CAD/CAM restorasyonların termomekanik yaşlandırılmasının kırılma dayanımına etkisinin incelenmesi
Investigation of the influence of thermomechanical aging on the fracture strength of CAD/CAM restorations
- Tez No: 487691
- Danışmanlar: YRD. DOÇ. DR. IŞIL SARIKAYA
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: CAD/CAM, kırılma dayanıklılığı, çiğneme simülatörü, yorgunluk, Cam seramikler, Dental porselen, Dental stres analizi, Kronlar, Kırılma dayanımı, Termomekanik, Yaşlandırma, Çiğneme, CAD/CAM, fracture strength, chewing simulator, fatigue, Glass ceramics, Dental porcelain, Dental stress analysis, Crowns, Thermomechanical, Ageing, Mastication
- Yıl: 2017
- Dil: Türkçe
- Üniversite: Gaziosmanpaşa Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Bu çalışmanın amacı termomekanik yaşlandırma işlemi uygulanan ve uygulanmayan lityum disilikat ile güçlendirilmiş cam seramik kronlar ile hibrit seramik monolitik blokların kırılma dayanıklılıklarının karşılaştırılmasıdır. Yöntem: Çekilmiş 60 adet molar diş üç grup oluşacak şekilde (n=20) bölünmüştür. Her test grubu için, Cerasmart (GC, Japonya), Vita Enamic (Vita Zahnfabrik, Almanya) ve IPS e.max CAD (Ivoclar Vivadent, Liechtenstein) monolitik blokları ile tam kron restorasyonları üretildi. 20'şer örnekli gruplarda örneklerin (n=10) yarısına dual akslı çiğneme simülatörü ve termal siklus (5°C-55°C, 6000 siklus) ile yaşlandırma işlemi uygulanırken diğer örneklere (n=10) yaşlandırma uygulanmamıştır. Çiğneme simülatöründe (50N, 1.1 Hz, lateral hareket:1mm, ağız açıklığı:2mm) ile steatit antagonistler ile 5 yıllık yaşlandırmayı taklit etmek için distile su solüsyonu içerisinde 1.200.000 siklus uygulanacak şekilde yaşlandırma işlemi uygulandı. Daha sonra tüm örneklerin kırılma dayanıklılık değerleri üniversal test makinesinde değerlendirildi. İstatistiksel analiz ölçümlerinin gruplar yönünden farklılığı tekrarlı ölçümlerde Varyans analizi kullanılarak değerlendirildi (p<0.05). Bulgular: En yüksek kırılma dayanıklılığı değeri yaşlandırma işlemi uygulanmayan IPS e.max CAD kronlarda görülürken (3098,4±667,09 N), en düşük kırılma dayanıklılık değeri ise yaşlandırma işlemi uygulanan Vita Enamic (1978,71±364,05 N) kronlarda vi görülmüştür. Yaşlandırma işlemi sonrasında ise Vita Enamic kronlar kırılma dayanıklılığı değerlerine göre, IPS e.max CAD ve Cerasmart kronlardan istatistiksel olarak anlamlı derecede farklı bulunmuştur. Yaşlandırma işleminin ise tüm gruplar içerisinde anlamlı bir farklılığa neden olmadığı belirlenmiştir. Sonuçlar: Çalışmamızda kullanılan tüm CAD/CAM monolitik kron restorasyonlarının dayanıklılığının klinik olarak kabul edilebilir sınırlarda olduğu ve 5 yıllık yaşlandırma işlemine karşı dayanıklı oldukları tespit edilmiştir.
Özet (Çeviri)
Aim: The purpose of this study is to compare the fracture strength of hybrid ceramic monolithic blocks with glass ceramic crowns reinforced with lithium disilicate without and with thermomechanical aging. Material and methods: Sixty extracted molar teeth were divided into three test group (n=20). For each test group, full crown restorations were fabricated from Cerasmart (GC, Japon), Vita Enamic (Vita Zahnfabrik, Germany) and IPS e.max CAD (Ivoclar Vivadent) monolithic blocks in our study. Aging was not applied to other specimens (n = 10), while dual axis chewing simulator and thermal cycle (5°C-55°C, 6000 cycles) were applied to half of the samples in 20 sample groups (n = 10). Aging was performed in a chewing simulator (50N, 1.1 Hz, lateral movement: 1 mm, mouth opening: 2 mm) to apply 1,200,000 cycles to mimic 5-years aging with steatite antagonists in distilled water solution. Then, fracture strength values of all samples were evaluated in an universal testing machine. Statistical analysis, the differences of the measures in terms of groups were evaluated using repeated measures of Variance analysis (p <0.05). Results: While the highest fracture strength value was appeared in IPS e.max CAD crowns (3098,4±667,09 N) without aging, the lowest fracture strength value was observed with aging Vita Enamic (1978,71±364,05 N) crowns. After the aging process, according to fracture strength values, Vita Enamic crowns were statistically significantly different from IPS e.max CAD and Cerasmart crowns. It was determined viii that aging did not cause a significant difference in all groups. Conclusions: The durability of all CAD/CAM monolithic crown restorations used in our work was found clinically acceptable limits and resistant to 5 years aging process.
Benzer Tezler
- İki farklı adeziv siman ile simante edilmiş implant destekli CAD/CAM monolitik kron restorasyonların dinamik yükleme sonrası kırılma dayanımlarının değerlendirilmesi
Evaluation of fracture resistance after dynamic loading of implant supported CAD/CAM monolithic crown restorations with two different adhesive cements
KAAN CEVAT ŞALVARLI
Diş Hekimliği Uzmanlık
Türkçe
2020
Diş HekimliğiAydın Adnan Menderes ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DR. ÖĞR. ÜYESİ ESRA TALAY ÇEVLİK
- Aşırı kron harabiyeti olan kanal tedavisi görmüş dişlerde CAD/CAM ile yapılan restorasyonların kırılma dirençlerinin karşılaştırılması
Comparison of fracture resistance of restorations made with CAD/CAM in root canal treated teeth having severe crown damages
ATA HİKMET TİMUR
Diş Hekimliği Uzmanlık
Türkçe
2019
Diş HekimliğiOndokuz Mayıs ÜniversitesiEndodonti Ana Bilim Dalı
DOÇ. DR. İSMAİL UZUN
- Evaluation of marginal adaptation of crowns fabricated with three different zirconia CAD-CAM materials
Üç farkli zirkonyum CAD-CAM materyali ile üretilen kuronların marjinal adaptasyonunun değerlendirilmesi
RİYAD DERVİŞ
Yüksek Lisans
İngilizce
2019
Diş HekimliğiMarmara ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DR. ÖĞR. ÜYESİ CEREN KÜÇÜK
- Direkt ve indirekt yöntemlerle uygulanan üç yüzlü kompozit restorasyonların termomekanik yükleme sonrası kenar uyumu ve mikrosızıntı açısından değerlendirilmesi
Evaluation of mod restorations which are prepared with direct and indirect methods in terms of thermomechanical post-loading edge compatibility and microleakage
AYŞE ASLI ŞENOL
Diş Hekimliği Uzmanlık
Türkçe
2020
Diş HekimliğiMarmara ÜniversitesiRestoratif Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. PINAR YILMAZ ATALI
- Üç boyutlu yazıcı ile farklı rezinlerden üretilen dental restorasyonların mekanik özelliklerinin incelenmesi
Mechanical analysis of 3D printed dental restorations produced from different resins
BUSE ÇEBİ GÜL
Diş Hekimliği Uzmanlık
Türkçe
2023
Diş Hekimliğiİnönü ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DR. ÖĞR. ÜYESİ NAGEHAN BAKİ
DOÇ. DR. FATİH DEMİRCİ