Geri Dön

3g cep telefonlarından yayılan elektromanyetik radyasyonun akut ve kronik uygulamasının uyumsuzluk negativitesine etkisi ve mekanizması

The effect and mechanism of acute and chronic application of electromagnetic radiation from 3g mobile phones on mismatch negativity

  1. Tez No: 496963
  2. Yazar: HAKAN ER
  3. Danışmanlar: PROF. DR. PİRAYE YARGIÇOĞLU AKKİRAZ
  4. Tez Türü: Doktora
  5. Konular: Biyofizik, Biophysics
  6. Anahtar Kelimeler: Elektromanyetik Radyasyon, TBARS, GFAP, Glutamat Reseptörü, Uyumsuzluk Negativitesi, Cep telefonu, Elektromanyetik alanlar, Glutamat, Reseptörler, Electromagnetic Field, TBARS, GFAP, Glutamate Receptor, Mismatch Negativity, Cellular phone, Electromagnetic fields, Electromagnetic radiation, Glutamates, Receptors
  7. Yıl: 2018
  8. Dil: Türkçe
  9. Üniversite: Akdeniz Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Biyofizik Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Teknolojinin gelişmesiyle birlikte günlük yaşantımızda daha çok sayıda elektromanyetik radyasyon (EMR) yayan cihazlar kullanılmaktadır. Cep telefonlarının beyindeki elektriksel aktiviteleri etkileyebileceği iddia edilmiştir. Ayrıca 2100 MHz EMR'nin sıçan uyumsuzluk negativitesi (MMN) üzerine etkisini araştıran hiçbir çalışmaya rastlanmamıştır. Bu bilgiler ışığında, çalışmamızda 2100 MHz EMR'nin akut ve kronik uygulanmasının sıçan MMN bileşeni üzerine etkisi, biyokimyasal ve histolojik parametrelere ek olarak NMDA ve AMPA reseptörlerinin ekspresyonları ve astrogliosis karşılaştırılarak aydınlatılmaya çalışılmıştır. Her grupta 20 sıçan olan 1 haftalık; kafes kontrol (K1), sham (S1), EMR (E1) ve 10 haftalık; kafes kontrol (K10), sham (S10) EMR (E10) grupları oluşturulmuştur. Elektro manyetik alan grupları pleksiglas tüplerde günde 2 saat 2100 MHz EMR ile, sham grupları pleksiglas tüplerde EMR olmadan bekletilmişlerdir. Deney sonunda MMN'ler kaydedildikten sonra beyin dokuları çıkarılmıştır. AMPA reseptörü proteininin E1 grubunda K1 ve S1 gruplarına göre anlamlı derecede düşük ve E10 grubunda S10 grubuna göre anlamı derecede yüksek olduğu görülmüştür. Glial fibriller asidik proteinin (GFAP) E1 grubunda K1 ve S1 gruplarına göre anlamlı derecede yüksek ve E10 grubunda S10 grubuna göre anlamlı derecede düşük olduğu belirlenmiştir. Uyumsuzluk negativitesi ve olaya ilişkin potansiyel (OİP) genliklerinin E1 grubunda K1 ve S1 gruplarına göre düşük, E10 grubunda S10 grubuna göre yüksek olduğu gözlenmiştir. Ayrıca OİP delta ve teta güç spektrumlarının E1 grubunda K1 grubuna göre düşük, delta ve beta güç spektrumlarının E10 grubunda S10 grubuna göre yüksek olduğu izlenmiştir. Ek olarak OİP alfa koherensinin E1 grubunda K1 grubuna göre düşük, alfa ve teta koherenslerinin E10 grubunda S10 grubuna göre yüksek olduğu bulunmuştur. Sonuç olarak çalışmamızda, EMR'nin süreye bağlı olarak farklı etkiler gösterebileceğini ve kısa süreli uygulanması durumunda GluR2 proteinini azalttığı, GFAP proteinini artırdığı ve MMN genliklerini, güç spektrumunu ve koherensi azalttığı, uzun süreli uygulanmasında ise tam tersi etki oluşturduğu tespit edilmiştir.

Özet (Çeviri)

With the development of technology, more electromagnetic field (EMF) emitting devices are used in our daily life. It has been claimed that mobile phones may affect the electrical activities of the brain. Furthermore, no studies investigating the effect of 2100 MHz EMF on rat MMN were found. So, in our study we have investigated the effects of acute and chronic administration of 2100 MHz EMF on rat MMN by biochemical (TBARS, 4HNE) and histological (TEM) parameters in addition to the expression of NMDA and AMPA receptors and astrogliosis. One week; cage control (K1), sham (S1), EMF (E1) and 10 weeks; cage control (K10), sham (S10) and EMF (E10) groups (20 rats per group) were used. The electromagnetic field groups were kept in carousels with 2100 MHz EMF for 2 hours per day and sham groups were kept in carousels without EMF. At the end of the experiment, the brain tissues were collected after the MMNs were recorded. The AMPA receptor protein was observed to be significantly lower in the E1 group than K1 and S1 groups and higher in the E10 group than S10 group. Glial fibrillary acidic protein (GFAP) was found to be significantly higher in the E1 group than K1 and S1 groups and lower in the E10 group than S10 group. Mismatch negativity and ERP amplitudes were detected to be lower in the E1 group than K1 and S1 groups and higher in the E10 group than S10 group. In addition, the ERP delta and theta power spectra were lower in the E1 group than the K1 group and the delta and beta power spectra were higher in the E10 group than in the S10 group. Also, it was observed that ERP alpha coherence in E1 group was lower than K1 group, and alpha and theta coherences in E10 group were higher than S10 group. In conclusion, our study showed that EMF may have different effects depending on the duration. When it is administered for a short time, it increases GFAP protein and decreases GluR2 protein, MMN amplitude, power spectrum and coherence and when it is administered for a long time it has just the opposite effects.

Benzer Tezler

  1. 3G cep telefonlarından yayılan elektromanyetik radyasyonun görsel uyarılma potansiyellerine etkileri

    The effects of electromagnetic radiations emitted from 3G mobile phones on visual evoked potentials

    ENİS HİDİŞOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2015

    BiyofizikAkdeniz Üniversitesi

    Biyofizik Ana Bilim Dalı

    PROF. DR. PİRAYE YARGIÇOĞLU AKKİRAZ

  2. EM diffraction modeling with numerical methods

    Nümerik metotlarla elektromanyetik kırınım modelleme

    MEHMET ALPER USLU

    Doktora

    İngilizce

    İngilizce

    2016

    Elektrik ve Elektronik MühendisliğiDoğuş Üniversitesi

    Elektronik ve Haberleşme Mühendisliği Ana Bilim Dalı

    PROF. DR. ERCAN TOPUZ

  3. Deneysel siyatik sinir modelinde 900, 1800 ve 2100 MhZ elektromanyeitk alanın siyatik sinir iyilşemesi üzerine etkisi

    Effect of 900, 1800 and 2100 MhZ electromagnetic field on the rats models of siatic nerve healing

    CEMAL AKÇAY

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2016

    Plastik ve Rekonstrüktif CerrahiDicle Üniversitesi

    Plastik Rekonstrüktif ve Estetik Cerrahi Ana Bilim Dalı

    DOÇ. DR. CAFERİ TAYYAR SELÇUK

  4. Cep telefonu pillerinin asidik ortamda çözündürülerek metal miktarlarının tespiti ve hidroksitleri şeklinde çöktürülmesi

    Determination of the amount of metals in cell phone batteries by dissolving in acidic conditions and their precipitation as hyroxides

    BEGÜM ERÖZTÜRK

    Yüksek Lisans

    Türkçe

    Türkçe

    2005

    Çevre Mühendisliğiİstanbul Teknik Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    DOÇ. DR. İSMAİL TORÖZ

  5. GSM sistemlerinde uzaktan kontrol

    Remote control on GSM system

    BÜLENT ÖNEN

    Yüksek Lisans

    Türkçe

    Türkçe

    1999

    Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve Kontrolİstanbul Teknik Üniversitesi

    Bilgisayar Mühendisliği Ana Bilim Dalı

    DOÇ. DR. MEHMET BÜLENT ÖRENCİK