Geri Dön

Farklı çaplardaki titanyum, zirkonyum ve titanyum-zirkonyum alaşımlı implantlarda ve çevreleyen kemik dokusunda oluşan streslerin üç boyutlu sonlu elemanlar stres analizi yöntemi ile karşılaştırılması

Analyzing the stresses on different diameters of titanium, zirconium and titanium-zirconium alloy implants and supported bone tissues BY three dimensional finite element analysis method

  1. Tez No: 431862
  2. Yazar: ZÜBEYDE ÖZLEM ZEREN
  3. Danışmanlar: PROF. DR. SEDAT HAKAN TERZİOĞLU
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: dental implant, SESA, titanyum, titanyum-zirkonyum alaşımı, üç boyutlu sonlu elemanlar stres analizi yöntemi, zirkonyum, Dental implantasyon, Dental implantlar, Dental stres analizi, Diş hekimleri, Kemik ve kemikler, Sonlu elemanlar stres analizi, Çene, dental implant, FEM, Three Dimensional Finite Element Analysis Method, titanium, titanium-zirconium alloy, zirconium, Dental implantation, Dental implants, Dental stress analysis, Dentists, Bone and bones, Finite elements stress analysis, Jaw
  7. Yıl: 2016
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Günümüzde kaybedilen dişlerin restorasyonunda dental implantlar sıklıkla kullanılmaktadır. Dental implant materyali olarak titanyum yaygın olarak kullanılmakla beraber titanyuma alternatif materyal arayışları devam etmektedir. Titanyum implantlarda ortaya çıkabilen estetik sakıncalar zirkonyum implantların kullanımını gündeme getirirken, dar çaplı implantlarda titanyumun yorulma ve kırılma dayanımının yetersiz kalması Ti-Zr alaşımı implant materyalinin geliştirilmesini sağlamıştır. Kullanılan implant materyalinin özelliklerinin iyi bilinmesi ve biyomekanik prensiplerinin doğru uygulanması, implant tedavilerinin başarısı açısından önemlidir. Çalışmamızın amacı; titanyuma alternatif olarak gösterilen Zr ve Ti-Zr alaşımı implantlar kullanıldığında, implantlarda ve çevreleyen kemik dokusunda oluşan streslerin implantların çap değişimlerine göre nasıl değiştiğinin 3 boyutlu sonlu elemanlar stres analiz yöntemi ile değerlendirmektir. Çalışmamızda 3 farklı implant materyalinden (titanyum, zirkonyum, titanyum-zirkonyum alaşımı) implant uzunluğu sabit tutulmak koşuluyla, en ince 3,00 mm en kalın 5,00 mm olmak üzere değişen çaplarda modeller oluşturulmuştur. Çap artışı, her bir materyal için 3,00 mm'den başlanarak 0,1 mm arttırılarak 5,00 mm'ye kadar devam ettirilmiştir. Her materyal için 21'er adet implant modeli oluşturulmuştur. Her bir modele oblik yönde (45°) 100 N kuvvet ayrı ayrı uygulanarak toplam 63 çalışma modeli elde edilmiştir. Uygulanan kuvvetler sonucunda trabeküler ve kortikal kemikte oluşan maksimum ve minimum asal gerilme değerlerine ve implantlarda ve abutment vidasında oluşan von Mises gerilme değerlerine implant çap değişiminin ve implant materyal özelliklerinin etkisi incelenmiştir. Bu çalışmanın sınırları içerisinde elde edilen sayısal değerler, implant çapının ve üretildiği materyalin kuvvet iletimini etkilediğini ve değiştirdiğini göstermiştir. İmplant çapındaki artış her üç implant materyali için de stres miktarlarının azalmasına ve stres alanlarının daralmasına sebep olmuştur. Zirkonyum implantlar titanyum ve Ti-Zr implantlara göre daha yüksek elastisite modülüne sahip olduklarından, implant çevresindeki kemikte daha düşük stresler oluşturmaktadır. Dar çaplarda implant materyallerinin kemiğe ilettikleri stres farklılıkları oldukça belirginken, çap artışıyla bu fark azalmaktadır. Ti-Zr implantlar dar çaplarda Ti ve Zr implantlara göre daha iyi performans sergilemektedir.

Özet (Çeviri)

Today, dental implant materials are often used in the restoration of missing teeth. In spite of the fact that titanium as a dental implant material is commonly used, there are still alternative material searches for titanium. Because of esthetics disadvantages occured in titanium implants bring forward the use of zirconium implants. Inadequacy of fatigue and fracture strength properties of titanium in narrow diameter implants, has ensured Ti-Zr alloy implant material to be improved. Knowledge of properties of the implant material and correct application of biomechanics are vital in terms of the success of implant treatments. The aim of our study is to evaluate how the stresses in implants and supporting bone tissue has changed according to changes in implant diameters, when Zr and Ti-Zr alloy implants, which are considered to be alternatives for titanium, are used by three dimensional finite element analysis method. In this study three different implant materials (titanium, zirconium, titanium-zirconium alloy) were used and 21 models were created from each material at different diameters from 3,00 mm to 5,00 mm by 0,1 mm incrementals. The length of the implants were kept constant. Totally 63 study models were modelled and 100 N force was applied for each model in oblique (45°) direction. The effect of implant diameter and material differences on cortical-trabecular bones, implant and the abutment screws were evaluated by analyizing max-minimum principle and Von Misses stresses. Within the limits of this study, it was determined that implant diameter and material changes affected the force distribution. Increase of implant diameter caused to decrease of stress quantities and distribution for each three implant materials. Zirconium caused lower stresses in implant supporting bone tissues, as it had higher elasticity modulus than Ti and Ti-Zr alloy. While stress transfer of all implant materials in narrow diameters to bone differed significantly, this difference decreased in wider diameters. In narrow diameters, Ti-Zr implants gave better performance than Ti and Zr implants.

Benzer Tezler

  1. Tam dişsiz mandibulanın eğimli implantlarla rehabilitasyonunda farklı tip ve çaplardaki implantların ve farklı protetik alt yapı materyallerinin stres dağılımına etkisinin sonlu elemanlar analizi ile incelenmesi

    Observation of the effect of different material and diameters of implants anddifferent framework materials on stress distribution i̇n rehabilitation of fulledentulous mandible with tilted implants by finite element analysis

    AYŞE UYSAL

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2019

    Diş HekimliğiTokat Gaziosmanpaşa Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ YELİZ HAYRAN

  2. Farklı implant ve alt yapı materyalleri kullanımının stres dağılımına etkisinin sonlu elemanlar stres analizi yöntemi ile değerlendirilmesi

    Influences of different implant and framework materials on stress distribution by three dimensional finite element analysis method

    GÜLCAN BAHADIRLI

    Doktora

    Türkçe

    Türkçe

    2017

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. DENİZ ŞEN

  3. Buğdayda farklı melezleme teknikleri kullanarak tohum tutma oranının saptanılması

    Başlık çevirisi yok

    İSMAİL TÜZÜN

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    ZiraatUludağ Üniversitesi

    Tarla Bitkileri Ana Bilim Dalı

    PROF. DR. HALİS RUHİ EKİNGEN

  4. Diyabetus mellitus'da gözlenen mikrovasküler komplikasyonların prostaglandinler ile olan ilişkisi

    The Relation of microvaskular complications observed in diabetes mellitus with prostoglandins

    CANAN NEBİGİL

    Doktora

    Türkçe

    Türkçe

    1985

    Eczacılık ve FarmakolojiCumhuriyet Üniversitesi

    Farmakoloji Ana Bilim Dalı

    YRD. DOÇ. DR. YUSUF SARIOĞLU