Geri Dön

Akciğer kanserli hastalarda set-up kaymalarının çıkış dozlarıyla ilişkisinin rando fantom üzerinde termolüminesans dozimetri ile araştırılması

Research of the relation between patient set-up differences with exit doses to lung cancer patients on rando phantom with thermoluminescence dosimetry

  1. Tez No: 341909
  2. Yazar: ÖZGÜR KARA
  3. Danışmanlar: PROF. DR. LÜTFİ ÖZKAN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Onkoloji, Fizik ve Fizik Mühendisliği, Oncology, Physics and Physics Engineering
  6. Anahtar Kelimeler: Akciğer neoplazmları, Neoplazmlar, Radyometri, Radyoterapi, Termolüminesans, Lung neoplasms, Neoplasms, Radiometry, Radiotherapy, Thermoluminescence
  7. Yıl: 2013
  8. Dil: Türkçe
  9. Üniversite: Uludağ Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Radyasyon Onkolojisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı, akciğer kanserli hastaların radyoterapi tedavisi sırasındaki set-up hatalarının, çıkış dozlarına dozimetrik etkisinin rando fantom üzerinde termolimünesans dozimetri ile araştırılmasıdır. Çalışmada Uludağ Üniversitesi Tıp Fakültesi Radyoterapi Merkezi? nde bulunan rando fantom, dozimetrik ekipman ve tedavi cihazları kullanıldı. Öncelikle, her bir termolimünesans dozimetrenin (TLD) ayrı ayrı kalibrasyonu yapıldı. Kalibrasyonu yapılan TLD? ler ile çıkış dozlarının ölçümünü yapmak için rando fantom içerisinde doz çıkış bölgesinin 1,5 cm içerisindeki beş noktaya yerleştirildi. Çıkış dozlarının ölçümünün yapılması için hasta kalınlığı rando fantomun kalınlığıyla aynı olan akciğer kanserli bir hastanın yoğunluk ayarlı radyoterapi (YART) planı seçildi. Referans ölçümü alındıktan sonra alan merkezi sırasıyla her düzlemde (lateral, longitidunal ve vertikal) 1 mm, 3 mm ve 5 mm kaydırılarak ayrı ayrı ölçümler alındı. Toplamda 13 farklı set-up durumuna göre 65 adet TLD kullanılarak ölçümler yapıldı. Verilerin istatistiksel analizi yapıldı. Anlamlılık düzeyi olarak, p<0,05 kabul edilen çalışmada, elde edilen istatistik analizi sonuçlarına göre lateral, vertikal ve her düzlemde alınan çıkış dozu ölçümleri arasında anlamlı fark bulunurken, longitudinal eksendeki set-up kaymaları sonucundaki çıkış dozları arasında anlamlı bir fark bulunamamıştır. Ayrıca 1 mm kaydırma yapıldığında hiçbir düzlemde anlamlı fark bulunmazken, 3 mm ve 5 mm alan kaydırmalarında, kaydırmanın vektörel büyüklüğü arttıkça, çıkış dozu değişimi artacak şekilde anlamlı farklar bulunmuştur. Sonuç olarak, teknolojik gelişimle birlikte, tedavide yüksek dozlara çıkmamızı sağlayan üç boyutlu konformal radyoterapi ve YART gibi yöntemlerde set-up marjları düşürüldüğü ve doz dağılımları normal doku ve hedef hacim arasındaki yüksek doz gradyentleri ile geliştirildiği için hassas set-up doğrulamasının önemi dozimetrik olarak da doğrulanmıştır.

Özet (Çeviri)

The purpose of this study is to research the dosimetric effect of set-up inaccuracies to lung cancer patients on rando phantom with thermoluminescence dosimetry. In this study we use dosimetric equipment, treatment devices and rando phantom of Uludağ University Medical Faculty Radiotherapy department. At first, all thermoluminescence dosimeters (TLD) calibrated one by one. After calibration, 5 dosimeters placed to the 5 points at 1.5 cm depth from the region of exit surface of rando phantom. A patient with intensity modulated radiation therapy planned which has the same thickness with rando phantom was selected for the measurement of exit dose. After the measurement of the reference, the isocenter was changed 1 mm, 3 mm and 5 mm at all directions (lateral, longitudinal, vertical), respectively. Totally, 13 measurements made with 65 TLDs. The p<0,05 significance level was accepted and according to statistical analyses results, lateral, vertical and all directions exit doses measurements found significantly differences, barely at longitudinal direction is not significantly different. Addition to that, at any directions changes of 1 mm not found significantly difference, but at 3 mm and 5 mm differences, according to the increases of vector quantity, the exit doses are increasing significantly, too. Consequently, with the conjuction of technological development, three dimensioned conformal radiotherapy and intensity modulated radiation therapy provides high dose prescriptions at treatments, decreasing set-up margins and improve dose distributions by sharpening dose gradients between target volume and surrounding tissue is required to sensitive set-up verification and its importance verified by dosimetry also with this study.

Benzer Tezler

  1. Radyoterapi gören meme kanserli hastalarda oluşabilecek set-up farklılıklarının, simülatör ve port filmlerden faydalanılarak değerlendirilmesi

    The evalation of the set-up deviation using simulation and port films in breast cancer patients treated with radiotherapy

    SİBEL TUZLACI

    Yüksek Lisans

    Türkçe

    Türkçe

    2006

    OnkolojiAtatürk Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    Y.DOÇ.DR. MEHMET KOÇ

  2. Torasik radyoterapi uygulanan akciğer kanseri tanılı hastalarda farklı set-up pozisyonlarındaki tedavi alan deviasyonlarının incelenmesi

    Evaluatıon of the treatment fıeld devıatıons ın dıfferent set-up posıtıons durıng thoracıc radıotherapy ın lung cancer patıents

    ZELİHA GÜZELÖZ ÇAPAR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2011

    OnkolojiDokuz Eylül Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF. DR. RIZA ÇETİNGÖZ

  3. Erken evre küçük hücreli-dışı akciğer kanserinin stereotaktik ablatif tedavisinde tek ve çoklu ark tedavi planlarının dozimetrik olarak karşılaştırılması

    Dosimetric comparison of single and multiple arc treatment plans in stereotactic ablative treatment of early stage non-small cell lung cancer

    SEDA CEYLAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2021

    Sağlık EğitimiTrakya Üniversitesi

    Sağlık Fiziği Ana Bilim Dalı

    PROF. DR. MERT SAYNAK

  4. Meme kanserinde göğüs duvarı ve lenfatik ışınlamada farklı tedavi tekniklerinin tedavi planlama sistemi ve dozimetrik yöntemlerle incelenmesi

    Examination of various treatment techniques for breast cancer on the chest wall and lymphatic radiation through treatment planning system and dosimetric methods.

    MEHMET KARABUĞA

    Yüksek Lisans

    Türkçe

    Türkçe

    2010

    OnkolojiHacettepe Üniversitesi

    Klinik Onkoloji Ana Bilim Dalı

    PROF. DR. FERAH YILDIZ

  5. Akciğer kanseri nedeniyle torasik radyoterapi alan hastalarda radyasyona bağlı hasar gelişiminin akciğer ultrasonografisi bulguları ve KL-6, TGF-Beta, IFN-Gama ile ilişkisi

    The relationship of radiation-induced damage development with lung ultrasonography findings and KL-6, TGF-Beta, IFN-Gamma in patients receiving thoracic radiotherapy for lung cancer

    BAŞAK GÖNEN ATAÇER

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2025

    Radyasyon OnkolojisiTrakya Üniversitesi

    Göğüs Hastalıkları Ana Bilim Dalı

    PROF. DR. OSMAN NURİ HATİPOĞLU