Bilgisayarlı tomografi doz indeksi dozimetrik ölçümlerinin Monte Carlo simülasyonu ile karşılaştırılması
Comparison of measurements of computed tomography dose index (CTDI) with Monte Carlo simulation
- Tez No: 408508
- Danışmanlar: PROF. DR. EMEL ADA, YRD. DOÇ. DR. KADİR AKGÜNGÖR
- Tez Türü: Yüksek Lisans
- Konular: Fizik ve Fizik Mühendisliği, Radyoloji ve Nükleer Tıp, Physics and Physics Engineering, Radiology and Nuclear Medicine
- Anahtar Kelimeler: Bilgisayarlı Tomografi, GAMOS, Monte Carlo Simülasyonu, CTDI, Radyasyon Dozu, Monte Carlo benzetimi, Computed Tomography, GAMOS, Monte Carlo Simulation, CTDI, Radiation Dose
- Yıl: 2014
- Dil: Türkçe
- Üniversite: Dokuz Eylül Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
AMAÇ : Bu çalı¸smanın amacı, bilgisayarlı tomografi doz indeksi (CTDI) verilerinin Monte Carlo hesaplama tekniğiyle elde edilebilmesi ve deneysel sonuçlarla karşılaştırılmasıdır. GEREÇ ve YÖNTEM : Bu çalışma deney ve teorik olmak üzere ikiye ayrılmıştır. Deney kısmında katıhal dedektör ve film dozimetre kullanılarak absorbe radyasyon dozu ölçümleri yapılmıştır. CTDI ölçümleri dedektör ile vücut ve baş fantomu kullanılarak gerçekleştirilmiştir. Teorik kısımda ise bilgisayarlı tomografi cihazı modellenmiş ve radyasyon dozu hesaplamaları Monte Carlo yöntemi ile yapılmıştır. BULGULAR : Teorik hesaplamalar ve ölçümlerle elde edilen longitudinal ve lateral doz profilleri karşılaştırıldığında veriler uyumludur. Karşılaştırmalarda film dozimetrenin radyasyon duyarlılığının düşük olduğu tespit edildiği için dedektör ölçümleri temel alınmıştır. Hava kerma ölçüm sonuçları kullanılarak Monte Carlo hesaplamaları için dönüşüm katsayıları hesaplanmıştır. SONUÇLAR : Absorbe radyasyon dozu ölçüm ve hesaplama sonuçlarının kullanılan fantomun tipine, uygulanan enerjiye ve filtre yapısına bağlı olarak değiştiği görülmüştür. Kullanılan fantomların homojen malzemeden yapılması ve simetrik hacime sahip olması gerçek hasta dozunu tespit etmekte hatalar doğurabilir. Monte Carlo tekniği gerçek hasta dozunun hesaplanmasını sağlayabilir.
Özet (Çeviri)
PURPOSE : The purpose of this study is to obtain the computed tomography dose index (CTDI) values and compare it with the Monte Carlo calculation technique. MATERIAL AND METHOD : This study consists of two parts, measurement and theory. In the experiment section, the absorbed radiation dose measurements obtained with the solid state detector and film dosimeter. The measurements of CTDI were performed in the body and head phantoms. In the theory section, the machinery of computed tomography is simulated and the calculations of radiation dose are done with the Monte Carlo technique. RESULTS : When the longitudinal and lateral profiles of the theoretical calculations and measurements were compared the results found to be consistent. In the comparisons, the measurements of detector is considered more reliable since the film dosimeter system has no high radiation sensitivity than the solid state. The conversion factors obtained from the measurements of air kerma results were calculated to be used in the Monte Carlo calculations. CONCLUSIONS : It is found that the results of measurement and calculation depend on the type of phantom, the energy of the radiation and the filter type. Since the phantoms are made of homogeneous material and in symmetrical structure,it could cause the errors in the real patient dose. The Monte Carlo technique gives us the ability to calculate the real patient dose.
Benzer Tezler
- Kontrast maddenin dozimetrik etkisi
Dosimetric impact of contrast agent
YUNUS TARIK ÇETİNOĞLU
Yüksek Lisans
Türkçe
2016
Fizik ve Fizik MühendisliğiAcıbadem ÜniversitesiRadyasyon Onkolojisi Ana Bilim Dalı
PROF. DR. ENİS ÖZYAR
- Tüm vücut cilt ışınlamalarında foton kullanımının dozimetrik değerlendirilmesi
Dosimetric evaluation of photon use in whole body skin irradiation
MEHMET ALİ KAYA
Doktora
Türkçe
2023
Radyasyon OnkolojisiDicle ÜniversitesiFizik Ana Bilim Dalı
PROF. DR. MEHMET ZAFER KÖYLÜ
- Radyoterapide kullanılan genis hüzmeli görüntüleme cihazları için bir kalite kontrol fantomunun tasarlanması
The design of quality control phantom for cone beam imaging devices which used in radiotherapy
GÜLŞAH KOCA
Yüksek Lisans
Türkçe
2015
Fizik ve Fizik MühendisliğiAkdeniz ÜniversitesiFizik Ana Bilim Dalı
YRD. DOÇ. DR. NİNA TUNÇEL
- Serviks ve endometrium kanserlerinde VMAT, IMRT ve 3 boyutlu konformal planlama tekniklerinin dozimetrik olarak karşılaştırılması: Retrospektif çalışma
Dosimetric comparison of VMAT, IMRT and 3-d conformal planning techniques in cervix and endometrium cancers: Retrospective research
EBRU CANTÜRK
Yüksek Lisans
Türkçe
2017
OnkolojiUludağ ÜniversitesiRadyasyon Onkolojisi Ana Bilim Dalı
PROF. DR. ORHAN GÜRLER
- Beyin tümörlerinin stereotaktik radyocerrahisinde mikro-çokyapraklı kolimatör etkisinin dozimetrik değerlendirilmesi
Dosimetric evaluation of the micro-multileaf collimator width on SBR-applied brain tumors
KADİR TAŞPINAR
Yüksek Lisans
Türkçe
2018
OnkolojiSağlık Bilimleri ÜniversitesiRadyasyon Onkolojisi Ana Bilim Dalı
PROF. DR. BAHAR DİRİCAN