Geri Dön

Alkil kurşun bileşiklerine maruziyetin biyolojik izlenmesi

Başlık çevirisi mevcut değil.

  1. Tez No: 40436
  2. Yazar: YALÇIN DUYDU
  3. Danışmanlar: PROF.DR. NEVİN VURAL
  4. Tez Türü: Doktora
  5. Konular: Eczacılık ve Farmakoloji, Pharmacy and Pharmacology
  6. Anahtar Kelimeler: Biyolojik izleme, Tetraetil kurşun maruziyeti, Kurşun, Tetraetil kurşun, ALA, Benzin, Levulinik asitler, Biological monitoring, Tetraethyllead exposure, Lead, Tetraethyllead, ALA, Gasoline, Levulinic acids
  7. Yıl: 1995
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Belirtilmemiş.
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

80 VI ÖZET Çalışmamızda rafineri işçileri (rr.49), benzin istasyonları çalışanları (n:42) ve ellerini benzinle yıkayan oto tamircilerinde (n:50) organik kurşun maruziyeti araştırılmıştır. Kontrol grubu olarak şehir içinde yaşayan insanlar (kontrol I, n:35) ve kırsal kesimde yaşayan insanlar (kontrol II, n:20) olmak üzere iki ayrı grup kullanılmıştır. Maruziyet ve kontrol gruplarında idrarda kurşun tayini için yöntem geliştirilmiştir. İdrarda kurşun tayin edilmesine yönelik FAAS ile bilinen pek çok yöntem olmasına rağmen bu çalışma için analiz yönteminin daha duyarlı hale getirilmesi gereği ortaya çıkmıştır. Bu nedenle FAAS-yarıklı kuars tüp (atom yakalama tekniği) ve şelasyon-ekstraksiyon yöntemleri kombine olarak kullanılmış ve hassasiyet 4.43 kez arttırılmıştır. Bu sayede çok düşük idrar kurşun konsantrasyonları ile karşılaşıldığında bile (özellikle kontrol gruplarında) güvenilir ölçümlerin yapılabilmesi mümkün olmuştur (duyarlılık: 0.030 jıg/ml). Rafineri işçilerinde ortalama idrar PbT değerleri 105.52 (27.45-239.22) \xg Pb/I ve 91.07 (42.56-209.83) ng Pb/g kreatinin, ortalama PbO/PbT oranı ise 0.28 olarak bulunmuştur. Ellerini benzinle yıkayan oto tamircilerinde yaptığımız araştırmada ortalama PbT değerleri 89.15 (34.96-241.82) ng Pb/I ve 67.25 (15.89-160.71) ^g Pb/g kreatinin, ortalama PbO/PbT oranı ise 0.31 olarak bulunmuştur. Üçüncü maruziyet grubu olan benzin istasyonları çalışanlannda ortalama idrar PbT değerleri 85.42 (18.14-238.52) ng Pb/I ve 74.24 (22.12-189.46) ng Pb/g kreatinin, ortalama PbO/PbT oranı ise 0.33 olarak bulunmuştur. Kontrol I grubunda tespit edilen ortalama PbT değerleri 51.58 (22.45-85.42) \xg Pb/I ve 50.52 (25.46-87.79) ^g Pb/g kreatinin, Kontrol II grubunda ise 7.18 (3.38-12.58) ug Pb/I ve 6.96 (3.84-16.56) ^g Pb/g kreatinin olarak81 bulunmuştur. Rafineri işçileri, oto tamircileri ve benzincilerde ölçülen ortalama kurşun konsantrasyonları her iki kontrol grubuna göre de yüksek bulunmuştur (p<0.05). Rafineri işçileri ve ellerini benzinle yıkayan oto tamircilerinde idrarla atılan ALA miktarlan da incelenmiştir. Rafineri işçilerinde ortalama 2.50 (0.95-8.21) mg/l ALA ve ellerini benzinle yıkayan oto tamircilerinde ise ortalama 2.42 (0.90-5.66) mg/l idrar ALA tespit edilmiştir. Rafineri işçileri ve oto tamircilerinde yaptığımız çalışmalarda İdrarla atılan PbT konsantrasyonu ile idrarla atılan ALA arasında anlamlı bir ilişinin olduğu gösterilmiştir.

Özet (Çeviri)

82 Vn. SUMMARY In this study we investigated organolead exposure in refinery workers, gasoline station workers and in motor mechanics who use gasoline as a cleaning agent for cleaning their hands. Control urine samples were collected from the subjects who were living in Ankara (Control I) and 30 km away from Ankara (Control II). At the begining of the study, we tried to modify the conventional urine lead determination method by FAAS to impruve its sensitivity. The best sensitivity was achieved when we used FAAS-Slotted Tube Atom Trap (STAT) in combination with organic solvent extraction procedure. The sensitivity of the assay was increased 4.43 times by this procedure. This modified method allowed us to determine the low Pb concentrations particularly in control groups. 49 urine samples were collected from the refinery workers. The mean levels of PbT in urine were found 105.52 (27.45-239.22) ng Pb/I and 91.07 (42.56-209.83) jxg Pb/g creatinine and the mean PbO/PbT ratio were calculated as 0.28. 50 urine samples were collected from the motor mechanics. The mean levels of PbT in urine were found 89.15 (34.96-241.82) u,g Pb/I and 67.25 (15.89-160.71) \xg Pb/g creatinine and the mean PbO/PbT ratio were calculated as 0.31. 42 urine samples were collected from the gasoline station workers. The mean levels of PbT in urine were found 85.42 (18.14-238.52) |ig Pb/I and 74.24 (22.12- 189.46) ng Pb/g creatinine and the mean PbO/PbT ratio were calculated as 0.33. The mean PbT levels in all exposure groups were found significantly (p<0.05) higher than control groups (control I and control II). The mean PbT levels in control I83 and control I! were found 51.58 ± 14.20 ng/l (50.52 ± 17.36 ^g/g kreatinin) and 7.18 ± 2.59 ng/l (6.96 ± 3.43 \xq/q kreatinin) respectively. In the last part of our study we determined the urine ALA levels in both refinery workers and motor mechanics. The mean urine ALA levels in both groups were found 2.50 (0.95-8.21) mg/l and 2.42 (0.90-5.66) mg/l respectively. We also observed a positive correlation between urine PbT and urine ALA excretion in refinery workers (r8= 0.6583, n= 49, p<0.001) and motor mechanics (rs= 0.4876, n= 50, p<0.001).

Benzer Tezler

  1. Sulfation charactristics of limestone in SO2-Rich atmospheres: Mechanisms and kinetics

    Kireçtaşının yüksek SO2 içeren ortamlarda sülfatlanma karakteristiği: Mekanizma ve kinetik

    ÖZGÜR BİLİNÇ YILMAZ

    Yüksek Lisans

    İngilizce

    İngilizce

    1998

    Metalurji Mühendisliğiİstanbul Teknik Üniversitesi

    Metalurji Mühendisliği Ana Bilim Dalı

    PROF. DR. OKAN ADDEMİR

  2. Taç eter substitue yeni ftalosiyaninler

    Novel phthalocyanines with crown ether substituents

    EMEL MUSLUOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    1994

    Kimyaİstanbul Teknik Üniversitesi

    PROF.DR. ÖZER BEKAROĞLU

  3. Seramik çalışanlarında nicel kurşun düzeylerinin araştırılması

    Başlık çevirisi yok

    GAMZE ÖZTÜRK

    Yüksek Lisans

    Türkçe

    Türkçe

    2000

    Eczacılık ve FarmakolojiEge Üniversitesi

    Farmasötik Toksikoloji Ana Bilim Dalı

    PROF. DR. FERZAN LERMİOĞLU

  4. Yenidoğanlarda kord kanı kurşun düzeyi

    Başlık çevirisi yok

    HÜLYA SELVA BİLGEN

  5. Anodik sıyırma voltametrisi ile böbrek taşında kurşun ve bakır tayini

    Determination of lead and copper in kidney stone by anodic stripping voltammetry

    SEVTAP EROL

    Yüksek Lisans

    Türkçe

    Türkçe

    1996

    KimyaGazi Üniversitesi

    DOÇ.DR. HASAN AYDIN