Ortodontik tedavide kullanılan elastik zincirlerin ortamdaki ısı değişimi, su emilimi ve zamana bağlı olarak kuvvet azalmasının değerlendirilmesi
The evaluation of force decay in elastomeric chains used for orthodontic treatment depending on thermal change, water absorbation and time
- Tez No: 507635
- Danışmanlar: DOÇ. DR. ZEHRA İLERİ
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Elastik zincir, Emilim, Kuvvet kaybı, Ortodontik apareyler, Absorpsiyon, Elastik malzeme, Kuvvet analizi, Ortodonti, Ortodontik aygıtlar, Absorption, Elastic chain, Force degradation, Orthodontic appliances, Elastic material, Force analysis, Orthodontics
- Yıl: 2018
- Dil: Türkçe
- Üniversite: Selçuk Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Bu çalışmanın amacı; farklı markalar tarafından üretilen elastomerik zincirlerde; ortamdaki ısı değişimi, su emilimi ve zamana bağlı olarak kuvvet azalmalarında görülen farklılığı karşılaştırmaktır. Beş farklı firmaya ait, farklı aralıklara ve özelliklere sahip elastik zincirler çalışmaya dahil edilmiştir. Elastomerik zincirlerin marka bazında su emilimine, zamana ve ortama bağlı olarak kuvvet kayıpları değerlendirilmiştir. Ölçümler 0. saatte, 1. saatte, 24. saatte, 3. günde, 1., 2., 3., ve 4. haftada manuel bir kuvvet ölçer kullanılarak tekrarlanmıştır. Zamana bağlı ortamlar ve markalar arasındaki farkı tespit amacıyla Anova testi, fark tespit edilen zamanlarda ikili karşılaştırmalar için Post-Hoc Tukey testi, ortamların zamana göre kuvvet azalış yüzdesi arasındaki farkın tespiti için tekrarlı Anova testi elastik zincirlerin istatistiksel karşılaştırması için kullanılmıştır. Anlamlılık p<0,05 olarak kabul edilmiştir. Markalar arası su emiliminde anlamlı bir fark bulunamamıştır (p>0,05). Kuru ortamda yapılan çalışmada markalar arasında 1. saat, 24. saat ve 3. günde yapılan ölçümlerde kuvvet azalış yüzdeleri arasında anlamlı bir fark bulunamazken (p>0,05), 1. hafta, 2. hafta, 3. hafta ve 4. haftada markalar arasında anlamlı bir fark tespit edilmiştir (p<0,05). Yapay tükürüklü ortamda 1. saatte markalar arası kuvvet azalış yüzdesi arasında anlamlı bir fark bulunamazken (p>0,05), 24. saatte, 3.günde, 1. hafta, 2. hafta, 3. hafta ve 4. hafta ölçümlerinde markalar arasında istatistiksel olarak anlamlı bir fark tespit edilmiştir (p<0,05). Termal sikluslu ortamda 1. saatte, 24. saatte, 3.günde, 1. hafta, 2. hafta, 3. hafta ve 4. hafta ölçümlerinde markalar arasında istatistiksel olarak anlamlı bir fark tespit edilmiştir (p<0,05). Markalar arasında su emilimi açısından fark yoktur. Ancak farklı ortamlarda ve farklı markalarda zamana bağlı olarak kuvvet kayıpları açısından anlamlı farklılık tespit edilmiştir.
Özet (Çeviri)
The aim of this study is to evaluate the force degradation of elastomeric chains produced by different brands in three different environments; air media, artificial saliva media, thermal cyclic media, and to measure the water absorption of chains. Elastic chains produced by different brands (5 brands), different spacings (continuous, short spaced, long spaced) and features (memory, conventional) are included in the study. The force degradation of elastomeric chains based on brand-based water absorption, time and different environments (air media, artificial saliva media, thermal cyclic media) are evaluated. Measurements were repeated using a manual force gauge at 0 hours, 1 hour, 24 hours, 3 days, 1, 2, 3, and 4 weeks. The Anova test was used to determine the time-dependent differences between the different environments and brands, the Post-Hoc Tukey test for binary comparisons at different time points, and the repeated Anova test was used for statistical comparison of elastic chains for determining the difference between percentages of strengths of environments. There was no significant difference in water absorption between brands (p> 0.05). In the study performed in the dry environment, there was no significant difference between the percentages of decrease in force at the 1st hour, 24th hour and 3rd day of the brands (p> 0.05), at the 1st week, 2nd week, 3rd week and 4th week there was a significant difference between brands (p <0.05). There was no statistically significant difference between the percentages of decrease in force between marks at 1 hour in artificial salivary media (p> 0.05), between the brands at 24th hour, 3rd day, 1st week, 2nd week, 3rd week and 4th week a statistically significant difference was found (p <0.05). A statistically significant difference was determined between the measurements at 1 hour, 24 hour, 3rd day, 1st week, 2nd week, 3rd week and 4th week in thermal cycle environment (p <0.05). There is no difference in water absorption between brands. However, significant differences were found in terms of force degradation depending on time in different environments and in different brands.
Benzer Tezler
- Profilaktik amaçla kullanılan florür solüsyonlarının titanyum bazlı tellerin yüzey özellikleri ve iyon salınımları üzerine olan etkilerinin incelenmesi
Evaluation of effects of prophylactic fluoride solutions on surface changes and ion release of titanium based orthodontic wires
İLKİN MAMMADOV
- Profilaktik amaçla kullanılan topikal florürün titanyum bazlı tellerin yüzey özellikleri ve sürtünme kuvvetlerine olan etkilerinin in vitro olarak incelenmesi
In vitro evaluation of effect of prophylactic topical flourides on surface changes and friction forces of titanium based orthodontic wires
İREM SAKARYA AKSU
- Farklı şeffaf plak materyallerinin fiziksel özelliklerinin karşılaştırılması
Başlık çevirisi yok
AHMET MURAT ARTUÇ
- Ortodontik elastik kullanımının temporomandibular eklem üzerinde oluşturduğu stresin sonlu elemanlar analizi ile değerlendirilmesi
Evaluation of stresses generated by orthodontic elastic use on temporomandibular joint using finite element method
VUGAR GURBANOV
Doktora
Türkçe
2018
Diş HekimliğiOndokuz Mayıs ÜniversitesiAğız, Diş ve Çene Cerrahisi Ana Bilim Dalı
DOÇ. BURCU BAŞ
- Maksiller gömülü kanin dişlerin ballista spring ve elastik iplik yöntemleriyle sürdürülmesinin sonlu elemanlar metoduyla karşılaştırılması
Comparision of the eruption of the maxillary impacted canine teeth using ballista spring and elastic thread procedures by finite elementh method
ALİ FURKAN KARAKOYUNLU
Diş Hekimliği Uzmanlık
Türkçe
2018
Diş HekimliğiGaziantep ÜniversitesiOrtodonti Ana Bilim Dalı
YRD. DOÇ. DR. AYŞEGÜL GÜLEÇ