Geri Dön

Değişik tekniklerle elde edilen metal seramik altyapılarda porselen fırınlama aşamaları sonrasında marjinal uyumlarında meydana gelen değişikliklerinin in vitro olarak incelenmesi

In vitro evaluation of marginal adaptation of metal ceramic copings fabricated by different techniques after porcelain firing stages

  1. Tez No: 414905
  2. Yazar: MUHAMMED ABDULLAH KELEŞ
  3. Danışmanlar: DOÇ. DR. ŞEBNEM BEGÜM TÜRKER
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Dental materyaller, Dental porselen, Dental restorasyon, Lazerler, Metal alaşımlar, Sinterleme, Takma diş tabanları, Dental materials, Dental porcelain, Dental restoration, Lasers, Metal alloys, Sintering, Denture bases
  7. Yıl: 2015
  8. Dil: Türkçe
  9. Üniversite: Marmara Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Değişik metal altyapı teknikleriyle elde edilen metal seramik üç ve dört üyeli sabit köprü restorasyonlarının, porselen fırınlama öncesi ve sonrası marjinal uyumlarında meydana gelen değişikliklerin karşılaştırılmasıdır. Gereç ve Yöntem: Kesilmiş küçük azı ve büyük azı dişlerini taklit edecek şekilde paslanmaz çelik alaşımdan 30'ar adet üç ve dört üyeli toplam 60 adet köprü modeli hazırlandı. Örnekler; her grupta 10'ar adet üç ve dört üyeli köprü olacak şekilde rastgele üç gruba ayrıldı ve lazer sinterleme (LS) (Eosint M 270, EOS, Almanya), CAD/CAM metal frezeleme (MF) (Yenamak D 40, Yenadent, Türkiye) ve konvansiyonel mum uçurma tekniği (KM) ile metal altyapılar üretildi. Metal altyapılar paslanmaz çelik modellere yerleştirildi. Porselen fırınlama öncesinde ve sonrasında elde edilen silikon replikalardan kesitler elde edilerek restorasyonların marjinal uyum değerleri ışık mikroskobu (Leica Cambridge, Cambridge, İngiltere) ile ölçüldü. İstatistiksel analiz için Mann-Whitney U testi, Kruskal Wallis testi ve normal dağılım göstermeyen parametrelerin gruplar içi karşılaştırılmasında Wilcoxon işaret testleri kullanıldı. Sonuçlar % 95 güven aralığında, p<0,05 düzeyinde değerlendirildi. Bulgular: Ortalama marjinal aralık değerleri, porselen fırınlama öncesinde; üç üyeli köprülerde KM: 98,68 µm, MF: 82,74 µm ve LS: 63,97 µm, dört üyeli köprülerde; KM: 68,72 µm, MF: 71,70 µm ve LS: 70,42 µm, porselen fırınlama sonrasında; üç üyeli köprülerde KM: 64,58 µm, MF: 63,69 µm ve LS: 64,27 µm, dört üyeli köprülerde KM: 65,70 µm, MF: 61,95 µm ve LS: 71,64 µm bulunmuştur. Sonuçlar: Test edilen üç ve dört üyeli metal altyapılarda porselen fırınlama sonrasında genel olarak marjinal aralık değerlerinde azalma saptanmıştır.

Özet (Çeviri)

Purpose: Comparison of marginal fit changes between three- and four-units metal ceramic fixed partial dentures fabricated by three different metal framework techniques before and after veneering. Material and method: A total of 60 three- and four- unit fixed partial dentures model representing prepared premolar and molar teeth were fabricated from stainless steel. Samples were randomly divided into three groups to fabricate metal ceramic fixed partial denture frameworks with laser sintering (LS) (Eosint M 270, EOS, Munich, Germany), CAD/CAM milling (CM) (Yenamak D 40, Yenadent, Istanbul, Turkey) and conventional lost wax (LW) techniques. Metal frameworks were put on stainless steel models. Before and after porcelain firing, cross-sections from silicone replicas were examined and measured with a light microscope (Leica Cambridge, Cambridge, England). For statistical analysis, Mann-Whitney U test, Kruskal Wallis test were used, Wilcoxon Signed Ranks test was used for comparison of parameters which were not normally distributed in the groups. Results were evaluated at 95 % confidence interval and p<0,05 level. Results: Mean marginal gap values were obtained as follows: before porcelain firing cycles; in three-unit bridges LW: 98,68 µm, CM: 82,74 µm and LS: 63,97 µm, in four-unit bridges LW: 68,72 µm, CM: 71,70 µm and LS: 70,42 µm, after porcelain firing cycles; in three-unit bridges LW: 64,58 µm, CM: 63,69 µm and LS: 64,27 µm, in four-unit bridges LW: 65,70 µm, CM: 61,95 µm and LS: 71,64 µm. Conclusion: In general, three- and four-unit metal frameworks showed decrease in marginal gap values after porcelain firing cycles.

Benzer Tezler

  1. Farklı pH ortamlarında zirkonya seramiklerinin sertlik ve kırılma mukavemetinin mikroyapı analizi ile incelenmesi

    The evaluation of hardness and fracture toughness of zirconia ceramics stored in environments with different pH values using microstructural analysis

    VOLKAN TURP

    Doktora

    Türkçe

    Türkçe

    2010

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. BETÜL TUNCELLİ

  2. Selektif lazer sinterizasyon ve döküm yöntemleri ile elde edilen metal altyapıların lehiminde kullanılan farklı tekniklerin mekanik özelliklerinin, elemental içeriğinin ve mikroyapısının değerlendirilmesi

    The evaluation of mechanical properties, elemental composition and microstructure of different soldering techniques conducted on selective laser sintering and conventional cast metal substructures

    ECMEL NADİR BUDAK

    Doktora

    Türkçe

    Türkçe

    2015

    Diş HekimliğiÇukurova Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. YURDANUR UÇAR

  3. Fabrıcatıon of 3D prınted flexıble polyurethane nanocomposıte

    3b baskili esnek poliüretan nanokompozit imalati

    ALİCAN MERT

    Yüksek Lisans

    İngilizce

    İngilizce

    2025

    Polimer Bilim ve Teknolojisiİstanbul Teknik Üniversitesi

    Nanobilim ve Nanomühendislik Ana Bilim Dalı

    DOÇ. DR. BİRGÜL BENLİ

  4. Seramik boyalarının üretiminde uygulanan teknikler ve bunların boya özelliklerinin üzerindeki etkileri

    Başlık çevirisi yok

    YUSUF YILDIZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1993

    KimyaMarmara Üniversitesi

    Analitik Kimya Ana Bilim Dalı

    PROF.DR. ATEŞ ARCASOY

  5. Metal matrisli kompozitlerin kam malzemesi olarak kullanılabilirliğinin araştırılması

    An investigation on usability of metal matrix composites as a camshaft material

    AFŞIN ALPER CERİT

    Doktora

    Türkçe

    Türkçe

    2010

    Makine MühendisliğiErciyes Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. MEHMET BAKİ KARAMIŞ