On iki haftalık mekanik vibrasyonun kök rezorpsiyonuna etkileri: Mikro – BT çalışması
The effect of twelve weekly mechanical vibration on root resorption: A micro-CT study
- Tez No: 493222
- Danışmanlar: YRD. DOÇ. DR. FETHİYE ÇAKMAK ÖZLÜ
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Kök rezorpsiyonu, Mekanik titreşim, Radyografi-dental, Tomografi, Vibrasyon, Root resorption, Mechanical vibration, Radiography-dental, Tomography, Vibration
- Yıl: 2017
- Dil: Türkçe
- Üniversite: Bülent Ecevit Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Bu çalışmanın amacı mekanik vibrasyonun, kuvvetuygulanan veya uygulanmayan üst birinci premolar dişlerdeki kök rezorpsiyonuna etkisini Mikro-BT ile araştırmaktır. Materyal Metot:Ortodontik tedavinin bir parçası olarak üst premolar dişlerinçekimigereken 20 hasta rastgele olarak iki gruba ayrıldı: grup 1, kuvvet uygulanan grup(150 g) ve grup 2, kuvvet uygulanmayan grup. 150 gram kontrollü bukkal devirme kuvveti, grup 1'deki her bir hastanın maksiller birinci premolar dişlerine 12 hafta boyunca uygulandı. Split-mouth prosedürünü kullanarak, hem grup 1 hem de grup 2'de her hastanın maksiller birinci premolar dişleri,“vibrasyon”ve“vibrasyonsuz”taraf olarak rasgele atandı. Çalışma için,“vibrasyon”tarafındaki maksiller birinci premolarlara, 10 dk/gün süre boyuncamodifiye edilmiş uca sahip Oral B HummingBird cihazı kullanılarak 113Hz'lik bukkal yönlü vibrasyon uygulandı. Kuvvet uygulama periyodundan sonra tüm hastalardan üst 1. premolar dişler çekildi. Kök yüzeyleri x-ışını mikrotomografi cihazında (SkyScan-1172, Belgium) tarandı. Elde edilen görüntülerde açık kaynaklı Fiji (ImageJ) yazılımı kullanılarak rezorpsiyon kraterlerinin hacimsel ölçümleri yapıldı. Bulgular:Vibrasyonlu ve vibrasyonsuz taraflar arasında kök rezorpsiyon hacimleri ve dağılımı açısından istatistiksel olarak bir fark yoktu(p>0.05). Kuvvet uygulanmayan gruba (grup 2) kıyasla kuvvet uygulanan grupta (grup 1) hacimce daha fazla rezorpsiyon mevcuttu (P<0.05). Sonuç: Bu çalışmanın sonuçlarına göre, mekanik vibrasyonun kök rezorpsiyonunu azaltmada yararlı bir etkisinin olmadığı vebukkal yönde 150 g kuvvet uygulamanınkök yüzeyinde önemli miktarda rezorpsiyona neden olduğu bulunmuştur.
Özet (Çeviri)
Aim: The purpose of this study was to investigate the effect of mechanical vibration on root resorption in the upper first premolar teeth with and without application of orthodontic force by Micro-CT. Material and Methods: 20 patients who required maxillary premolar extractions as part of their orthodontic treatment were randomly separated into two groups of five each: group 1, force application group (150 g) and group 2, no force group. A controlled buccal tipping force of 150 grams was applied on both maxillary first premolars of each patient in group 1 for 12 weeks. Using a split-mouth procedure, each patient's maxillary first premolar teeth were randomly assigned either“vibration”or“non-vibration”side in both group 1 and group 2. Buccally directed vibration of 113Hz, using an Oral B HummingBird device with a modified tip, was applied to the maxillary first premolar on the“vibration”side for 10mins/day during the study period. After the force application period, the upper premolars were extracted from all patients. The root surface was scanned with an x-ray desktop micro-tomograph (SkyScan-1172, Belgium). The resorption craters in each cross section were located individually and exported to Fiji (ImageJ), an open source software, which made slice-byslice quantitative volumetric measurements. Results: There was no statistical difference between the vibration and non-vibration sides in terms of root resorption volumes and distribution (p>0.05). There was more resorption by volume in the force application group (group 1) compared to no force group(group 2) (p<0.05). Conclusion:From the results of this study, mechanical vibration was not found to have a beneficial effect in reducing the amount of root resorption, and an application of 150 buccaly directed force caused a significant amount of resorption on which root surface.
Benzer Tezler
- Farklı sürelerdeki mekanik vibrasyonun ortodontik kuvvete bağlı oluşan kök rezorpsiyonuna etkisinin değerlendirilmesi: Mikro-BT çalışması
Evaluation of the effect of mechanical vibration for different durations on root resorption induced by orthodontic force: A micro-CT study
MEHMET GEDİK
Doktora
Türkçe
2015
Diş HekimliğiOndokuz Mayıs ÜniversitesiOrtodonti Ana Bilim Dalı
DOÇ. DR. SELMA TÜRKAN ELEKDAĞ TÜRK
- Term yenidoğanlarda topuk delme işleminde ağrı kontrolü için kullanılan mekanik vibrasyonun etkisi
The efficacy of mechanical vibration of heel stick pain in term neonates
FATOŞ NİMET DOLU
Yüksek Lisans
Türkçe
2013
HemşirelikMarmara ÜniversitesiÇocuk Sağlığı ve Hastalıkları Hemşireliği Ana Bilim Dalı
YRD. DOÇ. DR. AYŞE KARAKOÇ
- Vokal Kord nodülü olan bir müzisyende Doctorvox ses terapi tekniğinin etkisi
The effect of Doctorvox voice therapy technique on a musician with Vocal Cord nodule
SİMAY KARSLIOĞLU
Yüksek Lisans
Türkçe
2019
Güzel SanatlarErciyes ÜniversitesiMüzik Ana Sanat Dalı
DR. ÖĞR. ÜYESİ ALİ ÖZDEK
- The Effects of bridging analogies on high school students' misconceptions in mechanics
Birleştirici benzetme ve örnekleme yönteminin lise öğrencilerinin mekanik konularındaki kavram yanılgıları üzerindeki etkisi
SERKAN YILMAZ
Yüksek Lisans
İngilizce
2001
Eğitim ve ÖğretimOrta Doğu Teknik ÜniversitesiOrtaöğretim Fen ve Matematik Alanlar Eğitimi Ana Bilim Dalı
DR. ALİ ERYILMAZ
PROF.DR. ÖMER GEBAN
- Kronik mekanik bel ağrısında yatarak veya ayaktan uygulanan fizik tedavinin yaşam kalitesi ve fonksiyonel durum üzerine etkileri
The effects of inpatient or outpatient physical therapy on life quality and functional status mechanical low back pain
EMEL YEDELER UZ
Yüksek Lisans
Türkçe
2006
Fiziksel Tıp ve RehabilitasyonTrakya ÜniversitesiYRD. DOÇ. DR. H. ARAL HAKGÜDER