Geri Dön

Farklı adeziv uygulama teknikleri ile ara yüzey degradasyonunun bağlanma dayanımına etkisinin in vitro incelenmesi

In vitro evaluation of the adhesive interface degradation on bond strength with different adhesive applications

  1. Tez No: 433264
  2. Yazar: GÜLŞAH YENİER
  3. Danışmanlar: PROF. DR. BERNA TARIM
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Basitleştirilmiş adeziv sistem, Adeziv uygulama, Adeziv ara yüzey degradasyonu, suda bekletme, Mikrogerilim bağlanma dayanımı, Adezyonlar, Biyolojik parçalanma, Dental bonding, Dentin, Yapay yaşlandırma, Simplified adhesive systems, Adhesive application, Adhesive interface degradation, Water storage, Microtensile bond strength, Adhesions, Biodegradation, Dental bonding, Dentin, Artificial aging
  7. Yıl: 2015
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Diş Hastalıkları ve Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı; basitleştirilmiş adeziv sistemlerde adeziv ara yüzey degradasyonunu azaltmak amaçlı %2 Klorheksidin (CHX) uygulaması, adezivin iki kat olarak uygulanması (x2K) ve ilave hidrofobik reçine (HR) uygulamasının dentine olan mikrogerilim bağlanma dayanımına etkisini araştırmaktır. Çalışmamızda kontrol grubunu Clearfil SE Bond (SE), deney gruplarını Adper Single Bond 2 (SB), Clearfil S3 Bond (S3) adezivleri oluşturmuştur. Sağlam 72 adet üçüncü büyük azı dişin yarısı 24 saat, kalan yarısı 6 ay sonraki bağlanma dayanımının ölçülmesinde kullanılmıştır. Düz koronal dentin yüzeylerinde 600 grit silikon karbit kağıtla 60 sn. smear tabakası oluşturularak dişler 9 gruba ayrılmıştır (n=4): SE-Kontrol, SB-Kontrol, S3-Kontrol, SB-CHX, SB-x2K, SB-HR, S3-CHX, S3-x2K, S3-HR. Kompozit bloklar (3M ESPE) tabakalama yöntemiyle oluşturularak (5 mm) 37°C distile suda bekletilmiştir. Kesitlere ayrılarak (Isomet) her bir çubuk kesit (1 mm2) hemen ve 6 ay 37°C suda bekletildikten sonra çapraz kafa hızı 0,5 mm/dk. ile mikrogerilim test aygıtına (Bisco) yerleştirilmiştir. Elde edilen veriler istatistiksel olarak Three-way ANOVA, Tukey HDS testleriyle değerlendirilmiştir (p<0,05). Çalışmamızda tüm grupların 6 ay sonraki bağlanma değerlerinde anlamlı düzeyde azalma saptanmıştır (p<0,01). Kontrol grubu SE adezivi istatistiksel olarak en yüksek bağlanma değerini gösterirken (p<0,01) SB-Kontrol ve S3-Kontrol arasında anlamlı farklılık bulunmamaktadır (p>0,05). CHX, x2K ve HR uygulamaları bağlanma dayanımını arttırırken anlamlı farklılık x2K ve HR uygulamalarında tespit edilmiştir (p<0,01) ve en yüksek bağlanma değerini HR uygulaması göstermiştir (p<0,01). Adeziv sistemlerin bağlanma değerleri karşılaştırıldığında sadece x2K ve HR uygulaması S3 adezivinde anlamlı düzeyde yüksektir (p<0,01). x2K ve HR uygulamaları reçine-dentin bağlanma dayanımını anlamlı düzeyde arttırmakta ve adeziv ara yüzey degradasyonunu azaltmaktadır.

Özet (Çeviri)

The purpose of this study was to evaluate the influence of 2% Chlorhexidine (CHX), double adhesive layer (x2K), extra hybrophobic resin (HR) applications proposed to decrease adhesive interface degradation on the microtensile dentin bond strength of simplified adhesive systems. Clearfil SE Bond (SE) was used as control, Adper Single Bond2 (SB) and Clearfil S3 Bond (S3) were tested. The half of 72 sound human molar teeth used for immediate bond strength, other half of teeth for 6 month. Smear layer was created with 600-grit silicon-carbide paper for 60 s on coronal dentin surface. Teeth were divided into 9 groups (n=4): SE-Control, SB-Control, S3-Control, SB-CHX, SB-x2K, SB-HR, S3-CHX, S3-x2K, S3-HR. Composite blocks (3M ESPE) were incrementally built up (5 mm), stored in distilled water at 37°C. They were sectioned (Isomet), each stick (1 mm2) was attached to MicroTensile Tester (Bisco) immediately and 6 month water storage at crosshead speed 0.5 mm/min. The data were statistically analyzed by Three-way ANOVA, Tukey HDS (p<0.05). After 6 month, all groups bond strength reduced significantly (p<0.01). SE showed the highest bond strength while no difference was found between SB-Control and S3-Control (p>0.05). Higher bond strengths values were observed for CHX, x2K and HR applications, however HR and x2K were significantly different from control group (p<0.01) and HR bond strength was the highest (p<0.01). When compared the adhesives only x2K and HR application for S3 was significantly higher (p<0.01). The application of x2K and HR can improve the resin-dentin bonds and decrease the adhesive interface degradation.

Benzer Tezler

  1. Dentin dokusuna farklı hazırlık yöntemleri ve uygulama teknikleri ile“universal adeziv”bağlayıcıların bağlanma dayanıklılığına etkisi

    The effect of different application strategies on the durability of dentin bond strength of different universal adhesive systems

    ASHRAF RADAYDA

    Doktora

    Türkçe

    Türkçe

    2016

    Diş Hekimliğiİstanbul Üniversitesi

    Diş Hastalıkları ve Tedavisi Ana Bilim Dalı

    PROF. DR. TAHİR SAMİ BÜYÜKGÖKÇESU

  2. İki farklı rezin içerikli pit ve fissür örtücünün farklı modlarda adeziv sistem ile uygulanmasının mikrosızıntı üzerine etkisi

    In Vitro evaluation of microleakage in two resin-based pit and fissure sealants applied with a universal adhesive in different etching modes

    ECEM CÖMERT

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2025

    Diş HekimliğiKütahya Sağlık Bilimleri Üniversitesi

    Pedodonti Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ BEYZA ECEM ALKAÇ EKİCİ

  3. Farklı uygulama tekniklerinin self-ETCH modunda kullanılan universal adezivlerin dentindeki mikrogerilme bağlanma dayanımına etkisinin araştırılması

    Evaluation of the effects of different application techniques on the dentin microtensile bond strength of universal adhesives used in self ETCHmode

    MUHİTTİN UĞURLU

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2016

    Diş HekimliğiSüleyman Demirel Üniversitesi

    Restoratif Diş Tedavisi ve Endodonti Ana Bilim Dalı

    PROF. DR. RABİA BANU ERMİŞ

  4. Dentin yüzeyine uygulanan farklı deproteinize edici enzimlerin makaslama bağlanma dayanımı ve mikrosızıntı üzerine etkilerinin incelenmesi: In vitro çalışma

    Investigation of the effects of different deproteinizing enzymes applied on the dentin surface on shear bond strength and microleakage: An in vitro study

    FATİH BEDİR

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2021

    Diş HekimliğiRecep Tayyip Erdoğan Üniversitesi

    Restoratif Diş Tedavisi Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ GÜL YILDIZ TELATAR

  5. Aşırı kron harabiyetine sahip üst ön keser dişlerin direkt ve indirekt restorasyon sonrası kırılma dayanımlarının karşılaştırılması

    Comparison of the fracture strength of the maxillary central incisor teeth with extensive crown damaged after direct and indirect restoration

    YAKUP BOZ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2022

    Diş HekimliğiAnkara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. SADULLAH ÜÇTAŞLI