğinin başladığı alanlardan daha küçük alanlarda merkezi eksende birincil foton kaynağının kolimasyon tarafından parsiyel bloklanması ile parçacık spektrumu etkilenmektedir. Küçük alanlardaki bu sorunlar demet doz veriminde keskin bir düşüşe sebep olmaktadır. Dozimetrik ölçümlerde karşılaşılan bu belirsizliklerin en aza indirilmesinde doğru detektör seçimi de büyük rol oynamaktadır. Bu çalışmada, PTW Semiflex 31010 ve PTW Pinpoint 31014 ve referans detektör olarak PTW Microdiamond 60019 kullanılarak farklı enerjilerde ve alan boyutlarında yüzde derin doz, profil ve doz verimi ölçülmüştür. Yüzde derin doz eğrilerinde, alan boyutu küçüldükçe maksimum doz derinliğinin azaldığı, bu değişimin üç detektör incelemesi sonucunda etkin hacmi daha küçük olan PTW Pinpoint 31014 sonuçlarının PTW Microdiamond 60019 sonuçları ile uyumlu olduğu gözlemlenmiştir. PTW Semiflex 31010 sonuçlarında ise alan boyutu küçüldükçe yüzde farkın %37 lere çıktığı görülmüştür. Hacim ortalamasından kaynaklı bu farklılıklar profil ölçümlerinde de görülmektedir. Doz verimi ölçümlerine bakıldığında ise düzeltme faktörleri kullanılmadan önce detektörlerin verdiği yanıtlar birbirinden çok farklı iken TRS 483 protokolünden alınan her detektör ve her alan boyutuna özgü düzeltme faktörlerinin uygulanması ile detektörlerin verdiği yanıtlar birbiriyle uyumlu hale gelmiştir. Detektör yanıtları arasında en büyük fark PTW Semiflex 31010' da görülmüştür. Dozimetrik değerlendirmeler sonucunda, PTW 60019 Microdiamond detektörüne en yakın sonuçların PTW Pinpoint 31014 detektörü ile elde edildiği görülmüştür.
Özet (Çeviri)
In small field dosimetry, when detector size is equal to or larger than the field size penumbra and effective volume of the detector can be overlapped. In addition, in small fields that lateral electron inequilibrium occurs, primary photon source in central beam axis is blocked by the collimation and this effects the particle spectrum. These problems result in sharp decrease in beam output of small fields. In order to decrease the uncertainities during the measurements, selection of correct detector is vital. In this study we performed percentage depth dose, profile and output measurements in different field sizes with different photon energies using PTW Semiflex 31010 and PTW Pinpoint 31014 ionization chambers, and PTW 60019 PTW Microdiamond 60019 as a reference dosimeter. We investigated variation in detector readings for different energies and field sizes by means of acquired data and graphs. In percentage depth dose curves we observed decrease in depth of maximum for all detectors and consistency found between PTW Pinpoint 31014 and PTW Microdiamond 60019 results, while up to 37 % difference found from PTW Semiflex 31010 results with decreasing field sizes. This differences which results from volume averaging effect were also found in profile measurements. However output measurements of all detectors showed differences before applying correction factors, the results became consistent with eachother after applying correction factors of each according to TRS483. Maximum difference were seen in PTW Semiflex 31010 results. After evaluation of the dosimetric results of all detectors the closest results with PTW Microdiamond 60019 were seen in PTW Pinpoint 31014 results.
Benzer Tezler
- 6MV ve 18 MV foton enerjilerinde çok yapraklı kolimatör ve seroband alaşım blokların geometrik ve dozimetrik olarak karşılaştırılması
Dosimetric and geometric comparasion of multi leaf collimators and cerroband alloys at 6 and 18 MV photon energies
GÖRKEM GÜNGÖR
Yüksek Lisans
Türkçe
2007
OnkolojiHacettepe ÜniversitesiKlinik Onkoloji Ana Bilim Dalı
PROF. DR. MURAT GÜRKAYNAK
- Stereotaktik tedavilerde dozimetrik parametrelerin farklı dozimetre teknikleri kullanılarak karşılaştırılması
Comparison of dosimetric parameters using different dosimeter techniques in stereotactic treatments
CANAN ERTUNÇ ARSLANOĞLU
Yüksek Lisans
Türkçe
2008
OnkolojiEge ÜniversitesiRadyasyon Onkolojisi Ana Bilim Dalı
YRD. DOÇ. SERRA ARUN KAMER
- Mültilif kolimatör ve serrobent bloklarla oluşturulan düzensiz alanların verim faktörleri, kolimatör saçılma faktörleri ve fantom saçılma faktörlerinin ölçümü ve karşılaştırılması
Measurement and comparison of output factors, collimator scatter factors and phantom scatter factors of irregular fields shaped with cerrobend blocks and multileaf collimator
AYDAN GÜRSES
Yüksek Lisans
Türkçe
1999
OnkolojiHacettepe ÜniversitesiRadyasyon Fiziği Uygulamaları Ana Bilim Dalı
PROF. DR. İ. LALE ATAHAN
- Lineer hızlandırıcılarda fiziksel ve sanal kama filtrelerin karşılaştırılması ve dozimetrik değerlendirilmesi
The comparison and dosimetric assessment of physical and virtual wedge filters of linear accelerators
AYCAN ŞENGÜL
Yüksek Lisans
Türkçe
2011
OnkolojiUludağ ÜniversitesiRadyasyon Onkolojisi Ana Bilim Dalı
PROF. DR. GÖKAY KAYNAK
- Nadir toprak elementleri ile katkılandırılmış kompozit ince filmlerin sentezi, yapısal karakterizasyonu ve optik özelliklerinin incelenmesi
Synthesis and structural characterization of composite thin films doped with rare earth elements and investigation of optical properties
NESLİHAN AKKUŞ ERZURUM
Doktora
Türkçe
2020
Nükleer MühendislikEge ÜniversitesiNükleer Bilimler Ana Bilim Dalı
PROF. DR. MAHMUT ALİ ASKER ASLANİ