Geri Dön

Bulk fill kompozit rezinlerin mikrosertlik değeri ve dönüşüm derecesinin in vitro olarak değerlendirilmesi

In vitro assesment of bulk-fill composite resins in terms of conversion degree and microhardness

  1. Tez No: 508787
  2. Yazar: CANSU SEVİK
  3. Danışmanlar: PROF. DR. NURAY ATTAR
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Dental materyaller, Dental restorasyon, Kompozit reçineler, Mikrosertlik, Dental materials, Dental restoration, Composite resins, Microhardness
  7. Yıl: 2018
  8. Dil: Türkçe
  9. Üniversite: Hacettepe Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Restoratif Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu in vitro çalışmanın amacı, bulk fill kompozit rezinlerin mikrosertlik değeri ve dönüşüm derecesinin değerlendirilmesidir. Çalışmada, 5 adet bulk fill kompozit rezin [Filtek Bulk Fill Posterior (FB), 3M ESPE; Tetric EvoCeram Bulk Fill (TBF), Ivoclar Vivadent; SonicFill 2 Bulk Fill (SF), Kerr Co.; SDR Bulk Fill (SDR), Dentsply ve Venus Bulk Fill (VB), Heraeus Kulzer] ile 1 adet geleneksel kompozit rezin [Filtek Ultimate (FU), 3M ESPE] kullanılmıştır. Mikrosertlik değeri ve dönüşüm derecesini belirlemek için 6 mm çapında 1, 2, 3, 4 ve 5 mm kalınlığında teflon kalıplar kullanılarak ve kompozit rezinler bu kalıplar içerisine yerleştirilerek her bir kompozit rezin materyal için 30 adet (n=6), toplamda 180 adet örnek hazırlanmıştır. Örneklerin alt ve üst yüzey mikrosertlik [Vickers sertlik (HV)] değerleri ölçülmüştür. Her bir materyalden elde edilen farklı kalınlıktaki örneklerin, alt yüzey sertlik değeri üst yüzey sertlik değerine bölünerek dönüşüm dereceleri (DC) hesaplanmıştır. DC ve HV değerleri, Kruskal Wallis testi ve Dunn Sidak düzeltmesi kullanılarak istatistiksel olarak değerlendirilmiştir (p=0,05). Üst yüzeyde tüm kalınlıklarda en yüksek ortalama üst yüzey HV değeri (116,52± 1,32 N/mm2) SF grubunda 3 mm kalınlıkta, en düşük ortalama üst yüzey HV değeri (37,78±1,59 N/mm2) SDR grubunda 5 mm kalınlıkta gözlenmiştir. Alt yüzeyde en yüksek ortalama alt yüzey HV değeri (109,41±1,41 N/mm2) SF grubunda 1 mm kalınlıkta, en düşük ortalama alt yüzey HV değeri ( 33,47±1,26 N/mm2) SDR grubunda 5 mm kalınlıkta belirlenmiştir (p<0,05). DC % tüm materyallerde artan kalınlıkla düşmüş olup, ortalama DC %, en yüksek VB grubunda 1 mm kalınlıkta (% 97,07), en düşük FU grubunda 5 mm kalınlıkta (% 47,36) bulunmuştur (p<0,05). Bu çalışmada, tüm kompozit rezin gruplarında 1, 2, ve 3 mm kalınlıkta DC yüzdeleri eşik değer olan % 80'in üzerinde olduğu görülmüştür (p<0,05). Çalışmada, tüm gruplarda kompozit rezinin kalınlığı arttıkça alt yüzeydeki HV değerlerinin düştüğü ve kompozit rezin türünün HV ve DC değerlerini etkilediği görülmüştür.

Özet (Çeviri)

The aim of this in vitro study was to evaluate bulk fill composite resins in terms of microhardness and conversion degree. In the study, 5 bulk fill composite resins [Filtek Bulk Fill Posterior (FB), 3M ESPE; Tetric EvoCeram Bulk Fill (TBF), Ivoclar Vivadent; SonicFill 2 Bulk Fill (SF), Kerr Co.; SDR Bulk Fill (SDR), Dentsply and Venus Bulk Fill (VB), Heraeus Kulzer] and 1 conventional composite resin [Filtek Ultimate (FU), 3M ESPE] were used. Teflon molds with a diameter of 6 mm and 1, 2, 3, 4 or 5 mm in height were prepared and composite resins were placed in these molds to prepare 30 samples (n = 6) for each composite resin in total 180 samples. Then, the bottom and top surface microhardness [Vickers hardness (HV)] values were determined. The conversion degrees (DC) were calculated by dividing the top surface to the bottom surface hardness value of the samples. DC and HV values were statistically evaluated using the Kruskal Wallis test and Dunn Sidak correction (p = 0.05). The highest top surface HV value at all thicknesses was measured on the SF group at 3 mm (116.52 ± 1.32 N / mm2), and the lowest bottom HV value was measured on the SDR group at 5 mm (37.78 ± 1.59 N / mm2) (p<0.05). The highest bottom surface HV value was measured on the SF group at 1 mm (109.41 ± 1.41 N/mm2), and the lowest bottom HV value was measured on the SDR group at 5 mm (33.47 ± 1.26 N/mm2) (p<0.05). DC % decreased with increasing thickness in all materials and VB group showed the highest DC % (97.07 %) at 1 mm thickness, FU showed the lowest DC (47.36 %) at 5 mm thickness (p<0.05). In this study, DC % were above the threshold value of 80 % in all the composite resin groups at 1, 2 and 3 mm thicknesses (p<0.05). In all groups, as thickness of the composite increased, the bottom surface HV values decreased and it was found that composite resin type affected HV and DC values.

Benzer Tezler

  1. Halojen ve led ile polimerize edilmiş bulk fill kompozit rezinlerin dönüşüm derecesi ve mikrosertlik değerlerinin karşılaştırmalı olarak incelenmesi

    Comparative analysis of conversion degrees and microhardness values of bulk fill composite resins polymerized with different light devices

    MERVE KÜTÜK

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2018

    Diş HekimliğiOndokuz Mayıs Üniversitesi

    Restoratif Diş Tedavisi Ana Bilim Dalı

    PROF. DR. ERTAN ERTAŞ

  2. Bulk fill kompozit rezinlerin farklı tabaka kalınlıklarında ve farklı ışık güçlerinde polimerize edilmesinin kompozitin dönüşüm derecesi, mikro sertliği ve sitotoksisitesine etkisi

    Effect of polymerization of bulk fill composite resins in different layer thicknesses and light irradiance on the degree of conversion, micro hardness and cytotoxicity of the composite

    SEVDE GÜL BATMAZ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2020

    Diş HekimliğiAkdeniz Üniversitesi

    Restoratif Diş Tedavisi Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ AYŞE DÜNDAR

  3. Farklı fotobaşlatıcılar içeren kompozit rezinlerin mekanik özelliklerinin değerlendirilmesi

    Evaluation of mechanical properties of composite resins with different photoinitiators

    RAGHIB A.R. SURADI

    Doktora

    Türkçe

    Türkçe

    2019

    Diş HekimliğiGazi Üniversitesi

    Restoratif Diş Tedavisi Ana Bilim Dalı

    PROF. DR. HACER DENİZ ARISU

  4. Evaluation of the surface roughness and microhardness of three bulk fill nonflowable resin composites in comparison to one conventional resin compsite after polishing with different polishing systems

    Farklı cilalama işlemlerinden sonra üç akışkan olmayan bulk fill kompozit rezin ile geleneksel kompozit rezinin karışlaştırmalı olarak yüzey pürüzlülüğü ve mikrosertliğin değerlendirilmesi

    OSAMA SHENEEB

    Yüksek Lisans

    İngilizce

    İngilizce

    2015

    Diş HekimliğiYeditepe Üniversitesi

    Restoratif Diş Tedavisi Ana Bilim Dalı

    YRD. DOÇ. DR. MUSTAFA ERSOY

    PROF. ASIM MÜBİN SOYMAN

  5. Üç farklı posterior kompozit materyalinin sitotoksisite ve mikrosertlik açısından değerlendirilmesi

    Evaluation of cytotoxicity and microhardness of three different posterior composite materials

    ELMAS TÜFEK ATICI

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2017

    Diş HekimliğiDicle Üniversitesi

    Çocuk Diş Hekimliği Ana Bilim Dalı

    DOÇ. DR. BUKET AYNA