Alt alanlı IMRT planlarında tedavi planı kalite kontrollerinin EPID ve 2D Array ile değerlendirilmesi
Alt alanlı IMRT planlarında tedavi planı kalite kontrollerinin EPID ve 2D Array ile değerlendirilmesi
- Tez No: 336831
- Danışmanlar: DOÇ. İSMAİL ÖZBAY
- Tez Türü: Yüksek Lisans
- Konular: Onkoloji, Oncology
- Anahtar Kelimeler: radyoterapi, EPID, 2D Array, IMRT, kalite kontrol, Doz-cevap ilişkisi-radyasyon, Neoplazmlar, Radyografi, Radyometri, Radyoterapi-bilgisayar yardımlı, radiotherapy, EPID, 2D Array, IMRT, quality control, Dose-response relationship-radiation, Neoplasms, Radiography, Radiometry, Radiotherapy-computer assisted
- Yıl: 2013
- Dil: Türkçe
- Üniversite: İstanbul Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Temel Onkoloji Ana Bilim Dalı
- Bilim Dalı: Tıbbi Radyofizik Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Çetinkaya, E. (2013). Alt alanlı IMRT Planlarında Plan Kalite Kontrollerinin EPID ve 2D Array ile Değerlendirilmesi. İstanbul Üniversitesi Sağlık Bilimleri Enstitüsü, Temel Onkoloji ABD. Yüksek Lisans Tezi. İstanbul. Bu çalışmada, 20 IMRT tedavi planının kalite kontrolleri, iki farklı dozimetrik kalite kontrol (QA) sistemiyle değerlendirilmiştir. 20 IMRT planının(219 alan (25 non-split + 97x2 split)) QA?i Array ve EPID ile gantri, kolimatör ve masa açıları 00?de yapıldı. Ayrıca IMRT planlarının 10?u EPID?de gerçek plan parametreleriyle de tekrarlandı. Array?le yapılan QA datası Verisoft?da analiz edilmiştir. Varian aSi500 EPID?le yapılan QA dataları ise hem kendi programı Portal Dosimetry?de hem de Verisoft?da analiz edildi. Her iki programda da analizlerde %3-3mm ve %4-4mm gamma analizi kriteri kullanılmıştır. Verisoft?daki analizlerde %0, 5 ve 10 suppress, lokal doz, maksimum doz; Portal Dosimetry?de ise ROI: none, field+1, %5 ve %10 threshold seçenekleri ayrı ayrı denenerek etkisi incelenmiştir. Kullanılan IMRT planları Eclipse TPS?nde AAA algoritmasıyla hazırlanmıştır. Planlar, alt alanlı (subfield) baş-boyun planlarıdır. Analizler Beam by Beam (BbB) ve Composite analiz teknikleriyle değerlendirilmiştir. 120 MLC?li Varian DHX (RapidArc) linak cihazı kullanılmıştır. Çalışma sonucunda, aynı IMRT planlarının hem Array hem de EPID ile QA?leri yapılınca Array QA?lerinin referans doz haritasıyla uyum yüzdesinin daha yüksek olduğu bulunmuştur. EPID QA?in analizinde seçilen kriterler analiz sonucunu önemli oranda etkilemektedir. Array QA ile EPID QA?i karşılaştırırken analiz programının farklı olmasından kaynaklanan etkiyi ortadan kaldırmak için EPID QA?in doz haritaları Verisoft?da da değerlendirilmiş ve sonuçların Array QA ile yakın olduğu görülmüştür. Plan parametrelerini sıfırlayarak QA yapma ile gerçek değerleriyle yapma arasında fark görülmemiştir. Ayrıca IMRT QA?i BbB yapmak ile Composite yapmak arasında da önemli fark yoktur. Ancak lokal dozda değerlendirme ile maksimum dozda değerlendirme arasında fark vardır.
Özet (Çeviri)
Cetinkaya, E. (2013). Evaluation of quality assurance of IMRT plans consisting of sub-fields with EPID and 2D Array. İstanbul University, Institute of Health Science, Department of Basic Oncology, M. Sc. Thesis, Istanbul. In this study, quality assurances of 20 IMRT treatment plans were evaluated with two different dosimetric quality control (QA) systems. QA of 20 IMRT plans (219 (25 non-split + 97x2 split) fields) whose plan parameters are at 0 degree, were applied with 2D Array and EPID. Also, 10 of IMRT plans were repeated in EPID with original plan parameters. QA carried out with array were analyzed with Verisoft software. Besides, QA carried out with Varian aSi500 EPID were analyzed with both Portal Dosimetry software which is its own analysis software and Verisoft. In the analysis of both programmes criteria of gamma analysis with %3-3mm and %4-4mm was used. In analysis of Verisoft, %0, %5 and %10 suppress, local dose and maximum dose were examined, while choices of ROI: none, field+1, %5 and %10 thresholds were applied and examined in Portal Dosimetry. IMRT plans were prepared in Eclipse TPS with AAA algorithm. The plans consist of head-neck plans with sub-fields. Analysises were evaluated with both per-field and composite analysis tecniques. Varian DHX (RapidArc) with 120 MLC was used as linac. As a result of this study, Array QAs? consistency percentage with reference dose map was found to be higher when the same IMRT plans? QAs were made with both Array and EPID. Criterias chosen for analysis of EPID QA have considerable effect on analysis results. While comparing Array QA with EPID QA, EPID QA?s dose maps were evaluated in Verisoft to eliminate the effect arising from analysis program?s being different and it was seen that results were similar with Array QA. It was also found that there was no difference between QAs made through resetting plan parameters and QAs made with real values. Besides, there is no significant difference between making QA IMRT BbB and making it Composite. However, there is difference between evaluating in local dose and evaluating in maximum dose.
Benzer Tezler
- Elektromagnetik dalgaların rezistif yan duvarlı bir oluktan saçılımı
Electromagnetic wave scattering from a rectangular groove with resistive walls
DEMET SEVİL ARMAĞAN ŞAHİNKAYA
Doktora
Türkçe
2003
Elektrik ve Elektronik Mühendisliğiİstanbul Teknik ÜniversitesiElektronik ve Haberleşme Mühendisliği Ana Bilim Dalı
PROF. DR. EREN ERDOĞAN
- Spherical gravitational shock waves
<küresel gravitasyonel şok dalgaları
S.KAYHAN ÜLKER
Yüksek Lisans
İngilizce
1997
Fizik ve Fizik Mühendisliğiİstanbul Teknik ÜniversitesiFizik Ana Bilim Dalı
PROF. DR. MAHMUT HORTAÇSU
- Üç alanlı güç sisteminde genetik algoritma ile otomatik üretim kontrolü
Automatic genetion control for three-area power system using genetic algorithm
BURAK TABAKOĞLU
Yüksek Lisans
Türkçe
2009
Elektrik ve Elektronik Mühendisliğiİstanbul Teknik ÜniversitesiElektrik Mühendisliği Ana Bilim Dalı
PROF. DR. AYŞEN DEMİRÖREN
- Çok alanlı sanat eğitimi yönteminin çocuğun resimsel yaratıcılığına katkıları
The contributions of multi-field art education method to the artistic creativity of children
SEVDA SUBAŞI
Yüksek Lisans
Türkçe
2014
Eğitim ve ÖğretimÇanakkale Onsekiz Mart ÜniversitesiGüzel Sanatlar Eğitimi Ana Bilim Dalı
YRD. DOÇ. DR. ENVER YOLCU
- Vankomisine dirençli enterokoklarda değişken alanlı (pulsed field) jel elektroforezi (pfge) yöntemi ile klonal ilişkinin araştırılması
Investigation of the clonal relationship with pulse field gel electrophoresis method in vancomycin resistant enterococci
KUTAY SARSAR
Doktora
Türkçe
2018
Enfeksiyon Hastalıkları ve Klinik Mikrobiyolojiİstanbul ÜniversitesiTıbbi Mikrobiyoloji Ana Bilim Dalı
PROF. DR. MUSTAFA DERYA AYDIN