Geri Dön

Sağlıklı erişkin bireylerde LS CE-chirp uyaran ve klik uyaran ile kaydedilen ekstra-timpanik elektrokokleografi yanıtlarının karşılaştırılması

Comparison of extra-tympanic electrocochleography test results using LS CE-chirp & clik stimulus in healty adult subjects

  1. Tez No: 493233
  2. Yazar: MEHMET RECAİ ARSLANTAŞ
  3. Danışmanlar: PROF. HATİCE SEYRA ERBEK
  4. Tez Türü: Yüksek Lisans
  5. Konular: Kulak Burun ve Boğaz, Otorhinolaryngology (Ear-Nose-Throat)
  6. Anahtar Kelimeler: Elektrokokleografi, ECochG, LS CE-Chirp, Akustik impedans testleri, Meniere hastalığı, Odyometri, Odyometri-uyarılmış cevap, Uyarılmış potansiyeller-işitsel, Electrocochleography, ECochG, Acoustic impedance tests, Meniere disease, Audiometry, Audiometry-evoked response, Evoked potentials-auditory
  7. Yıl: 2018
  8. Dil: Türkçe
  9. Üniversite: Başkent Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Kulak Burun Boğaz Hastalıkları Ana Bilim Dalı
  12. Bilim Dalı: Odyoloji Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Giriş ECochG ölçümleri; Méniere hastalığı, İşitsel nöropati spektrum bozukluğu tanısının konulması ve lezyon tarafının belirlenmesi, intraoperatif monitörizasyon ve koklear implant öncesi değerlendirmeler gibi farklı klinik uygulamalarda kullanılmaktadır. Bu çalışmada sağlıklı bireyler, yeni geliştirilen LS CE-Chirp uyaran ve klik uyaran ile ekstra-timpanik elektrokokleografi ölçüm metodu kullanılarak test edilmiş ve sonuçlar karşılaştırılmıştır. Materyal ve Metod Bu çalışma Ankara Başkent Üniversitesi Hastanesi KBB Anabilim dalı kliniğinde yapılmıştır. Çalışma grubunda 18 – 40 yaş arasında normal işitmeye sahip, 19 kadın (38 kulak) ve 4 erkek (8 kulak), toplam 23 kişi (46 kulak) dahil edilmiştir. Çalışmaya dahil edilen gönüllü bireylerin ayrıntılı bir anamnezi alınmış, kulak burun boğaz muayanesi yapılarak herhangi bir patoloji saptanmamış, odyometri testi ve immitansmetri ölçümleri yapılıp işitmesinin normal olduğu görüşmüş ve gönüllülerin test kriterlerine uygun olduğu ispatlandıktan sonra ECochG testleri yapılmıştır. Yapılan ECochG testleri klik ve LS CE-Chirp uyaranlar kullanılarak 90, 80 ve 70 dB nHL şiddetlerinde yapılmıştır. Elde edilen değerler, verilerin dağılımına uygun olarak istatistiksel olarak değerlendirilmiştir. Bulgular Hem klik hem de LS CE-Chirp uyaran kullanılarak ECochG testi yapılmıştır. 90 dB nHL şiddetinde SP/AP oranı, 80 dB nHL şiddetinde AP latansı, 70 dB nHL şiddetinde AP latansı ve SP/AP oranı değerlerinde klik ve LS CE-Chirp uyaranlarda istatistiksel olarak farklılık görülmüştür. Sonuç Altın folyo kaplı tip trode elektrot aracılığı ile LS CE-Chirp ve klik uyaranları kullanılarak yapılan ECochG testleri sonucunda istatiksel fark elde edilmiştir.

Özet (Çeviri)

Introduction ECochG testing is used for Méniere disease, auditory neuropathy spectrum disorder diagnosis, defining the side of the lesion, intraoperative monitorization and pre coclear implantation assesments in clinics. In this study, healty subjects were tested and evaluated with extra-tympanic electrocochleography method using LS CE-Chirp and click stimulus. Material and Method This study is held by Ankara Başkent University Hospital in the department of ENT. The work group was 19 woman (38 ears) and 4 men (8 ears), total of 23 subjects with the age range 18 – 40. All subjects anemnesis were taken in details and complete ENT examinations were done. ECochG testings were done after being sure there is no pathology with each subject, audiometric and immitansmetric testings were performed and all were confirmed to have healthy hearing. ECochG tests were performed with 90, 80 and 70 dB nHL levels using click and LS CE-Chirp stimuluses. All acquired data were analysed statistically according to the data distribution. Results Statistically significant values were acquired for ECochG testing with 90 dB nHL SP/AP ratio, 80 dB nHL AP latency, 70 dB nHL AP latency and SP/AP ratio by the use of click and LS CE-Chirp stimuluses. Conclusion ECochG test performed by the use of gold foil covered tip trode electrode, LS CEChirp and click stimulus had statistically significant results.

Benzer Tezler

  1. Sağlıklı erişkin bireylerde yapılan işitsel beyin sapı cevapları ölçümlerinde LS CE-chirp uyaran ve CE-chirp uyaran cevaplarının karşılaştırılması

    Comparison of ls ce-chirp versus ce-chirp abr results in healty subjects

    ENGİN DANİŞMEN

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    Kulak Burun ve BoğazBaşkent Üniversitesi

    Kulak Burun Boğaz Hastalıkları Ana Bilim Dalı

    PROF. DR. HATİCE SEYRA ERBEK

  2. Manisa ilinde sağlıklı bireylerde normal hemogram değerleri

    Başlık çevirisi yok

    EMİNE AYGÖR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2013

    HematolojiCelal Bayar Üniversitesi

    İç Hastalıkları Ana Bilim Dalı

    PROF. DR. ÜLKÜ ERGENE

  3. Obezite ile karotis ekstra-media kalınlığı arasındaki ilişki

    The relationship between obesity and carotid extra-media thickness

    ERHAN KAYA

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2013

    Çocuk Sağlığı ve HastalıklarıAbant İzzet Baysal Üniversitesi

    Çocuk Sağlığı ve Hastalıkları Ana Bilim Dalı

    YRD. DOÇ. DR. MERVAN BEKDAŞ

  4. Samsun ili erişkin populasyonunda tiroid hormonlarının referans aralıklarının belirlenmesi

    Başlık çevirisi yok

    MÜZEYYEN AYDEMİR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1999

    BiyokimyaOndokuz Mayıs Üniversitesi

    Biyokimya Ana Bilim Dalı

    DOÇ. DR. ABDULKERİM BEDİR

  5. Çocuklarda lipid profili ve D vitamini arasındaki ilişkinin değerlendirilmesi

    Evaluation of the relationship between lipid profile and vitamin d level in children

    SEÇİL AKAY YILMAZ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2022

    Çocuk Sağlığı ve HastalıklarıSağlık Bilimleri Üniversitesi

    Çocuk Sağlığı ve Hastalıkları Ana Bilim Dalı

    DOÇ. DR. AYNUR KÜÇÜKÇONGAR YAVAŞ