Geri Dön

Mastektomi sonrası radyoterapi uygulamalarında alan-içinde-alan (FiF), yoğunluk ayarlı radyoterapi (IMRT) ve volumetrik ayarlı ark terapi (VMAT) tedavi yöntemlerinin karşılaştırılması

Comparison of field-in-field (FiF), intensity modulated radiation therapy (IMRT) and volumetric arc radiation therapy (VMAT) treatment techniques for post-mastectomy radiotherapy

  1. Tez No: 424657
  2. Yazar: HÜLYA ÖZDEMİR
  3. Danışmanlar: PROF. DR. MELEK NUR YAVUZ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Onkoloji, Fizik ve Fizik Mühendisliği, Oncology, Physics and Physics Engineering
  6. Anahtar Kelimeler: Mastektomi, Meme neoplazmları, Neoplazmlar, Radyasyon, Radyasyon dozajı, Radyasyon etkileri, Radyoterapi, Tedavi, Mastectomy, Breast neoplasms, Neoplasms, Radiation, Radiation dosage, Radiation effects, Radiotherapy, Treatment
  7. Yıl: 2015
  8. Dil: Türkçe
  9. Üniversite: Akdeniz Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Radyasyon Onkolojisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Mastektomi sonrası radyoterapi (PMRT) uygulamalarında Alan-içinde-Alan (FiF), Yoğunluk Ayarlı Radyoterapi (IMRT) ve Volumetrik Ayarlı Ark Terapi (VMAT) tedavi yöntemlerinin karşılaştırılması amaçlanmıştır. Metod: On yedi sol mastektomi hastasına ait CT görüntüleri alınıp hedef ve kritik yapılar çizilmiştir. Bu hastaların tedavileri, FiF (XIO tedavi planlama sisteminde), IMRT ve VMAT teknikleriyle (MONACO planlama sisteminde) planlanmıştır. Planlarda PTV (Göğüs duvarı), Lenf Nodları (LN), Aksilla (AX), Supra klavikular bölge (SCF) ve Mamaria interna lenf nodu (IMN), akciğer (bilateral, sol ve sağ), kalp ve karşı meme dozları değerlendirilmiştir. FiF planlarında karşılıklı tanjansiyel alanlar (maksimum 3 segment) kullanılırken SCF ve LN dozlarını tamamlayabilmek için tek merkezli half beam modeli baz alınmıştır. IMRT planlarında iç ve dış alanların açılarına ±15 derece uygulanmıştır. VMAT planlarında 60 derecelik tanjansiyel 2 ark olacak şekilde planlar oluşturulmuştur. Sonuç: Tüm tedavi yöntemleri klinik olarak uygulanabilirdir. Yapılan analizler sonucunda da verilerin normal dağılıma uygun olduğu görülmüştür. Hedef hacimler için tüm tekniklerde (p>0.05) kabul edilebilir sonuçlar elde edilirken, kritik hacimler bakımından tVMAT ve IMRT planları, FiF planlarına göre daha iyi sonuçlar vermiştir. Tanjansitel VMAT (tVMAT) ve IMRT planlarında V20Gy alan sol akciğer yüzdesi FiF planına göre %31.0 ve %28.5 azalmıştır. FiF ile tVMAT ve IMRT planları arasında sol akciğer açısından fark bulunmaktadır (p<0.05). tVMAT ve IMRT planlarında Kalp için mean doz değerinde FiF tekniğine göre sırasıyla %32.4 ve %33.8 azalma görülmüştür. Kalp dozları açısından planlar değerlendirildiğinde istatistiksel olarak IMRT ve FiF planları arasında anlamlı farklılıklar görülmektedir (p<0.05).Ancak tVMAT arasında farklılık yoktur (p>0.05). Karşı meme maksimum dozları dikkate alındığında FiF ve tVMAT planları arasında farklılıklar görülmektedir (p<0.05). Tartışma: Hedef hacimler açısından karşılaştırıldığında FiF, IMRT ve tVMAT teknikleri kabul limitleri içindedir ve klinik olarak uygulanabilirdir. Ancak bizim çalışmamız gösterdi ki kritik hacimler söz konusu olduğunda özellikle kalp ve akciğer dozları için tVMAT tekniği hem IMRT hem de FiF tekniğine göre daha başarılı sonuçlar vermektedir. Ancak karşı meme açısından IMRT ve FiF tekniği tercih edilebilirdir. Bu tekniklerin uygulanabilir olmasında hastaların anatomik yapıları, sabitleme pozisyonları ve fiziksel özellikleri gibi parametreler de dikkate alınmalıdır.

Özet (Çeviri)

Purpose: To investigate the feasibility of Field-in-Field (FiF), Intensity Modulated Radiotherapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT) for Postmastectomy Radiotherapy (PMRT) and compare tangential VMAT treatment plans to IMRT and FiF plans. Methods: FiF, IMRT and tVMAT treatment plans were created for seventeen PMRT patients previously treated at our clinic. XIO treatment planning systems was used for FiF treatment plans and MONACO Planning systems was used for IMRT, tVMAT treatment plans. Planning target volumes (PTV) included the chest wall. Lenf nodes, axilla, supra clavicular fossa, ipsilateral, contralateral and total lungs, heart and contralateral breast doses was evaluated. The following metrics were used to compare treatment plans for each patient. FiF plans were generated tangential field and clavicular and axilla field, IMRT plans consisting of 6 beams of about tangential beam, ±150 adding beam and a VMAT plans consisting of 2 small tangential arc segments of about 600. Results: All treatment methods clinically can be accepted PMRT plans. As a results of statistical analyzes, all of data have the normal dispersion. While all techniques are occurred acceptable results for target volumes, tVMAT and IMRT plans showed better for critical volumes to compared the FiF plans. tVMAT and IMRT plans showed a 31.0% and 28.5% decrease in V20Gy in the left lung to compared the FiF plans (p<0.05). tVMAT and IMRT plans showed a 32.4% and 33.8% decrease in mean doses of heart compared to FiF plans. Heart doses evaluated in terms of the plans shows significant differences between IMRT and FIF plans statistically. However, tVMAT plans have not been differences compared with FiF and IMRT. When examined the maximum doses of contralateral breast are differences between FiF and tVMAT plans (p<0.05). Conclusion: FiF, IMRT and tVMAT provide acceptable treatment plans for target volumes and these plans can be delivered in clinical procedures. However Our study showed that tVMAT technique gives better results according to both IMRT and FiF techniques when the ciritical volumes are concerned particularly for heart and lung doses. So that, the parameters like anatomical structure, immobilization and physical specification of the patients should also be taken in consideration to perform these planning techniquies.

Benzer Tezler

  1. Meme kanseri cerrahisi sonrası radyoterapi döneminde egzersiz uygulamalarının sanal gerçeklik temelli egzersiz eğitimi ile karşılaştırılması

    Comparison of exercise practices with virtual reality-based exercise training in radiotherapy period after breast cancer surgery

    İLKNUR ONURLU

    Doktora

    Türkçe

    Türkçe

    2020

    Fiziksel Tıp ve RehabilitasyonGazi Üniversitesi

    Fizyoterapi ve Rehabilitasyon Ana Bilim Dalı

    DOÇ. DR. İLKE KESER

  2. Opere meme kanserli kadın hastalarda omuz disabilitesine yönelik fizik tedavi modaliteleri ve egzersiz ile sadece egzersiz tedavisinin etkilerinin karşılaştırılması

    Comparison of effect of exercise alone to that of exercise plus physical therapy modalities on shoulder disabilty in female patients with operated breast cancer

    MAHMUT SAKALLI

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2013

    Fiziksel Tıp ve RehabilitasyonCelal Bayar Üniversitesi

    Fiziksel Tıp ve Rehabilitasyon Ana Bilim Dalı

    PROF. DR. CANAN TIKIZ

  3. Mastektomi sonrası radyoterapi yapılmış hastalarda lokal nüks oranları ve buna etki eden faktörler

    Başlık çevirisi yok

    EMRE MERDAN FAYDA

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2002

    Onkolojiİstanbul Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF.DR. MAKTAV DİNÇER

  4. Mastektomi sonrası radyoterapi uygulanan sol meme kanserli hastalarda alan içinde alan (FIF), volümetrik ayarlı ark terapi (VMAT) ve yoğunluk ayarlı radyoterapi (IMRT) yöntemlerinin değerlendirilmesi

    Evaluation of field in field (FIF), volumetric modulated ARC therapy (VMAT) and intensity modulated radiotherapy (IMRT) methods in left breast cancer patients received radiotherapy after mastectomy

    NURGÜL GÜLMEZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    Fizik ve Fizik Mühendisliğiİstanbul Aydın Üniversitesi

    Sağlık Fiziği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ KAMİL TEMİZYÜREK