Tomoterapi ile nazofarenk kanseri tedavisinin dozimetrik değerlendirilmesi

Dosimetric evaluation of the nasopharyngeal cancer with tomotherapy

  1. Tez No: 337002
  2. Yazar: HASAN UYSAL
  3. Danışmanlar: DOÇ. DR. BAHAR DİRİCAN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Radyoloji ve Nükleer Tıp, Physics and Physics Engineering, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2013
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Nükleer Bilimler Enstitüsü
  11. Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
  12. Bilim Dalı: Sağlık Fiziği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmada Nazofarenks kanseri tanılı 7 hastanın, tedavi öncesi çekilen bilgisayarlı tomografi (BT) kesit görüntüleri kullanılarak Tomoterapi cihazında tedavi için 2 ve 2,5 modülasyon faktörlerine sahip iki ayrı tedavi planlaması Tomoterapi cihazında yapılmıştır. Planlamaya ait veriler TPS?de octavius fantoma aktarılarak doz doğrulaması yapılmıştır. Planlanan hedef hacimlere (PTV 54, PTV 60 ve PTV 70) simultane integre boost (SIB) tekniği ile aynı fraksiyonda; 1,64 Gy, 1,81 Gy ve 2,12 Gy?den dozlar verilmiştir. Yapılan tedavi planlarında 2 ve 3 numaralı hastaların lenf nodları PTV 60?a dahil edilerek elektif amaçlı ışınlama yapılmış, diğer hastaların tutulu lenf nodları PTV 70?e dahil edilerek 70 Gy doz verilmiştir. Modülasyon faktörü 2,5 kullanılarak yapılan tedavi planlarında faktörün 2 kullanıldığı planlara göre; PTV 70?in maksimum dozunda % 1,44, PTV 60?ın maksimum dozunda % 0,99 ve PTV 54?ün maksimum dozunda % 0,85 oranında artış olmuştur. PTV 70?in minimum dozunda % 15,92, PTV 60?ın minimum dozunda % 1,91 oranında azalma olmuştur. PTV 54?de ise % 10,84 oranında artış olmuştur. PTV 60 ve PTV 70 kritik organlara komşu, PTV 54 ise kritik organlara daha uzaktır. Modülasyon faktörü 2,5 kullanıldığında maksimum ışın yoğunluğunu arttırarak daha iyi doz modülasyonu yapılabildiği için PTV 60 ve PTV 70?de minimum dozlar düşerken, PTV 54?de artmıştır. Hacimsel olarak bulduğumuz değerler ve homojenite indeksinin 1?e yakın olması (modülasyon faktörü 2 iken 1,05, modülasyon faktörü 2,5 iken 1,06 ) PTV 70 içerisinde soğuk bölgelerin olmadığını göstermektedir. Modülasyon faktörü 2,5 kullanılarak yapılan tedavi planlarında kritik organların maksimum dozlarında; beyin sapında % 6 ,51, spinal kordda % 5,10, sağ optik sinirde % 1,70, sol optik sinirde % 1,85, kiazmada % 0,22, mandibulada % 1,58, sağ temporomandibular eklemde % 0,87, sol temporomandibular eklemde % 1,42, sağ gözde % 67,36, sol gözde % 34,26, sağ lenste % 3.78 ve sol lenste % 2,12 ve ortalama dozlarında; oral kavitede % 4,90, larenkste % 14,40, özefagusta % 7,58, sağ parotiste % 15,03 ve sol parotiste % 5,62 düşüş görülmüştür. Kohleanın % 5?lik hacminde; sağ kohleada % 1,04?lük bir azalma ve sol kohlea?da % 12,93?lük bir artış olmuştur. Sol kohlea PTV 70?e yakınlığından dolayı doz modülasyonu işleminde kullanılmamıştır.Nazofarenks kanseri tedavisinde 2.5 modülasyon faktörünün kritik organların korunmasında daha iyi olduğu gözlemlenmiştir. ?

Özet (Çeviri)

In the present study, two individual treatment planning with 2 and 2.5 modulation factors for the treatment of 7 patients diagnosed with nasopharynx cancer in Tomotherapy device was performed by using computed tomography (CT) section images taken before the treatment. Data for planning was transferred into octavius phantom on TPS and dose confirmation was performed. Target volumes (PTV 54, PTV 60 ve PTV 70) planned were given from 1.64 Gy, 1.81 Gy and 2.12 Gy on the same fraction with simultaneous integrated boost (SIB). In the treatment planning, elective irradiation was done by including lymph nodes of patients 2 and 3 into PTV 60; invaded lymph nodes of other patients were included in PTV 70 and 70 Gy dose was given. According to the plans where factor 2 was used in treatment plans performed by running modulation factor 2.5, an increase by 1.44%, 0.99% and 0.85% on maximum dose of PTV 70, PTV 60 and PTV 54, respectively. Furthermore, a decrease by 15.92%, 1.91% occurred on minimum dose of PTV 70, PTV 60, respectively. An increase by 10.84 occurred on PTV 54. PTV 60 and PTV 70 are adjacent to critical organs and PTV 54 is far from critical organs. Since better dose modulation may be performed by increasing maximum beam density when modulation factor 2.5 is used, minimum doses decreased on PTV 60 and PTV 70 whereas increased on PTV 54. Since values that we obtained volumetrically and homogenicity index are close to 1 (1.05 with modulation factor of 2; 1.06 with modulation factor of 2.5), this shows that no cold areas exist in PTV 70. In maximum doses of critical organs in treatment plans by running modulation factor of 2.5; a decrease by 6.51% in the brain stem, 5.10% in the spinal cord, 1.70% in right optic nerve, 1.85% in left optic nerve, 0.22% in chiasm, 1.58% in the mandible, 0.87% in right temporomandibular joint, 1.42% in left temporomandibular joint, 67.36% on right eye, 34.26% on left eye, 3.78% on right lens, 2.12% on left lens were observed whereas a decrease by 4.90%, 14.40%, 7.58%, 15.03%, 5.62% were observed in oral cavity, larynx, esophagus, right parotid gland and left parotid gland, respectively. At 5 % cochlea volume; the decrease in the right cochlea was 1.04% and the increase in the left cochlea was 12.93 %.Left cochlea was not used for dose modulation operation due to it?s adjacency to PTV 70. It was observed that modulation factor of 2.5 is better for preserving critical organs in treatment of nasopharynx cancer.

Benzer Tezler

  1. Tomoterapi ile glioblastoma (GB) radyoterapisinin dozimetrik değerlendirilmesi

    Dosimetric evaluation of glioblastoma (GB) radiotherapy with tomotherapy

    ÖNDER GÜL

    Yüksek Lisans

    Türkçe

    Türkçe

    2013

    Fizik ve Fizik MühendisliğiAnkara Üniversitesi

    Sağlık Fiziği Ana Bilim Dalı

    DOÇ. DR. BAHAR DİRİCAN

  2. Tomoterapi ile tedavilerde hedef dozun farklı dozimetrik sistemler ile incelenmesi

    Investigation of the target dose with different dosimetric systems in treatments with tomotheraphy

    TAHA ERDOĞAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2014

    OnkolojiAnkara Üniversitesi

    Medikal Fizik Ana Bilim Dalı

    PROF. DR. AYŞE GÜNEŞ TANIR

    DOÇ. DR. NİYAZİ MERİÇ

  3. Prostat kanserinde tomoterapi IMRT ile 3-D konformal radyoterapinin dozimetrik karşılaştırması

    Comparison of dosimetric evaluation of 3-D conformal radiotherapy with tomotherapy IMRT in prostate cancer

    ADEM PEHLİVANLI

    Yüksek Lisans

    Türkçe

    Türkçe

    2012

    Fizik ve Fizik MühendisliğiGazi Üniversitesi

    Fizik Ana Bilim Dalı

    DOÇ. DR. YILDIZ GÜNEY

    PROF. DR. A.GÜNEŞ TANIR

  4. Tüm meme radyoterapisinde 3BKRT, for-IMRT, inv-IMRT,volümetrik ark terapi ve helikal tomoterapi ile oluşan doz dağılımları ve riskli organ dozlarının karşılaştırılması

    Comparison of dose distributions and organs at risk doses in whole breast irradiation with 3DCRT, for-İMRT, inv-İMRT, volumetric arc therapy and helical tomotherapy

    EMEL HACIİSLAMOĞLU

    Doktora

    Türkçe

    Türkçe

    2013

    OnkolojiKaradeniz Teknik Üniversitesi

    Fizik Ana Bilim Dalı

    PROF. DR. AHMET HAKAN YILMAZ

  5. Calculation of volume contraction accuracy based on CT plan using tomo therapy for head and neck cancer patients

    Tomoterapi ile tedavi edilen bas boyun kanseri hastalari icin CT planina gore hacim kuculmesinin dogrulugunun hesaplanmasi

    SÜMEYRA CAN

    Yüksek Lisans

    İngilizce

    İngilizce

    2014

    OnkolojiFatih Üniversitesi

    Biyomedikal Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. HAŞİM ÖZGÜR TABAKOĞLU