Geri Dön

Estetik bölge tek diş eksikliklerinde hemen yüklenen“platform SWITCH”implantların değerlendirilmesi

Evaluation of immediate loaded platform SWİTCH implants in the single tooth missing of esthetic zone

  1. Tez No: 353001
  2. Yazar: PINAR YILDIZ
  3. Danışmanlar: DOÇ. DR. MUSTAFA ZORTUK
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: platform switch, pembe estetik skorlama, hemen yükleme, Dental implantasyon, Dental implantlar, Dişler, Fotogrametri, Radyografi-dental, platform switch, pink esthetic score, immediate loading, Dental implantation, Dental implants, Teeth, Photogrammetry, Radiography-dental
  7. Yıl: 2014
  8. Dil: Türkçe
  9. Üniversite: Erciyes Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı üst çene estetik bölgede tek diş eksikliklerinde platform switch implantların hemen yüklenmesinin radyolojik klinik ve fotografik olarak değerlendirilmesidir. Çalışmaya üst anterior bölgede tek diş eksikliği olan 33 (23 bayan, 10 erkek) hasta katılmıştır. Bu hastaların uygun primer stabiliteye sahip 18 tanesine geçici dayanaklarla fonksiyonsuz hemen yükleme protokolü uygulanmıştır. Bu implantlardan 2 tanesi erken başarısızlık sonucu kaybedilmiştir. 15 hastaya geç yükleme protokolü uygulanmıştır. Her iki hasta grubu da daimi yükleme seansında, 1. Ay 3. Ay 6. Ay ve 12. Aylık kontrollerinde klinik olarak sondlama derinliği, kanama indexi, gingival index, plak indexi ve keratinize dişeti genişliği bakımından değerlendirilmiş, Periapikal radyografileri ve fotografları başlangıçta, 1,3,6, ve 12. Aylarda alınmıştır. Elde edilen radyograflardan marjinal kemik kaybı hesaplanmıştır. Alınan fotoğraflar pembe estetik skorlama ile 2 ayrı araştırmacı tarafından değerlendirilmiştir. Hemen yükleme grubunda 1 yıllık takibin sonucunda %88,88 başarı görülürken, geç yükleme grubunda %100 başarı görülmüştür. Hemen yükleme ve geç yükleme grubunda marjinal kemik kaybı ve pembe estetik skor değerleri arasında anlamlı bir farklılık bulunamamıştır. Pembe estetik skor değeri her iki gruptada zaman göre anlamlı derecede artış görülmüştür. Cep derinliği başlangıç ve 1. Aylarda her iki grup arasında farklı iken, kanam indexi 3 ve 6. Aylarda anlamlı derecede farklı bulunmuştur. Diğer klinik parametreler karşılaştırıldığında her iki grup arasında anlamlı bir farklılık görülmemiştir. Bu çalışmanın sonucunda doğru hasta seçimi ve iyi bir uygulama ile platform switch implantların hemen yüklemesi ile geç yüklemesi arasında klinik, radyografik ve estetik olarak anlamlı bir farklılık olmadığı ve estetik skorun zaman göre anlamlı derecede arttığı bulunmuştur.

Özet (Çeviri)

The aim of this study is evaluation of the immediate loading of platform switching implants at single tooth missings in the esthetic zone of maksilla clinically, radiographically and photographically. Thirty three (23 female, 10 male) patients who had a single missing tooth on the maksillary anterior region were participated in this study. Immediate loading protocol with temporary abutments was applied to 18 of these patients without function. Two of these implants were lost because of early dental implant failure. Delayed loading protocol was applied to the entire 15 patients. Pocket depth, bleeding index, gingival index, plaque index and keratinezed gingival width were measured during the final loading session and after 1 month, 3 months, 6 months and 12 months of loading. The periapical radiographes and photos of the patients were taken in the session of loading, after 1 month, 3 months, 6 months and 12 months of loading. Marginal bone losses were measured on the radiographes. The photos were scored and evaluated with pink esthetic score by 2 different observers. As a result of one-year follow-up, succes rate is, %88,88 for immediate loading group and %100 for delayed loading group. There was not any statistically significant difference of marjinal bone resorption and pink aesthetic score values between both groups. It was seen that the pink aesthetic score values increased by the time for both of the groups. The probing depth shows statistical difference between the groups at first month and bleeding index has significant difference between the groups at third and sixth months. There was not any significant difference between the groups for other clinical parameters. According to the results of this study with the help of proper patient selection and good practices, there would be no significant clinical, radiographic and aesthetic difference between immediate loading and delayed loading protocols. Addition to these results it was shown that aesthetic score increased significantly by the time.

Benzer Tezler

  1. Tek diş implantların klinik, radyografik, estetik ve hasta memnuniyeti açısından kontralateral dişler ile karşılaştırılması

    Comparison of single-tooth dental implants with contralateral teeth i̇n terms of clinical, radiographic, aesthetic and patient satisfaction

    MERVE KÜÇÜKOĞLU

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2021

    Diş HekimliğiZonguldak Bülent Ecevit Üniversitesi

    Periodontoloji Ana Bilim Dalı

    PROF. DR. MURAT İNANÇ CENGİZ

  2. Ön bölge tek diş implantlarında farklı abutmant materyallerinin estetiğe etkisinin karşılaştırılması

    An esthetic comparison of different abutment materials in anterior single-tooth areas

    ARZU ARZUMAN

    Doktora

    Türkçe

    Türkçe

    2009

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    YRD. DOÇ. DR. BİLGE GÖKÇEN RÖHLİG

  3. Ön bölge estetik restorasyonlarda farklı restoratif materyallerin klinik performanslarının değerlendirilmesi

    Evaluation of the clinical performance of different restorative materials in anterior aesthetic restorations

    İREM AYHAN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2024

    Diş HekimliğiKocaeli Üniversitesi

    Pedodonti Ana Bilim Dalı

    DOÇ. DR. MESUT ELBAY

  4. Estetik zirkonyum, polietereterketon ve polieterketonketon implant dayanakları üzerine yapılan lityum disilikatla güçlendirilmiş CAD/CAM monolitik cam seramik kronların yaşlandırma işlemi sonrası kırılma dayanımlarının ve kırılma tiplerinin in vitro değerlendirilmesi

    Evaluation of fracture resistance and fracture types of titanium sub-structured zirconium, polyetheretherketone, polyetherketoneketone implant abutments restored with lithium disilicate reinforced monolithic CAD/CAM glass ceramic crowns after cyclic fatique loading

    ALMİRA ADA DİKEN TÜRKSAYAR

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2019

    Diş HekimliğiKırıkkale Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. SAADET SAĞLAM ATSÜ

  5. Tek seanslı kopmlet yarık dudak damak operasyonları

    Başlık çevirisi yok

    MÜBİN HOŞNUTER

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2000

    Plastik ve Rekonstrüktif CerrahiSelçuk Üniversitesi

    Plastik Rekonstrüktif ve Estetik Cerrahi Ana Bilim Dalı

    DOÇ. DR. NEDİM SIVACI