Geri Dön

Anomaly detection in electrical power system using phasor measurement units

Güç elektrik sistemlerinde faz ölçüm birimleri yöntemi ile anomali belirlemesi

  1. Tez No: 397906
  2. Yazar: KHURRAM SHABBIR
  3. Danışmanlar: PROF. DR. ŞAHİN SERHAT ŞEKER
  4. Tez Türü: Yüksek Lisans
  5. Konular: Elektrik ve Elektronik Mühendisliği, Electrical and Electronics Engineering
  6. Anahtar Kelimeler: Arıza arama, Dalgacık dönüşüm tekniği, Elektrik güç sistemleri, Elektrik iletimi, Enerji yönetim sistemleri, Faz açısı, Ferrorezonans, Fourier dönüşümü, Sayısal işaret işleme, İletim hattı arızaları, Fault detection, Wavelet transforms technique, Electric power systems, Electric transmission, Energy management systems, Phase angle, Ferroresonance, Fourier transformation, Digital signal processing, Transmission line faults
  7. Yıl: 2015
  8. Dil: İngilizce
  9. Üniversite: İstanbul Teknik Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Elektrik Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu tez çalışması, Matlab PMU'lar modeli ile ölçülen PMU verilerini kullanarak öncü bir yaklaşım sağlamıştır. Bu çalışmada MATLAB SIMULINK'in simülasyon ortamında, özellik çıkarımı için çeşitli sinyal işleme teknikleri kullanılarak bölgeler arası (inter-area) osilasyonlar, ferrorezonans vb gibi anormallikler tesbit edilmiştir. Çeşitli senaryoları simüle etme amacıyla bir sanal deney düzeneği (test-bed) sağlanarak, güç sistemi operasyonlarında herhangi bir istenmeyen durum tespit analizinin gerçekleştirilebilirliği amaçlanmıştır. Geniş Alan İzleme Sistemi ve kontrol gibi diğer uygulmalarla birlikte şebeke yönetimine bir bütün olarak bakıldığında, daha güvenilir bir şebeke yönetimi için umut verici bir gelecek sağlayacaktır. Elektrik kesintileri PMU'lar tarafından sağlanan durumsal farkındalık yoluyla önlenebilir. Böylece şebeke geliştirilmiş güvenirliğe sahip olarak çalıştırılacaktır. Kısacası, WAMS güç sistemi salınımlarının güvenilir olarak izlenmesi ve tesbiti gelecekteki güç şebekelerinin en kritik uygulamalarından biri olacaktır. Ayrıca, sistem operatörleri ve algılama algoritmaları için artan titreşimler ve istikrarsızlıklardan da değerli bilgiler sağlanacaktır. Bu sistem gözetimin sağladığı bir deneyim olarak, operatörler için faydalı bir bilgiye dönüştürülebilir. Böylece operatörler eşzamanlı anlar sırasında oluşan veri ve olayları karşılaştırarak istikrarsızlığın ana nedenini bulmak üzere gözlem yapmak ve senkronize fazör ölçümlerini izlemek için uyarılabilir. Ayrıca, gelecekteki istikrarsızlıklardan korunmak için düzeltici eylemler de devreye alınabilir.

Özet (Çeviri)

In this study using MATLAB SIMULINK simulation environment is used to detect anomalies like inter-area oscillations, ferroresonance etc. utilizing several signal processing techniques for feature extraction. This will provide a virtual experimental setup (test-bed) to simulate various scenarios so that analysis can be carried out to detect any undesirable situation in the power system operation. It has been shown through the simulated scenarios i.e. detection of inter-area oscillations and ferroresonance phenomenon, that PMUs measurement can successfully achieved the desired results. These applications along with other similar one in Wider Area Monitoring System provides the promising future which will ensure better monitoring, control and grid management on the whole. Blackouts can be avoided through the situational awareness provided by the PMUs. Hence, grid can be operated with enhanced reliability. In short, WAMS reliable detection and monitoring of power system oscillations will be one of the most critical applications of the future power networks. So that a valuable information of increasing oscillations and instability be provided to the system operators and detection algorithms. In addition, operator can be alerted to observe and monitor the synchronized phasor measurements to find the root cause of instability by comparing the data and events occurred during the same time instants. Also, corrective actions can be taken to safe guard the further instability

Benzer Tezler

  1. İlkokul çağı erkek çocuklarında inmemiş testis anomalisi ve insidansı

    The anomaly and incidence of cryptorchidism in primary school boys

    SERDAR SEZGİN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1986

    ÜrolojiGazi Üniversitesi

    Üroloji Ana Bilim Dalı

  2. Bouguer gravite anomalilerinin ayrımında polinomial yaklaşımın en küçük kareler yöntemiyle çözümü ve irdelenmesi

    Başlık çevirisi yok

    SİNAN DEMİREL

    Yüksek Lisans

    Türkçe

    Türkçe

    1984

    Jeofizik Mühendisliğiİstanbul Üniversitesi

    Jeofizik Mühendisliği Ana Bilim Dalı

    PROF.DR. ALİ YARAMANCI

  3. Lexikalische interferenzfehler

    Başlık çevirisi yok

    TAHİR BALCI

    Yüksek Lisans

    Almanca

    Almanca

    1987

    Eğitim ve ÖğretimAnadolu Üniversitesi

    PROF. DR. NEVİN SELEN

  4. Çubukludağ (Cumaovası-İzmir) yöresi kayaçlarının radyoaktivite açısından incelenmesi

    Başlık çevirisi yok

    SİBEL GÜNDÜZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1988

    Jeoloji MühendisliğiEge Üniversitesi

    Nükleer Bilimler Ana Bilim Dalı

    DOÇ. DR. CAHİT HELVACI