An MR safe nitinol guidewire design for intravascular applications

İntravasküler aplikasyonlar için MR güvenli nitinol kılavuz tel tasarımı

  1. Tez No: 439761
  2. Yazar: BURCU BAŞAR
  3. Danışmanlar: YRD. DOÇ. DR. ÖZGÜR KOCATÜRK
  4. Tez Türü: Yüksek Lisans
  5. Konular: Biyomühendislik, Mühendislik Bilimleri, Bioengineering, Engineering Sciences
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2015
  8. Dil: İngilizce
  9. Üniversite: Boğaziçi Üniversitesi
  10. Enstitü: Biyomedikal Mühendislik Enstitüsü
  11. Ana Bilim Dalı: Biyomedikal Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Manyetik rezonans görüntüleme (MRG), mükemmel yumu³ak doku kontrast ve radyasyonsuz görüntüleme imkan sunar. Geleneksel k lavuz tellerde kullan lan uzun, metal malzemeler RF kaynakl s nmaya tabidir, bu nedenle MR alt nda kullan lamazlar. Bu çal ³mada, özünde MR güvenli ve mekanik performans n koruyan metal bazl k lavuz tel tasar m ve testleri anlat lmaktad r. MR güvenli k lavuz tel, duran dalga olu³umunu, dolay s yla RF kaynakl s nmay ortadan kald rmak amac yla, vücut içinde ve 1.5 T alt nda RF iletim çeyrek dalga boyundan k sa uzunlukta nitinol parçalar kullan larak in³a edilmi³tir. Elektriksel olarak yal t lan bu parçalar, k sa nitinol tüpler kullan larak birle³tirilmi³, böylece k lavuz telin çekirde§i boyunca sertlik korunmu³tur. Mekanik bütünlük ISO standartlar na göre test edilmi³tir. RF güvenli§i domuz üzerinde in vivo (1.5 T), ve ASTM standartlar na göre in vitro de§erlendirilmi³tir. Testler, prototip ve kar³ la³t r labilirlik için ticari olarak mevcut bir k lavuz tel (Glidewire, Terumo, Japonya) üzerinde yap lm ³t r. Mekanik testler, segmente çekirdekli k lavuz telin rakip ürün ile k yaslanabilirli §ini göstermi³tir. In vitro ve in vivo RF s nma deneyleri ABD G da ve laç daresi ile uyumlu olarak s nman n 2◦C'nin alt nda oldu§unu do§rulam ³t r. Bu çal ³mada, kendili§inden güvenli, pasif, metal bazl MRG k lavuz teli tasar m n n uygulanabilirli§i gösterilmi³tir. Prototip, FDA ile uyumlu olarak, yüksek sapma aç lar nda dahi önemsiz s nma (<2◦C) sergiler, ve mekanik aç dan yüksek performansl konvansiyonel metalik k lavuz teller ile k yaslanabilirdir. Bu tasar m, klinik MR kateterizasyon uygulamalar nda önemli bir ilerlemeyi temsil etmektedir.

Özet (Çeviri)

Magnetic resonance imaging (MRI) o ers excellent soft tissue contrast and radiation free imaging. Conventional guidewires employ long metallic materials for versatility and mechanical characteristics, and are subject to RF-induced heating, therefore are inappropriate for use in MR. This work describes the design and testing of a metallic guidewire that is intrinsically MR-safe with preserved mechanical performance. The MR-safe guidewire was constructed using nitinol rod segments less than a quarter wavelength of RF transmission at 1.5 T within the body to eliminate standing wave formation, hence RF heating. The insulated nitinol segments were connected by short nitinol tubes for a sti ness-matched guidewire core. Mechanical integrity was tested in vitro according to ISO standards. RF-safety was evaluated in vitro according to ASTM standards, and in vivo in swine in a 1.5T MR system. Tests were performed on the prototype and a commercially available guidewire (Glidewire, Terumo, Japan) for comparison. Mechanical tests demonstrated that the segmented-core guidewire behaves similarly to its comparator. In vitro and in vivo RF heating tests con rmed that RF heating is under 2◦C as required by US Food and Drug Administration. The feasibility of an intrinsically safe passive metallic MRI guidewire design is demonstrated. The prototype exhibits negligible heating at high ip angles in conformance with FDA guidance documents (<2◦C), yet mechanically resembles a highperformance conventional metallic guidewire. This may represent a signi cant advance once applied to clinical MRI catheterization.

Benzer Tezler

  1. Devrelerin büyük işaret cevaplarının bilgisayar yardımıyla bulunması

    Başlık çevirisi yok

    NÜKHET GÜNEYİ

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Elektrik ve Elektronik MühendisliğiUludağ Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    PROF. DR. ERGÜR TÜTÜNCÜOĞLU

  2. Ulaş Sağlık Ocağı merkezinde nüfusun bazı niteliklerine ve konutların durumuna ilişkin bir çalışma

    An Investigation carried out at the Ulaş Public Health Centre concerning some characteristics of the population and housing conditions in the district of Ulaş

    EROL ŞANLI

    Doktora

    Türkçe

    Türkçe

    1985

    Halk SağlığıCumhuriyet Üniversitesi

    Halk Sağlığı Ana Bilim Dalı

    DOÇ. DR. SERVET ÖZGÜR

  3. Diyabetus mellitus'da gözlenen mikrovasküler komplikasyonların prostaglandinler ile olan ilişkisi

    The Relation of microvaskular complications observed in diabetes mellitus with prostoglandins

    CANAN NEBİGİL

    Doktora

    Türkçe

    Türkçe

    1985

    Eczacılık ve FarmakolojiCumhuriyet Üniversitesi

    Farmakoloji Ana Bilim Dalı

    YRD. DOÇ. DR. YUSUF SARIOĞLU

  4. Pik demiri ve karbon çeliğinin sulu çözeltiler içindeki korozyon hızının tayini

    Determination of the rate of corrosion of the cast iran and carbon steel in the aqueous solutions

    EMİNE NAZAN ÜNAL

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Kimya MühendisliğiGazi Üniversitesi

    Kimya Mühendisliği Ana Bilim Dalı

    DOÇ. DR. HAYRİ YALÇIN