Bir sentetik kannabinoid olan XLR-11 metabolitlerinin idrarda miktar tayini ve validasyonu
Determination and validation of A synthetic cannabinoid XLR-11 metabolites in urine
- Tez No: 406670
- Danışmanlar: YRD. DOÇ. DR. AYŞEN CÜCÜ
- Tez Türü: Yüksek Lisans
- Konular: Kimya, Adli Tıp, Chemistry, Forensic Medicine
- Anahtar Kelimeler: Kanabinoidler, Kromatografi-sıvı, Kütle spektrometri, Metabolitler, İdrar, İdrar tahlili, Cannabinoids, Chromatography-liquid, Mass spectrometry, Metabolites, Urine, Urinalysis
- Yıl: 2015
- Dil: Türkçe
- Üniversite: Marmara Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Analitik Kimya Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Yapılan literatür araştırmalarında, idrarda XLR-11 maddesinin metabolitlerinin eş zamanlı tayinine ilişkin herhangi bir LC-MS/MS çalışmasına rastlanmamıştır. Bu nedenle çalışmamızda XLR-11 N-(4-hidroksipentil) ve XLR-11 N-(4-pentenil) analog metabolitlerinin eş zamanlı tayinine ilişkin basit, hızlı, kesinliği yüksek, tayin edilebilir sınırı düşük bir LC-MS/MS yöntemi geliştirilmesi amaçlanmıştır. Gereç ve Yöntem: Geliştirdiğimiz yöntemde kolon olarak ACQUITY UPLC® HSS C18 (1,8 μm, 2,1 x 150 mm), mobil faz olarak (pH= 3,00; 5,0 mM tampon çözeltisi) (% 1' lik formik asitli asetonitril) gradient pompa sistemi ile, 5,00 μL' lik enjeksiyon hacminde 0,5 mL/dk akış hızı ile çalışıldı. Kütle spektrometresi analizleri Waters TQD LC-MS/MS sistemi kullanılarak gerçekleştirildi. Bulgular: Alıkonma zamanı XLR-11 N-(4-hidroksipentil) için 2,75 dakika, XLR-11 N-(4-pentenil) analog için 3,33 dakika ve iç standart desipramin için 2,13 dakika bulunmuştur. Sonuçlar: Geliştirilen yöntemde geçerli kılma için; seçicilik, kantitatif alt sınırı, kalibrasyon eğrisi performansı, doğruluk, kesinlik, matriks etkileri ve stabilite parametrelerine bakılmıştır.Yöntem XLR-11 N-(4-hidroksipentil) için 6,00 – 60,00 ng/mL ve XLR-11 N-(4-pentenil) analog için 51,45 – 514,50 ng/mL aralıklarında doğrusal bulunmuştur.
Özet (Çeviri)
Objective: According to the literature survey, there is no report for any LC-MS/MS study relevant to the simultaneous determination of XLR-11 metabolites in urine. Therefore, we aimed to develop a simple, fast, precise and sensitive LC-MS/MS method relevant to the simultaneous determination of metabolites XLR-11 N-(4-hydroxypentyl) and XLR-11 N-(4-pentenyl) analog. Material and Methods: In our method which we developed, as a column ACQUITY UPLC® HSS C18 (1,8 μm, 2,1 x 150 mm) was used, as a mobile phase (pH: 3,00, 5,0 mM buffer solution) (acetonitrile containing 1% formic acid) was used. With a gradient pump system, injection volume was 5,00 μL and 0,5 ml/min was flow rate. The analyses of mass spectrometer were done using Waters TQD LC-MS/MS system. Results: The retention time was 2,75 minutes for XLR-11 N-(4-hydroxypentyl), 3,33 minutes for XLR-11 N-(4-pentenyl) and 2,13 minutes for internal standard desipramine. Conclusion: For the validation of the method, selectivity, lower limit of quantitation, calibration curve performance, accuracy, precision, matrix effects and stability parameters were determined. It has been found that the method was linear between 6,00 – 60,00 for XLR-11 N-(4-hydroxypentyl) and 51,45 – 514,50 ng/mL for XLR-11 N-(4-pentenyl) analog.
Benzer Tezler
- Aminoalkilindol grubu içeren sentetik uyuşturucu maddelerin tayininde spektrofotometrik ve kromatografik yöntemlerin geliştirilmesi
Development of spectrophotometric and chromatographic methods for determination of synthetic narcotic substances containing aminoalkylindole group
HASAN DURMUŞ
- Bir sentetik kannabinoid olan JWH-018'in sıçanlarda hemodinami ve davranış üzerine etkisi
Effect of a synthetic cannabinoid JWH-018 on hemodynamics and behavior in rats
GİZEM ŞEN
Yüksek Lisans
Türkçe
2018
FizyolojiCelal Bayar ÜniversitesiFizyoloji Ana Bilim Dalı
PROF. DR. NURAN EKERBİÇER
- Bir sentetik kannabinoid olan RCS-4 bileşiğinin ve metabolitinin LC-MS/MS ile serum örneğinden tayini
Determination of a synthetic cannabinoid RCS-4 with its metabolite from serum sample by LC-MS/MS
NAGEHAN ADIÖREN
Yüksek Lisans
Türkçe
2024
Kimyaİstanbul Üniversitesi-CerrahpaşaFen Bilimleri Ana Bilim Dalı
DOÇ. DR. ZEYNEP TÜRKMEN
- Sentetik kannabinoid ve opioid kullanım bozukluğu olan hastalarda frontal işlevlerin karşılaştırılması: Kontrollü bir çalışma
A controlled study: Comparison of frontal functions inpatients with cannabis use disorders and opioid usedisorders
EMİNE YAĞMUR ATAY
Tıpta Uzmanlık
Türkçe
2019
PsikiyatriSağlık Bilimleri ÜniversitesiRuh Sağlığı ve Hastalıkları Ana Bilim Dalı
DOÇ. DR. MERİH ALTINTAŞ
DOÇ. DR. YUSUF ÖZAY ÖZDEMİR
- Sentetik kannabinoid kullanım bozukluğu olan olguların diffüzyon tensör görüntüleme yöntemi ile beyaz cevher bütünlüğü açısından sağlıklı kontrollerle karşılaştırılması
Comparison the white matter integrity between synthetic cannabinoid use disorders cases and healthy controls by diffusion tensor imaging
ÇİĞDEM ÇOLAK KALAYCI
Tıpta Uzmanlık
Türkçe
2015
Psikiyatriİzmir Katip Çelebi ÜniversitesiPsikiyatri Ana Bilim Dalı
DR. NABİ ZORLU