İşitme cihazlarının başlangıç ayarlarının gerçek kulak ölçümüyle değerlendirilmesi
Evaluation of initial fittings of hearing aids with real ear measurement
- Tez No: 494402
- Danışmanlar: PROF. DR. GÜNAY KIRKIM
- Tez Türü: Yüksek Lisans
- Konular: Kulak Burun ve Boğaz, Otorhinolaryngology (Ear-Nose-Throat)
- Anahtar Kelimeler: işitme cihazı, gerçek kulak ek kazanç, gerçek kulak ölçümü, Real ear measurement, hearing aid, real ear insertion gain
- Yıl: 2017
- Dil: Türkçe
- Üniversite: Dokuz Eylül Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Kulak Burun Boğaz Ana Bilim Dalı
- Bilim Dalı: Odyoloji Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
ÖZET Amaç: İşitme cihazlarının başlangıç ayarlarının hedef kazançlara ulaşma oranlarının gerçek kulak ek kazancıyla (GKEK) değerlendirilmesi amaçlandı. Gereç ve Yöntem: Araştırmaya otoskopik bakısı normal ve orta kulak patolojisi bulunmayan 24 birey (12 kadın ve 12 erkek) dahil edildi. Araştırmada farklı işitme cihazı (İC) markalarına ait üst segment iki dijital kulak arkası işitme cihazı karşılaştırıldı. GKEK ölçümlerini etkileyen kulak kalıbı, havalandırma deliği çapı, ses hortumu, işitme eşiği, başlangıç ayarları ve kazanç formülü gibi değişkenler sabitlendi. GKEK ölçümleri NAL-NL2 kazanç formülünde 55, 65 ve 75 dB SPL şiddetlerinde, Uluslararası Konuşma Test Sinyali (UKTS) kullanılarak 0.25, 0.5, 0.75, 1, 1.5, 2, 3, 4 ve 6 kHz'de ölçüldü. İşitme cihazlarının üç farklı şiddette ve dokuz ayrı frekansta elde edilen GKEK değerleri karşılaştırıldı. İşitme cihazlarının hedef kazançtan sapma miktarları ve hedef kazanca ulaşma yüzdeleri belirlendi. Bulgular: İşitme cihazlarının başlangıç ayarlarında elde edilen GKEK ortalamalarının NAL-N2 hedef kazançları ile örüşmediği saptandı. Başlangıç ayarındaki GKEK değerleri karşılaştırıldığında işitme cihazları arasında istatistiksel olarak anlamlı farklılık bulundu (p<0.05). Sonuç: Bu çalışmanın sonucunda işitme cihazlarının başlangıç ayarlarında elde edilen GKEK değerlerinin hedef kazançla örtüşmediği belirlendi. İşitme cihazı ayarlamalarında hedef kazançlara ulaşılabilmesi için gerçek kulak ölçümünün (GKÖ) kullanılması gerekli olduğu sonucuna varıldı.
Özet (Çeviri)
ABSTRACT Objective: It was aimed to evaluate the amount of obtaining the target gains of hearing aids (HAs) at their initial fittings by means of real ear insertion gain (REIG) scores. Material and Method: Twenty-four adults (12 women and 12 men) whose otoscopic examination was normal and had no middle ear pathology were includeding in to the study. In the study, two premium segment digital behind the ear hearing aids belonging to different brands were compared. Factors such as ear mold, ventilation diameter, sound tube, hearing threshold, initial fittings, and gain formula, which affects the REIG were fixed. NAL-NL2 was preferred as the gain formula. REIG scores were measured at the frequencies of 0.25, 0.5, 0.75, 1, 1.5, 2, 3, 4 and 6 kHz using the International Speech Test Signal (ISTS) at 55, 65 and 75 dB SPL intensities. REIG's of the HAs gathered at three different intensity and nine distict frequencies were compared.The amount of deviations from the target gains and percentage rates of attaining targets of hearing aids were determined. Results: Means of REIG scores of hearing aids obtained at their initial fittings were found to be lower than NAL-NL2 target gains. There was a siginificant difference between the hearing aids when they were compared with each other at their initial fittings (p<0.05). Conclusion: The study showed that REIG scores of two different brands of hearing aids obtained at their initial fittings could not attain their target gains. Therefore it was concluded that, in order to attain the target gains in hearing aid fittings, real ear measurement (REM) should be utilised.
Benzer Tezler
- Türkiye denizcilik sektöründe çalışma şartları (monografik bir etüd)
Başlık çevirisi yok
A.MURAT ASLANER
Yüksek Lisans
Türkçe
1988
İşletmeİstanbul ÜniversitesiÇalışma Ekonomisi ve Endüstri İlişkileri Ana Bilim Dalı
PROF. DR. TURAN YAZGAN
- Frekans sıkıştırma özelliği olan işitme cihazlarının işitsel çözünürlük üzerindeki etkisinin akustik değişim kompleksi ile incelenmesi
The effect of frequency compression on auditory resolution using acoustic change complex
EBRU KÖSEMİHAL
Doktora
Türkçe
2016
Kulak Burun ve BoğazMarmara ÜniversitesiKulak Burun Boğaz Ana Bilim Dalı
PROF. DR. FERDA AKDAŞ
- Hiperbarik oksijen tedavisi sırasında ve sonrasında transkütan oksijen basıncı düzeylerinin takibi
Moni̇tori̇ng transcutaneous oxygen pressure levels duri̇ng and after hyperbari̇c oxygen therapy
BEKİR ÖZCAN
Tıpta Uzmanlık
Türkçe
2025
Deniz ve Sualtı Hekimliğiİstanbul ÜniversitesiSualtı Hekimliği ve Hiperbarik Tıp Ana Bilim Dalı
PROF. DR. ŞAMİL AKTAŞ
- Preparation and characterization of carbon nanofiber added mesophase pitch based carbon foam
Karbon nanofiber ilave edilmiş mezofaz zift bazlı karbon köpüğün hazırlanması ve karakterizasyonu
AYŞENUR GÜL
Doktora
İngilizce
2012
Mühendislik Bilimleriİstanbul Teknik Üniversitesiİleri Teknolojiler Ana Bilim Dalı
PROF. DR. M. FERHAT YARDIM
- Identificaton of closed cavity facades in terms of condensation risk and energy performance
Kapalı boşluklu–çift cidarlı cephelerin yoğuşma riski ve enerji performans analizleri
AHMET BİLER
Yüksek Lisans
İngilizce
2015
Enerjiİstanbul Teknik ÜniversitesiEnerji Bilimi ve Teknolojileri Ana Bilim Dalı
DOÇ. DR. HATİCE SÖZER