Portatif bir klinik analizörün sığırlarda kan iyonize kalsiyum konsantrasyonunu belirlemedeki geçerliliğinin araştırılması

The evaluation of validity a portable clinical analyzer for the determination of blood ionized calcium concentration in cattle

  1. Tez No: 489664
  2. Yazar: ÖZNUR YILMAZ
  3. Danışmanlar: PROF. DR. TOLGA KARAPINAR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Veteriner Hekimliği, Veterinary Medicine
  6. Anahtar Kelimeler: kalsiyum, sensitivite, süt ineği, portatif analizör, Duyarlılık, Süt inekleri, Sığırlar, İnekler, calcium, dairy cow, point-of-care (POC), sensitivity, Dairy cows, Cattles, Cows
  7. Yıl: 2018
  8. Dil: Türkçe
  9. Üniversite: Fırat Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Veterinerlik İç Hastalıkları Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Portatif bir analizör olan i-STAT'ın sığırlarda kan iyonize kalsiyum konsantrasyonunu belirlemedeki güvenilirliği hakkında sınırlı bilgi bulunmaktadır. Kan iyonize kalsiyum konsantrasyonunun portatif bir cihazla belirlenmesi, hayvanın kalsiyum durumunun hızlı bir şekilde değerlendirilmesine ve saha şartlarında etkili bir tedavinin yapılmasına imkân tanır. Bu çalışmanın amacı, i-STAT'ın sığırlarda kan iyonize kalsiyum konsantrasyonunu belirlemedeki güvenilirliğini değerlendirmektir. Bu çalışmada değişik hastalıklara sahip 121 sığır kullanılmıştır. Venöz kan örnekleri kan iyonize kalsiyum konsantrasyonunun belirlenmesi için i-STAT ve Radiometer ABL 800 analizörlerine uygulanmıştır. Elde edilen veriler karşılaştırma, doğruluk, uyum ve güvenilirliği ortaya koymak için eşli t testi, konkordans analizi, Passing-Bablok regresyon analizi ve Bland-Altman analizine tabi tutulmuşlardır. Radiometer ABL 800 referans metot olarak i-STAT ise test metodu olarak kabul edilmiştir. i-STAT'ın performansı, iki farklı kan iyonize kalsiyum konsantrasyonu eşik değerinde (< 1 mmol/L; <1.18 mmol/L) receiver operating characteristics (ROC) eğrisi ile değerlendirilmiştir. i-STAT ve Radiometer ABL 800 ile ölçülen ortalama kan iyonize kalsiyum konsantrasyonları benzer olarak belirlenmiştir (1.09 vs 1.09 mmol/L; P=.82). i-STAT'ın sonuçlarının Radiometer ABL 800 ile oldukça yüksek korelasyona sahip olduğu tespit edilmiştir (r= 0.98, P < .0001). i-STAT ile ölçülen kan iyonize kalsiyum (Y) ve Radiometer ABL 800 ile ölçülen kan iyonize kalsiyum konsantrasyonunun (X) regresyon eğrisi Y=-0.108276+1.103448×X olarak ortaya konulmuştur. Benzerlik çizgisinden sapma önemsiz olarak tespit edilmiştir (P = .64). Bland-Altman analizi ortalama hatanın olmadığını belirlemiştir. i-STAT < 1 mmol/L ve < 1.18 mmol/L kan iyonize kalsiyum konsantrasyonu eşik değerlerinde sırasıyla % 100 (95% güven aralığı, 87.7 – 100.0) ve % 94.8 (95 % güven aralığı, 87.2-98.6) sensitiviteye sahip olarak belirlenmiştir. Sonuç olarak, i-STAT sığırlarda kan iyonize kalsiyum konsantrasyonunu doğru bir şekilde belirlemiş ve özellikle hipokalsemiyi yüksek sensitivite ile tahmin etmiştir.

Özet (Çeviri)

Information on reliability of the i-STAT, a point-of-care (POC) device, to determine blood ionized calcium (iCa2+) concentration is limited. Rapid determination of blood iCa2+ concentration can help evaluation of calcium status and delivery of effective therapy in field conditions. The goal of this study was to evaluate reliability of the i-STAT (Abbott Point of Care, Abbott Laboratories, Chicago, IL) in measuring blood iCa2+ concentration in cattle. In this prospective study 121 cattle with various diseases were used. Venous blood samples were run the i-STAT and the Radiometer ABL 800 (Radiometer, Copenhagen, Denmark) analyzer for determination of blood iCa2+ concentration. Data were subjected to paired Student t-test, concordance analysis, Passing-Bablok regression and Bland-Altman plots for comparison, accuracy, agreement and reliability. The Radiometer ABL 800 was reference method however the i-STAT was the test method. The i-STAT performance was also evaluated at two different cut-off values for blood iCa2+ concentration (< 1 mmol/L; <1.18 mmol/L) using the receiver operating characteristics (ROC) curve. The mean blood iCa2+ concentration measured by the i-STAT was similar to the mean blood iCa2+ concentration measured by the Radiometer ABL 800 (1.09 versus 1.09 mmol/L; P = .82). The i-STAT results were highly correlated with the Radiometer ABL 800 results (r= 0.98, P < .0001). Regression equation fitting blood iCa2+ concentration measured by the i-STAT (Y) and blood iCa2+ concentration measured by the Radiometer ABL 800 (X), was Y= -0.108276+1.103448× X, with a residual deviation (RSD) of 0.02. The deviation from the identity line was not significant (P = .64). The Bland-Altman difference plot revealed that the mean bias was zero. The i-STAT had Se of 100 % (95% CI, 87,7 - 100,0) and Se of % 94.8 (95 % CI, 87.2-98.6) at the cut-off blood iCa2+ concentration < 1 and < 1.18 mmol/L, respectively. The i-STAT yielded precise and accurate blood iCa2+ results in cattle. The i-STAT especially predicted hypocalcemia with high sensitivity.

Benzer Tezler

  1. Portatif bir klinik analizörün sığırlarda kan üre nitrojen, plazma kreatinin, sodyum, klor, potasyum konsantrasyonlarını belirlemedeki geçerliliğinin araştırılması

    The evoluation of validity aportable clinical analyzer for the determination of blood urea, nitrogen plasma creatinine, sodium,chloride, potassium in cattle

    ESENGÜL YILDIRIM

    Yüksek Lisans

    Türkçe

    Türkçe

    2014

    Veteriner HekimliğiFırat Üniversitesi

    Veterinerlik İç Hastalıkları Ana Bilim Dalı

    DOÇ. DR. TOLGA KARAPINAR

  2. Bel ağrısı vakalarına uygulanmak üzere deri yüzeyinden yeni bir sinir uyarıcı geliştirilmesi

    Development of a new transcutaneous electrical nerve stimulator to manage low back pain

    AYŞEN ERDEM

    Yüksek Lisans

    Türkçe

    Türkçe

    2004

    BiyofizikGaziantep Üniversitesi

    Biyofizik Ana Bilim Dalı

    PROF.DR. METİN TULGAR

  3. Analysing brainwaves with a portable EEG device via mobile platforms

    Portatif EEG cihazıyla beyin dalgalarının mobil platformlarda analiz edilmesi

    TUĞÇE KALKAVAN

    Yüksek Lisans

    İngilizce

    İngilizce

    2016

    Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve KontrolYaşar Üniversitesi

    Bilgisayar Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. İBRAHİM ZİNCİR

  4. Hemiplejik hastalarda torakal manuel terapinin solunum kapasitesi üzerine akut etkisinin incelenmesi

    İmmediate effect of thoracal manual therapy on respiratory capacity in hemiplegic patients

    KENAN GÜL

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Fizyoterapi ve Rehabilitasyonİstanbul Okan Üniversitesi

    Fizik Tedavi ve Rehabilitasyon Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ EMİNE ATICI

  5. Taşınabilir torasik biyoempedans monitör tasarımı

    Portable thoracic bioimpedance monitor design

    OYA KÖKSAL

    Yüksek Lisans

    Türkçe

    Türkçe

    2020

    Mühendislik BilimleriBaşkent Üniversitesi

    Biyomedikal Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ ORHAN ERDEM HABERAL