Farklı açılarla uygulanmış konik tek tip yivli ve çift tip yivli ortodontik mini implantların primer stabilitelerinin değerlendirilmesi
Primary stability evaluation of mono and dual-thread miniscrews in different insertion angles
- Tez No: 342035
- Danışmanlar: DOÇ. DR. DERYA ÇAKAN
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Dental implantasyon, Dental implantlar, Kemik vidaları, Ortodonti, Ortodontik aygıtlar, Radyofrekans, Dental implantation, Dental implants, Bone screws, Orthodontics, Orthodontic appliances, Radiofrequency
- Yıl: 2013
- Dil: Türkçe
- Üniversite: Yeditepe Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Bu çalışmanın amacı, in vitro ortamda, farklı açılar ile yerleştirilmiş konik çift tip yivli minividalar ile tek tip yivli minividaların primer stabilitelerini, değerlendirmektir.Çalışmamızda 30 adet, 1,6 mm çapında, 8,0 mm uzunluğunda tek tip yivli, yine aynı boyutlarda 30 adet çift tip yivli olmak üzere toplam 60 adet `'Self-drilling'' özelliğine sahip minivida kullanılmıştır. Uygulama, sığır kalça kemiğinden elde edilen kemik bloklar üzerinde yapılmıştır. Yiv tasarımı ve uygulama açısına göre minividalar 4 farklı grupa dağıtılmıştır. Birinci grupta 15 adet tek tip yivli minivida kemik yüzeyine 90° açıyla, ikinci grupta 15 adet tek tip yivli minivida kemik yüzeyine 60° açıyla, üçüncü grupta 15 adet çift tip yivli minivida kemik yüzeyine 90° açıyla, dördüncü grupta 15 adet çift tip yivli minivida kemik yüzeyine 60° açıyla uygulanmıştır. Tüm minividaların implant stabilite katsayı (ISK) değerleri rezonans frekans analizi (RFA) kullanılarak ölçülmüş ve istatistiksel olarak değerlendirilmiştir.Gruplar karşılaştırıldığında, tek tip yivli minividaların 90° ve 60° açıyla uygulanmaları arasında istatistiksel olarak anlamlı bir fark görülmemiştir (p>0,05). 90°açıyla uygulandığında çift tip yivli minividaların ISK ölçümlerinin yine açıyla uygulanan tek tip yivli minividalara ve 60° açıyla uygulanan tek ve çift yivli minividalara oranla istatistiksel olarak anlamlı derecede yüksek olduğu bulunmuştur (p<0,01). 60°'lik uygulamada ise çift tip yivli minividaların, farklı açılarda uygulanan tek tip yivli minivida grupları ile aynı stabilite değerlerini gösterdiği saptanmıştır.Sonuç olarak, kortikal kemik içerisinde bağlanmaya katılan yiv sayısının artmasıyla, çift tip yivli minividalar dik açıyla uygulandıklarında tek tip yivli minividalara göre daha yüksek stabilite göstermektedir. Bununla birlikte uygulama açısının 90°'den 60°'ye değişmesi çift yivli minividaların primer stabilitelerinde azalmaya neden olmaktadır.
Özet (Çeviri)
The aim of this in-vitro study is, to evaluate the primary stability of tapered mono and dual-thread miniscrews inserted with different angles.In this study 60 self-drilling miniscrews with a diameter of 1,6 mm and a length of 8,0 mm were used. Of these 60 miniscrews, 30 were mono-thread and the remaining 30 were dual-thread miniscrews. These miniscrews were applied to bone blocks prepared from ilium of bovine. There are four groups of miniscrews according to thread designs and insertion angles. The first group consists of 15 mono-thread miniscrews which were inserted with an angle of 90° to the bone surface, the second group consists of 15 mono-thread miniscrews which were inserted with an angle of 60° to the bone surface, the third group consists of 15 dual-thread miniscrews which were inserted with an angle of 90° to the bone surface and finally the fourth group consists of 15 dual-thread miniscrews were inserted with an angle of 60° to the bone surface. All implant stability quotient (ISQ) values of miniscrews were measured with resonance frequency analysis (RFA) and statistically evaluated.When groups were compared, it has been revealed that there is no statistically significant difference between 90° and 60° insertion angles of mono-thread miniscrews (p<0.01). Furthermore, it was also revealed that the ISQ values of dual-thread miniscrews inserted with an angle of 90° were statistically significantly higher when compared to those of mono-thread miniscrews inserted with an angle of 90° and mono and dual-thread miniscrews inserted with an angle of 60° (p<0.01). Finally, results also indicated that dual-thread miniscrews inserted with an angle of 60° has the same stability values with those of mono-thread miniscrews inserted with different angles.In conclusion, as the number of threads of perpendicularly inserted dual-thread miniscrews attached to the cortical bone increases, the stability also increases compared to perpendicularly inserted mono-thread miniscrews. Besides, the change in insertion angle of dual-thread miniscrews from 90° to 60° causes a reduction in primary stability values.
Benzer Tezler
- Ortodontik mini vidaların angulasyonunun ve gövde yapısının primer stabiliteye olan etkisi: İn vitro çalışma
Effects of insertion angle and body shape on the stability of orthodontic mini screws: iİn vitro study
CANSU DÜZGÜN
Diş Hekimliği Uzmanlık
Türkçe
2018
Diş HekimliğiÇukurova ÜniversitesiOrtodonti Ana Bilim Dalı
PROF. DR. MUSTAFA SERDAR TOROĞLU
- Ortodontik minivida kullanımında güvenli bölgelerin KIBT (Konik ışınlı bilgisayarlı tomografi) ile değerlendirilmesi
Evaluation with cbct (cone-beam computerized tomography) of safe zones for orthodontic miniscrew use
ALİ KARACA
Diş Hekimliği Uzmanlık
Türkçe
2018
Diş HekimliğiSağlık Bilimleri ÜniversitesiOrtodonti Ana Bilim Dalı
DOÇ. DR. FİDAN ALAKUŞ SABUNCUOĞLU
- 3 boyutlu dijital tasarım programları ile tasarlanan farklı fiziksel parametrelere sahip sabit bant-loop yer tutucuların sonlu elemanlar analizi metoduyla kıyaslanması
Comparison of fixed band-loop space-maintainers with varying physical parameters designed using 3d digital software via finite element analysis
BERNA GÜR
Doktora
Türkçe
2025
Diş Hekimliğiİstanbul Sağlık ve Teknoloji ÜniversitesiPedodonti Ana Bilim Dalı
PROF. DR. CEYHAN ALTUN
- Evre I larinks kanseri tedavisinde konformal radyoterapi, yoğunluk ayarlı radyoterapi (yart), volümetrik ark terapi (VMAT) planlarının dozimetrik karşılaştırılması
A comparison of conformal radiotherapy, intensity modulated radiotherapy and volumetric arc therapy techniques for early stage larynx cancers
GÖZDE TOPGÜL
Yüksek Lisans
Türkçe
2017
Fizik ve Fizik MühendisliğiUludağ ÜniversitesiRadyasyon Onkolojisi Ana Bilim Dalı
PROF. DR. ORHAN GÜRLER
- Ultimate limit state design assessment and recommendation comments for offshore crane foundation
Açık deniz kreyn fandeyşını için nihai limit durum tasarımı değerlendirmesi ve tavsiye açıklamaları
MUHAMMET CÜNEYT SAKÖNDER
Yüksek Lisans
İngilizce
2019
Gemi Mühendisliğiİstanbul Teknik ÜniversitesiGemi ve Deniz Teknolojisi Mühendisliği Ana Bilim Dalı
DOÇ. DR. ÖZGÜR ÖZGÜÇ