Geri Dön

Kardiyopulmoner resüsitasyon kalitesini artırmada metronom kullanımının yeri

Role of using metronome for improving the quality of cardiopulmonary resuscitation

  1. Tez No: 474037
  2. Yazar: DİKMEN ÇALIŞKAN
  3. Danışmanlar: DOÇ. DR. FİKRET BİLDİK
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: İlk ve Acil Yardım, Emergency and First Aid
  6. Anahtar Kelimeler: Acil servis-hastane, Acil tıp, Kalp durması, Kardiyopulmoner reanimasyon, Metronom, Emergency service-hospital, Emergency medicine, Heart arrest, Cardiopulmonary resuscitation, Metronome
  7. Yıl: 2017
  8. Dil: Türkçe
  9. Üniversite: Gazi Üniversitesi
  10. Enstitü: Tıp Fakültesi
  11. Ana Bilim Dalı: Acil Tıp Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Giriş ve amaç: Kardiyopulmoner resüsitasyon (KPR) kılavuzları kaliteli KPR'nin hasta sağ kalım ve nörolojik sonuçlarını olumlu etkilediğini belirtmektedir. Bu çalışmada metronom cihazının profesyonel sağlık çalışanlarının uyguladığı KPR kalitesi üzerine etkisinin araştırılması amaçlanmıştır. Gereç ve Yöntem: Bu çalışma prospektif, simülasyon tabanlı, tek kör bir klinik çalışma olarak tasarlanmıştır. Haziran ve Ağustos 2017 tarihleri arasında Gazi Üniversitesi Tıp Fakültesi Hastanesi Yoğun bakımlarında çalışan 102 araştırma görevlisi çalışmaya katılmıştır. KPR performansları klasik tipte ve metronom cihazı eşliğinde olmak üzere iki oturum şeklinde yapılmıştır. Erişkin tip maket üzerinde 2 dakika süren KPR performansları TrueCPR Coaching Device® ile kayıt edilmiştir. KPR performansları boyunca kompresyon kalitesi, dekompresyon kalitesi ve dakikada ortalama göğüs kompresyon hızı kaydedilmiştir. Araştırmaya katılan hekimlerin cinsiyet, boy, kilo, beden kitle indeksi (BKİ) gibi özellikleri kaydedilmiştir. Ayrıca katılımcılara metronom cihazının uyguladıkları KPR üzerine etkileri sorulmuştur. Bulgular: Çalışmaya katılanların 39'u (%32,8) bayan, yaş ortalaması 28,02±2,6 yıl, BKİ ortalaması 24,52±2,92 kg/m2 idi. Metronom cihazı eşliğinde yapılan KPR'de klasik yönteme kıyasla kompresyon kalitesi, dekompresyon kalitesi ve bası hızlarında istatistiksel olarak anlamlı iyileşme bulunmuştur (sırasıyla, p=0.001 p=0.001, p=0.001). Metronom kullanımı BKİ <25 kg/m2 olanlarda kompresyon kalitesini anlamlı oranda artırmaktadır (p=0.015). BKİ'nde 1 birimlik artışın kompresyon skorunda yaklaşık 2,5 birim artışa neden olduğu belirlenmiştir (B=2,45, p<0,001). Katılımcıların 68'i (%66,7) KPR sırasında kesinlikle metronom cihazı kullanmayı tercih edeceklerini belirtmiştir. Sonuç: Kardiyopulmoner resüsitasyon esnasında metronom cihazı kullanılması kompresyon ve dekompresyon kalitesini arttırmaktadır ve göğüs basısı hızını iyileştirmektedir.

Özet (Çeviri)

Introduction: Cardiopulmonary resuscitation (CPR) guidelines emphasize the importance of quality of CPR in improving outcomes. In this study, We was aimed to investigate the effect of metronome device on CPR quality. Materials and Methods: This study was designed as a prospective, simulation-based, single-blind clinical trial. The residents working in intensive care unit at Gazi University Medical Faculty Hospital were enrolled to the study between June and August 2017. CPR performances were conducted in two sessions, classical type and with metronome device. An adult type manikin was used in this study. CPR was applied for two minutes and performances were recorded with TrueCPR Coaching Device®. Compression quality, decompression quality and mean chest compression rate were recorded at both sessions. Participants's characteristics such as gender, height, weight, body mass index (BMI) were recorded. In addition, participants were asked about the effects of the metronome device on CPR. Results: Hundred and two residents were enrolled in the trial (32,8% female, average age 28,02±2,6 years and average BMI 24,52±2,92 kg/m2). The compression quality, decompression quality and mean chest compression rate were statistically significantly improved in CPR with metronome device. (respectively,p=0,001, p=0,001 and p=0,001). Metronome use statistically significantly improved compression quality in BMI <25 kg/m2 (p=0.015). One kg/m2 increase in the BMI was found to cause an increase of about 2.5% in the compression quality score (B = 2.45, p <0.001). 66.7% of the respondents said they would definitely prefer to use the metronome device during CPR. Conclusion: Using a metronome device during CPR increases the quality of compression and decompression. Also the rate of chest compressions during CPR can be optimized by the use of a metronome device.

Benzer Tezler

  1. Kardiyopulmoner resüsitasyon esnasında spontan dolaşımın yeniden sağlanmasını öngörmek amacı ile serebral perfüzyon monitorizasyonunun kullanımı

    The use of cerebral perfusion monitoring to predict return of spontaneous circulation during cardiopulmonary resuscitation

    GÖKSELİN BELELİ YAŞAR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2021

    İlk ve Acil YardımSağlık Bilimleri Üniversitesi

    Acil Tıp Ana Bilim Dalı

    DOÇ. DR. ABDULLAH ALGIN

    DOÇ. DR. SERKAN EMRE EROĞLU

  2. Tıp eğitiminde simülasyonun önemi ve simülasyon eğitimi ile acil tıp ekibinin kardiyopulmoner resüsitasyon uygulamasında takım performansının artırılması

    The importance of simulation in medical education and improving the emergency team performance on cardiopulmonary resuscitation by using simulation based education

    DEMET ARI YILMAZ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2014

    İlk ve Acil YardımGaziantep Üniversitesi

    Acil Tıp Ana Bilim Dalı

    PROF. DR. CUMA YILDIRIM

  3. Otomatik eksternal defibrilatör ile kardiyopulmoner resüsitasyon feedback cihazının birlikte kullanımının kardiyak arrest durumunda halktan kurtarıcıların kpr kalitesine etkisi

    The effect of the combined use of automated external defibrillators and cpr feedback devices on the quality of cardiopulmonary resuscitation performed by laypersons during cardiac arrest

    SILA EKER KOYUNBAKAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2025

    Acil TıpSağlık Bilimleri Üniversitesi

    Acil Tıp Ana Bilim Dalı

    DOÇ. DR. NAZLI GÖRMELİ KURT

  4. Özel bir piston ve kilit mekanizmasına sahip yüksek başlangıç ivmeli göğüs kompresyon cihazının tasarımı, simülasyonu ve üretimi

    Design, simulation, and fabrication of a high initial acceleration automatic chest compression device with a special piston and locking mechanism

    AHMET KAĞIZMAN

    Doktora

    Türkçe

    Türkçe

    2024

    Mekatronik Mühendisliğiİstanbul Teknik Üniversitesi

    Mekatronik Mühendisliği Ana Bilim Dalı

    PROF. DR. VOLKAN SEZER

  5. Paramedik, acil tıp teknisyeni, paramedik bölümü öğrencilerinin erişkin temel yaşam desteği uygulama kalitesi ile kurtarıcı özellikleri ve uygulama pozisyonu arasındaki ilişkinin değerlendirilmesi

    Paramedic, emergency medical technician, paramedic department students' adult basic life support application quality and rescuer characteristics and evaluation of the relationship between application position

    BİLAL DURMUŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    İlk ve Acil YardımSelçuk Üniversitesi

    İlk ve Acil Yardım Ana Bilim Dalı

    DOÇ. DR. HASAN KARA