Geri Dön

Meme tümörlerinin benign-malign ayırımında mamografi, ultrasonografi ve renkli doppler görüntülemenin yeri

Başlık çevirisi mevcut değil.

  1. Tez No: 40208
  2. Yazar: METE ÖZDİKİCİ
  3. Danışmanlar: PROF. DR. ZEKİ BAKIR
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Mamografi, Meme, Meme neoplazmları, Ultrasonografi, Ultrasonografi-renkli doppler, Mammography, Breast, Breast neoplasms, Ultrasonography, Ultrasonography-color doppler
  7. Yıl: 1995
  8. Dil: Türkçe
  9. Üniversite: Atatürk Üniversitesi
  10. Enstitü: Tıp Fakültesi
  11. Ana Bilim Dalı: Belirtilmemiş.
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZET Çalışmamız, benign ve malign meme lezyonlarının ayırımında mamografi, ultrasonografi ve renkli Doppler görüntülemenin yerini belirlemek için yapıldı. Sonuçlar literatür bilgileriyle karşılaştırıldı. Meme lezyonu tespit edilen 52 kadın hasta mamografi, ultrasonografi ve renkli Doppler görüntüleme metodları kullanılarak incelendi, Kistik lezyonlar dışlanarak, solid lezyonların mamografîk, sonografik ve Doppler görünümlerine göre benign- malign ayırımı yapılmaya çalışıldı. Tümör içinde veya komşuluğundaki damar sayısı belirlendi. Her bir damarın Doppler spektrurnu karakterize edildi ve maksimum hız kayıtları yapıldı. Bütün olgular histopatolojik değerlendirmeye tabii tutuldu. İncelemeye alınan 52 hastanın mamografiyle 21'i, ultrasonografiyle 25'i ve renkli Doppler görüntüleme ile de 14'ii malignensi tanısı almaktaydı. Olgularımızın 31'i benîgn, 211 malign histopatolojik tanı aldı. Benian lezyonların % 32'sinde ve malign lezyonların % 86'sında kan akımı gösterildi. Lezyon büyüklüğü ile damar sayısı arasındaki ilişki anlamlı bulundu (r: 0.55). Malign lezyonların anlamlı olarak daha yüksek maksimum hızlara sahip oldukları saptandı (ortalama, malign; 22.6 em/sn, benign; 12.0 cm/sn; p<0.05). Meme malignitesinin tespitinde mamografinin sensitivitesi % 76, spesifisitcsi % 84, pozitif tahmin değeri % 76, negatif tahmin değeri % 84 ve doğruluk orani % 81 olarak belirlendi. Ultrasonografi % 9Ö'hk sensitivite. % 87lik spesifisite, % 76'lık pozitif tahmin değeri, % 93'lük negatif tahmin değeri ve % 85'lik doğruluk oranı göstermekteydi. Renkli Doppler görüntüleme de % 57 sensitivite, % 94 spesifisile, % 86 pozitif tahmin değeri, % 76 negatif tahmin değeri ve % 79 doğruluk oranına sahipti. Biz, bu modalitelerin meme lezyonlarının benign-malign ayırımında biribirlerinin tamamlayıcısı olacaklarını ve renkli Doppler görüntülemenin en iyi uygulama şeklinin mamografi ve ultrasonografi kombinasyonu ile olacağı kanaatine vardık.

Özet (Çeviri)

65 SUMMARY A study was performed to determine the value of mammography, ultrasonography, and color flow imaging in differentiation between benign and malignant breast lesions. The results were compared with data in the literature. We examined 52 women patients with breast disease using these modalities. The cystic lesions were excluded from analysis. The solid lesions were characterised as benign or malignant on the basis of their mammographic, sonographic, and color flow imaging appearances. The number of blood vessels detected in or round of tumour was estimated, the Doppler spectrum for each vessel was characterised, and the maximum velocity was recorded. Histology was obtained in all cases. Of 52 women patients studied with mammography, ultrasonography, and color flow imaging when appropriate, subsequently 21, 25, and 14 received a diagnosis of probably malignant lesions. The histological diagnosis was benign in 31 cases and malignant 21 cases. Blood flow was demonstrated in 32% of benign lesions and 86% of malignant lesions. There was relationship between the size of lesion and the number of blood vessels (r:0.55). Malignant lesions showed significantly higher maximum velocity (mean, 22.6 vs 12.0 cm/sec: p<0.05). Mammography gave an overall sensitivity of 76%. specificity of 84%, positive predictive value of 76%. negative predictive value of 84%, and accuracy of 81% for the diagnosis of breast malignancy. Ultrasonography gave an overall sensitivity of 90%. specificity of 87%. positive predictive value of 76%. negative predictive value of 93%, and accuracy of 85%. Color flow imaging gave an overall sensitivity of 57%, specificity of 94%, positive predictive value of 86%, negative predictive value of 76%, and accuracy of 79%. We concluded that these modalities helped to differentiate between benign and malignant breast lesions. The best use of color flow imaging is in combination with mammography and ultrasonography.

Benzer Tezler

  1. Mesane tümörlerinde östrojen reseptörleri ve prognostik önemi

    The Prognostic significance of estrogen receptors in bladder cancer

    ALPER BAŞAKÇI

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2000

    ÜrolojiDokuz Eylül Üniversitesi

    Üroloji Ana Bilim Dalı

    PROF. DR. ZİYA KIRKALİ

  2. Meme kanserleri ve selim meme hastalıklarında lökosit arilsülfataz-A aktivitesinin değerlendirilmesi

    Evaluation of leukocyte arylsulphatase-A activity in patients with breast cancer and benign breast diseases

    SEMBOL TÜRKMEN

    Doktora

    Türkçe

    Türkçe

    1997

    Onkolojiİstanbul Üniversitesi

    Temel Onkoloji Ana Bilim Dalı

    PROF. DR. PERNUR ÖNER