Geri Dön

Konvansiyonel metal braket ve estetik seramik braket ile sabit ortodontik tedavi gören farklı hasta gruplarında kaygı ve ağrı durumlarının psikometrik ve biyokimyasal ölçümlerle incelenmesi

Investigation of anxiety and pain conditions of different groups of fixed orthodontic therapy patients treated with conventional metal brackets and aesthetic ceramic brackets by psychometric and biochemical measurements

  1. Tez No: 473694
  2. Yazar: SERA AKKAYA BERMEDE
  3. Danışmanlar: PROF. DR. AYŞEGÜL KÖKLÜ
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Anksiyete, Ağrı, Dental anksiyete, Hidrokortizon, Ortodonti, Ortodontik aygıtlar, Ortodontik braketler, Tükürük, Ölçekler, İmmünoglobülin A, Anxiety, Pain, Dental anxiety, Hydrocortisone, Orthodontics, Orthodontic appliances, Orthodontic brackets, Saliva, Scales, Immunoglobulin A
  7. Yıl: 2017
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Prospektif olarak tasarlanan bu çalışmada hedef metal braketler ile seramik braketler kıyaslandığında hastaların anksiyete düzeylerinin STAI test skoru, tükrük kortizol ve sIgA miktarları; ağrı düzeylerinin ise Vizüel Analog Skala (VAS) ile tedavinin bonding seansından 24 saat, 7 ve 30 gün sonra yapılan ölçümlerde incelenmesidir. Araştırmaya Ankara Üniversitesi Diş Hekimliği Fakültesi Ortodonti Anabilim Dalı'na dişlerindeki çapraşıklık şikayeti nedeniyle başvuran ve tedavi endikasyonu bulunan daimi dentisyon dönemindeki maksiller ve mandibuler çapraşıklık miktarları az/orta şiddette olan (< 7 mm), 12-18 yaş arasındaki toplam 29 adölesan dahil edilmiştir. Metal grubunda ortalama yaşı 13,91±1,83 yıl olan 8 kız, 7 erkek; porselen grubunda ise ortalama yaşı 15,36±1,89 yıl olan 8 kız, 6 erkek bulunmaktadır. Çalışmada gruplar arası farklılığın incelenmesinde bağımsız t-testi ve Mann Whitney U teslerinden; grup içi zamana bağlı değişimlerin saptanmasında bağımlı t-testi ve Wilcoxon işaret testlerinden yararlanılmış; parametreler arası ilişki değerlendirilirken de korelasyon analizi kullanılmıştır. Araştırma bulgularına göre maksimum ağrı seviyeleri her iki grupta da birinci gün sonunda kaydedilmiştir (VAS metal mean=5,03, VAS metal max=7; VAS porselen mean=5,04, VAS porselen max=7). Bir hafta sonra her iki grupta da ağrı belirgin olarak azalmış; bir aylık takipte ise minimal düzeyde devam etmiştir. 30. günde metal grubun VAS skor ortalaması porselen grubun VAS skor ortalamasından anlamlı derecede daha büyük bulunmuştur. Metal ve porselen gruplarında farklı zamanlarda ölçülen sIgA ve kortizol konsantrasyon ortalamaları arasında anlamlı düzeyde farklılık bulunmamaktadır. Sonuç olarak sabit mekaniklerin uygulandığı hasta gruplarında oluşan rahatsızlık hissi ve kaygı durumlarının psikosomatik semptomların oluşumuna sebebiyet verecek boyutlara ulaşamadığı görülmektedir.

Özet (Çeviri)

The aim of this prospective study is to compare metal brackets and ceramic brackets by examining patients' anxiety levels with STAI test score, salivary cortisol and sIgA concentrations; pain levels with visual analog scale (VAS) assessed 24 hours, 7 and 30 days after bonding session of treatment. The study comprises of 29 adolescents at permanent dentition, aged between 12-18 years who presented to Ankara University Faculty of Dentistry, Orthodontics Department due to crowding teeth, and who had mild/moderate (<7 mm) maxillary and mandibular crowding with treatment indication. The metal group included 8 females and 7 males with a mean age of 13.91±1.83 years; and the porcelain group included 8 females and 6 males with a mean age of 15.36±1.89 years. Differences between the groups were analyzed with independent t-test and Mann Whitney U test; time-related changes within the groups were detected with dependent t-test and Wilcoxon sign test. Relationships between parameters were evaluated with correlation analysis. According to the study results, maximum pain levels were recorded at the end of the first day in both groups (VAS metal mean=5.03, VAS metal max=7; VAS porcelain mean=5.04, VAS porcelain max=7). In both groups, pain levels showed significant reduction a week later, whereas the pain persisted at minimal level during one-month follow-up. On the 30th day, mean VAS score was significantly higher in the metal group than in the porcelain group. There was no statistically significant difference between metal and porcelain groups regarding mean sIgA and cortisol concentrations measured at different times. In conclusion, it is observed that the feeling of discomfort and anxiety states in patients undergoing fixed orthodontic treatment do not reach levels that would cause development of psychosomatic symptoms.

Benzer Tezler

  1. Farklı braket türlerinde nikel ve krom salınımının in vivo incelenmesi

    In vivo examination of nickel and chromium release from different types of brackets

    TUNCAY SARMAZ

    Doktora

    Türkçe

    Türkçe

    2013

    Diş HekimliğiGazi Üniversitesi

    Ortodonti Ana Bilim Dalı

    PROF. DR. LALE TANER

  2. Farklı kapaklı braket tipleri ve konvansiyonel braketlerle farklı ark teli kombinasyonlarının sürtünme kuvveti bakımından karşılaştırılması

    A comparative of frictional resiistances in conbinations different self-ligating brackets and convantionel brackets with ortodontic archwires

    BORAGH RAHİMİ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2017

    Diş Hekimliğiİstanbul Üniversitesi

    Ortodonti Ana Bilim Dalı

    PROF. DR. GÜLNAZ MARŞAN

  3. 3D yazıcılar kullanılarak 2 farklı rezin ile üretilen braketlerin sürtünme dirençlerinin konvansiyonel braketlerle karşılaştırılması

    Comparison of frictional resistances of brackets produced by 3D printers using two different resins with conventional brackets

    AHMET YILDIRIM

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2024

    Diş HekimliğiAtatürk Üniversitesi

    Ortodonti Ana Bilim Dalı

    DOÇ. DR. ALİ KİKİ

  4. Farklı estetik braketler ve konvansiyonel braketlerlerin farklı ark telleriyle kombinasyonları sonucu oluşan sürtünme dirençlerinin ın vitro olarak karşılaştırılması

    A comparative in vitro study of frictionalresistances between different esthetic and conventional brackets and different orthodontic archwires.

    CANSU KAYA MOUSTAFA

    Doktora

    Türkçe

    Türkçe

    2021

    Diş HekimliğiBiruni Üniversitesi

    Ortodonti Ana Bilim Dalı

    PROF. DR. MUZAFFER GÜLYURT

  5. Ortodontik braketler ve ark telleri arasındaki sürtünme kuvvetlerinin deneysel olarak karşılaştırılması

    Comparative study of frictional forces between orthodontic brakets and vires

    SIDIKA ÖDÜL ONUR

    Doktora

    Türkçe

    Türkçe

    2001

    Diş HekimliğiHacettepe Üniversitesi

    Ortodonti Ana Bilim Dalı

    PROF.DR. FİLİZ YUKAY