İmplantın“Pier abutment”olarak kullanıldığı doğal diş-implant bağlantılı sabit protetik restorasyonların biyomekanik analizi
Biomechanical analysis of tooth-implant supported fixed partial dentures when an implant serves as a pier abutment
- Tez No: 358941
- Danışmanlar: PROF. DR. KADRİYE FUNDA AKALTAN
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Doğal diş-implant bağlantısı, rijit olmayan konnektör, biyomekanik analiz, pier abutment, sonlu eleman analizi, Dental bonding, Dental implantasyon, Dental implantlar, Dental materyaller, Dental stres analizi, Osseointegrasyon, Sonlu elemanlar analizi, Tooth-implant connection, non-rigid connector, biomechanical analysis, pier abutment, finite element analysis, Dental bonding, Dental implantation, Dental implants, Dental materials, Dental stress analysis, Osseointegration
- Yıl: 2014
- Dil: Türkçe
- Üniversite: Ankara Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Diş Hekimliği Bölümü
- Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Osseointegrasyon sayesinde tam ve bölümlü dişsiz çenelerin sabit ve hareketli protezlerle rehabilitasyonunda dental implantlar en önemli seçenek haline gelmiştir. İmplantların tek başına veya doğal dişlerle bağlantılı şekilde kullanılması konusunda implant ve dişin farklı mobilitelere sahip olması sistemi karmaşık hale getirir. İmplantın pier destek olarak doğal dişlerle desteklendiği sabit protetik restorasyonların biyomekanik açıdan değerlendirilmesi gerekmektedir. Çalışmamızın amacı; implantın pier desteği olarak kullanıldığı implant-diş destekli sabit restorasyonlarda, hassas bağlantının farklı konumlarda kullanılmasıyla oluşturulan rijit olmayan üst yapı tasarımlarınını, rijit ve kanatlı tasarımlarla mukayeseli olarak, 3 boyutlu sonlu elemanlar stres analiziyle değerlendirmektir. Çalışmamızda; alt çene modeli kullanılmış olup, implantın pier abutment olarak kullanıldığı 8 farklı üst yapı tasarımı (6 adet rijit olmayan, 1 adet rijit ve 1 adet kanatlı) modellenmiştir. Her bir modele dik, 30º açılı, gövdelere azaltılmış dik ve gövdelere azaltılmış açılı olmak üzere dört farklı yükleme koşulu uygulanarak, toplam 32 adet çalışma grubu oluşturulmuştur. Uygulanan kuvvetler sonucunda kortikal ve spongioz kemikte oluşan maksimum ve minimum asal gerilmeler, implant ve metal altyapı materyallerinde meydana gelen von Mises gerilme değerleri ölçülmüştür. Bununla birlikte destek dişler ve/veya implanttaki intrüzyonu değerlendirmek amacıyla vertikal (z) ve toplam (m) yer değiştirme incelenmiştir. Çalışmamızın sınırları içerisinde, elde edilen sayısal veriler sonucunda, diğer tasarımlara göre kanatlı tasarımın implant çevresinde, rijit tasarımın ise periodontal desteği molar dişe göre daha zayıf olan kanin dişte daha yüksek gerilmelere ve yer değiştirmelere neden olduğu gözlenmiştir. Hassas bağlantının implantın hem mezial hem distalinde ve implantın sadece distalinde kullanıldığı tasarımlar implant etrafındaki kemikte en uygun gerilme dağılımını oluşturmuştur.
Özet (Çeviri)
The use of dental implants has expanded over the past decades to include anterior and posterior regions of both arches in edentulous and partially edentulous patients, however the choice of using self-supporting implants or implants together with natural teeth in anatomically limited areas remains controversial. While splinting the implant and tooth is a rational alternative in some clinical situations, the dissimilar mobility patterns of the osseointegrated implants and natural teeth make the biomechanical behavior of the entire system complicated. In addition, tooth-implant supported fixed partial dentures when an implant serves as a pier abutment should be evaluated biomechanically. The aim of this study is to evaluate the stress transmission characteristics of various non-rigid connection designs performed with placing the precission attachment(s) in different locations for a tooth-implant supported fixed fartial denture when an implant serves as a pier abutment compared to a rigid and a cantilever design. In this study, mandible bone models were generated to represent 8 different prosthesis design (6 non-rigid, 1 rigid and 1 cantilever). A total number of 32 groups were prepared, each design consisting of a different loading protocol, including vertical, oblique (30º), vertical reduced force on pontics and oblique reduced force on pontics. The maximum and minimum principal stresses in cortical and spongeous bone, the von Misses stresses in the implant and metal framework as a result of the applied forces were measured. In order to evaluate the intrusion of the supporting tooth and the implant, the vertical (z) and the total (m) displacement values were calculated. Within the limitations of this study, numerical data showed that the cantilever design caused more stress and displacements around the implant and the rigid design lead to more stress around the canine tooth which has the less periodontal support than a molar tooth. The designs in which the precision attachment placed in both mesial and the distal side of the implant and only distal side of the implant generated the most favorable stress distribution around the implant.
Benzer Tezler
- Implantüstü protezlerde farklı materyal ve tekniklerle hazırlanmış protez alt yapılarının pasif uyumlarının sonlu elemanlar analizi ile değerlendirilmesi
A finite element analysis: Passive fit of implant supported dentures frameworks prepared with different materials and technics
GİZEM NUR ÖZTÜRK
Doktora
Türkçe
2019
Diş Hekimliğiİstanbul ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. BELKIS GÜLSEN BAYRAKTAR
- Dental implantın cerrahisini takiben düşük enerjili laser uygulamasının osseointegrasyon üzerine etkisinin rezonans frekans analizi ile değerlendirilmesi
Evaluation of the effect of low level laser therapy on osseointegration after dental implant surgery with resonance frequency analysis
SILA ŞAHİN
Doktora
Türkçe
2012
Diş HekimliğiAnkara ÜniversitesiAğız, Diş ve Çene Cerrahisi Ana Bilim Dalı
PROF. DR. ÜMİT KIYMET AKAL AKTAŞ
- Kontraseptif yöntemlerden ciltaltı implantın etkinliği ve hasta uyumu
Başlık çevirisi yok
BEYHAN YILDIZBAŞ
Tıpta Uzmanlık
Türkçe
2005
Kadın Hastalıkları ve DoğumYüzüncü Yıl ÜniversitesiKadın Hastalıkları ve Doğum Ana Bilim Dalı
DOÇ.DR. GÜLER ŞAHİN
- Farklı makrogeometriye sahip iki implantın erken ve konvansiyonel yükleme sürelerinde klinik ve radyografik olarak incelenmesi
Clinical and radiological outcomes two types of implants with different macrogeometries in early and conventional healing times
ALPER SAĞLANMAK
Doktora
Türkçe
2015
Diş Hekimliğiİstanbul ÜniversitesiOral İmplantoloji Ana Bilim Dalı
PROF. DR. ZİHNİ CÜNEYT KARABUDA
- Alveolar distraksiyon sonrası yerleştirilen üç farklı tip implantın çevre dokulara etkisinin üç boyutlu modelleme ve sonlu elemanlar analizi ile incelenmesi
Evaluation of the effects of the three different types of implants to the surrounding tissues by using three dimensional modelling and finite element analysis
FİRDEVS VEZİROĞLU
Doktora
Türkçe
2005
Diş HekimliğiGazi ÜniversitesiAğız, Diş ve Çene Cerrahisi Ana Bilim Dalı
PROF.DR. DERVİŞ YILMAZ