Biomechanical assesment of posterior spinal instruments

Posterior omurga instrumanlarının biomekaniksel değerlendirilmesi

  1. Tez No: 35505
  2. Yazar: OYA KOYUNCUOĞLU
  3. Danışmanlar: PROF. DR. NURİ AKKAŞ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Mühendislik Bilimleri, Engineering Sciences
  6. Anahtar Kelimeler: Omurga, Biomekanik, Patlama Tarzı Kırık, Transpediküler Spinal Implant, Protezler ve implantlar, Spinal kırıklar, Spine, Biomechanics, Burst Fracture, Transpedicular Spinal Implant, Prostheses and implants, Spinal fractures
  7. Yıl: 1994
  8. Dil: İngilizce
  9. Üniversite: Orta Doğu Teknik Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Mühendislik Bilimleri Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZ POSTERİOR OMURGA İNSTRUMANLARININ BİOMEKANİKSEL DE?ERLENDİRİLMESİ KOYUNCUO?LU, Oya Yüksek Lisans Tezi, Mühendislik Bilimleri Ana Bilim Dalı Tez Yöneticisi: Prof. Dr. Nuri AKKAŞ Yardımcı Tez Yöneticisi: Doç.Dr. Gülin BİRLİK Eylül, 1994, 96 sayfa. Patlama tarzı omurga kırıklarının tedavisinde transpediküler implantlar yaygın olarak kullanılmaktadır. Bu çalışmada Alıcı spinal instruman ve TSRH spinal instrumanın aksiyel kompresyon yükü altındaki davranışları bio- mekanik olarak incelenmiştir. Deneylerde birbirini takip eden üç torakolumbar dana omurgası kullanılmıştır. Kırığı simüle edebilmek amacıyla ortada olan omurun gövdesi çıkarılmış ve yoğunluğu bilinen lastikten silindir yapı yerleştirilmiştir. Alıcı spinal instrumanın TSRH spinal instrumandan daha etkili bir stabilizasyon sağladığı, TSRH spinal instrumanın kontrol deneyine yakın so nuç verdiği saptanmıştır. Aynı implantların torsiyon ve fleksiyon-kompresyon yükleri altındaki etkilenmelerinin incelenmesi gereklidir. Lastikle kırık simulas- yonu umut verici bulunmuştur.

Özet (Çeviri)

ABSTRACT BIOMECHANICAL ASSESSMENT OF POSTERIOR SPINAL INSTRUMENTS KOYUNCUO?LU, Oya M.S. in Engineering Sciences Supervisor: Prof. Dr. Nuri AKKAŞ Co - Supervisor: Assoc. Prof.Dr. Gülin BİRLİK September, 1994, 96 pages Transpedicular implants are effectively used in the treatment of burst fractures. The biomechanical proficiency of the Alıcı spinal instrument and the TSRH spinal instrument under axial loads were assessed in a comparative study. In vitro calf spines were used in these experiments. The burst fracture was simulated by a rubber spacer with a known density. The Alıcı spinal instrument is significantly stiffer than the TSRH instrument. On the other hand, the TSRH system has almost no effect in stabilizing the fractured vertebral level when compared to the control group. These measures are true for the possible average axial load (450 N) that is suspected to affect a fractured spine of a sitting human. Further studies are essential to evaluate the optimum strength of the above mentioned spinal implants under torsion and flexion-compression loads. To use rubber spacers to simulate burst fractures seems promising.

Benzer Tezler

  1. Pelvis kırıklarında gazi tipi eksternal fiksatörlerin biyomekaniği

    Başlık çevirisi yok

    FEZA KORKUSUZ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1992

    Ortopedi ve TravmatolojiGazi Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

  2. Pes planuslu kişilerde fiziksel uygunluğun değerlendirilmesi

    Assessment of physical fitness parameters in pes planus with adults

    SENEM SAĞMANLI

    Yüksek Lisans

    Türkçe

    Türkçe

    2001

    Fiziksel Tıp ve RehabilitasyonHacettepe Üniversitesi

    Fizik Tedavi ve Rehabilitasyon Ana Bilim Dalı

    PROF.DR. FATİH ERBAHÇECİ

  3. Farklı yüklenmeler altında antropometrik verilere bağlı olarak fizyolojik parametrelerdeki değişimlerin incelenmesi

    Analysis of variations in physiological parameters under different loadings with respect to anthropometrical data

    BERMAN KAYIŞ(ÇİLİNGİR)

    Doktora

    Türkçe

    Türkçe

    1989

    Fizyolojiİstanbul Teknik Üniversitesi

    PROF.DR. AHMET FAHRİ ÖZOK

  4. Diz altı protezlerinde farklı statik ayarların ambulasyon ve yürüyüş üzerine etkisi

    The Effect of different static alignment procedures on the ambulation and gait of below-knee amputees

    KILIÇHAN BAYAR

    Doktora

    Türkçe

    Türkçe

    2001

    Fiziksel Tıp ve RehabilitasyonHacettepe Üniversitesi

    Fizik Tedavi ve Rehabilitasyon Ana Bilim Dalı

    PROF.DR. GÜL ŞENER