Değişik tekniklerle elde edilen metal seramik altyapılarda porselen fırınlama aşamaları sonrasında marjinal uyumlarında meydana gelen değişikliklerinin in vitro olarak incelenmesi
In vitro evaluation of marginal adaptation of metal ceramic copings fabricated by different techniques after porcelain firing stages
- Tez No: 414905
- Danışmanlar: DOÇ. DR. ŞEBNEM BEGÜM TÜRKER
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Dental materyaller, Dental porselen, Dental restorasyon, Lazerler, Metal alaşımlar, Sinterleme, Takma diş tabanları, Dental materials, Dental porcelain, Dental restoration, Lasers, Metal alloys, Sintering, Denture bases
- Yıl: 2015
- Dil: Türkçe
- Üniversite: Marmara Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Değişik metal altyapı teknikleriyle elde edilen metal seramik üç ve dört üyeli sabit köprü restorasyonlarının, porselen fırınlama öncesi ve sonrası marjinal uyumlarında meydana gelen değişikliklerin karşılaştırılmasıdır. Gereç ve Yöntem: Kesilmiş küçük azı ve büyük azı dişlerini taklit edecek şekilde paslanmaz çelik alaşımdan 30'ar adet üç ve dört üyeli toplam 60 adet köprü modeli hazırlandı. Örnekler; her grupta 10'ar adet üç ve dört üyeli köprü olacak şekilde rastgele üç gruba ayrıldı ve lazer sinterleme (LS) (Eosint M 270, EOS, Almanya), CAD/CAM metal frezeleme (MF) (Yenamak D 40, Yenadent, Türkiye) ve konvansiyonel mum uçurma tekniği (KM) ile metal altyapılar üretildi. Metal altyapılar paslanmaz çelik modellere yerleştirildi. Porselen fırınlama öncesinde ve sonrasında elde edilen silikon replikalardan kesitler elde edilerek restorasyonların marjinal uyum değerleri ışık mikroskobu (Leica Cambridge, Cambridge, İngiltere) ile ölçüldü. İstatistiksel analiz için Mann-Whitney U testi, Kruskal Wallis testi ve normal dağılım göstermeyen parametrelerin gruplar içi karşılaştırılmasında Wilcoxon işaret testleri kullanıldı. Sonuçlar % 95 güven aralığında, p<0,05 düzeyinde değerlendirildi. Bulgular: Ortalama marjinal aralık değerleri, porselen fırınlama öncesinde; üç üyeli köprülerde KM: 98,68 µm, MF: 82,74 µm ve LS: 63,97 µm, dört üyeli köprülerde; KM: 68,72 µm, MF: 71,70 µm ve LS: 70,42 µm, porselen fırınlama sonrasında; üç üyeli köprülerde KM: 64,58 µm, MF: 63,69 µm ve LS: 64,27 µm, dört üyeli köprülerde KM: 65,70 µm, MF: 61,95 µm ve LS: 71,64 µm bulunmuştur. Sonuçlar: Test edilen üç ve dört üyeli metal altyapılarda porselen fırınlama sonrasında genel olarak marjinal aralık değerlerinde azalma saptanmıştır.
Özet (Çeviri)
Purpose: Comparison of marginal fit changes between three- and four-units metal ceramic fixed partial dentures fabricated by three different metal framework techniques before and after veneering. Material and method: A total of 60 three- and four- unit fixed partial dentures model representing prepared premolar and molar teeth were fabricated from stainless steel. Samples were randomly divided into three groups to fabricate metal ceramic fixed partial denture frameworks with laser sintering (LS) (Eosint M 270, EOS, Munich, Germany), CAD/CAM milling (CM) (Yenamak D 40, Yenadent, Istanbul, Turkey) and conventional lost wax (LW) techniques. Metal frameworks were put on stainless steel models. Before and after porcelain firing, cross-sections from silicone replicas were examined and measured with a light microscope (Leica Cambridge, Cambridge, England). For statistical analysis, Mann-Whitney U test, Kruskal Wallis test were used, Wilcoxon Signed Ranks test was used for comparison of parameters which were not normally distributed in the groups. Results were evaluated at 95 % confidence interval and p<0,05 level. Results: Mean marginal gap values were obtained as follows: before porcelain firing cycles; in three-unit bridges LW: 98,68 µm, CM: 82,74 µm and LS: 63,97 µm, in four-unit bridges LW: 68,72 µm, CM: 71,70 µm and LS: 70,42 µm, after porcelain firing cycles; in three-unit bridges LW: 64,58 µm, CM: 63,69 µm and LS: 64,27 µm, in four-unit bridges LW: 65,70 µm, CM: 61,95 µm and LS: 71,64 µm. Conclusion: In general, three- and four-unit metal frameworks showed decrease in marginal gap values after porcelain firing cycles.
Benzer Tezler
- Farklı pH ortamlarında zirkonya seramiklerinin sertlik ve kırılma mukavemetinin mikroyapı analizi ile incelenmesi
The evaluation of hardness and fracture toughness of zirconia ceramics stored in environments with different pH values using microstructural analysis
VOLKAN TURP
Doktora
Türkçe
2010
Diş Hekimliğiİstanbul ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. BETÜL TUNCELLİ
- Selektif lazer sinterizasyon ve döküm yöntemleri ile elde edilen metal altyapıların lehiminde kullanılan farklı tekniklerin mekanik özelliklerinin, elemental içeriğinin ve mikroyapısının değerlendirilmesi
The evaluation of mechanical properties, elemental composition and microstructure of different soldering techniques conducted on selective laser sintering and conventional cast metal substructures
ECMEL NADİR BUDAK
Doktora
Türkçe
2015
Diş HekimliğiÇukurova ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. YURDANUR UÇAR
- Fabrıcatıon of 3D prınted flexıble polyurethane nanocomposıte
3b baskili esnek poliüretan nanokompozit imalati
ALİCAN MERT
Yüksek Lisans
İngilizce
2025
Polimer Bilim ve Teknolojisiİstanbul Teknik ÜniversitesiNanobilim ve Nanomühendislik Ana Bilim Dalı
DOÇ. DR. BİRGÜL BENLİ
- Seramik boyalarının üretiminde uygulanan teknikler ve bunların boya özelliklerinin üzerindeki etkileri
Başlık çevirisi yok
YUSUF YILDIZ
- Metal matrisli kompozitlerin kam malzemesi olarak kullanılabilirliğinin araştırılması
An investigation on usability of metal matrix composites as a camshaft material
AFŞIN ALPER CERİT
Doktora
Türkçe
2010
Makine MühendisliğiErciyes ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
PROF. DR. MEHMET BAKİ KARAMIŞ